ShinewayTech OFI-20A Quick Reference

Page 1
OFI-20A Optical Fiber Identifier
Quick Reference
Figure. Product Simple Figure
Function Description
Clamp Clamp and keep the fiber in a suitable location. Clamp Pushing Button Push the button up and press downward to fix the adapter head. Press the button again to loosen the adapter head. LED illuminator The LED illuminator indicates the direction of traffic. Low Battery illuminator Green: Full Battery; Orange: Low Battery which can be for current test and need to change battery; Red: Must change battery and cannot test
Selecting Adapter
Select the appropriate adaptor head according to the different types of fiber
Insert the fiber to the adapter head when using the Ø2.0 and Ø3.0 connectors
Insert the fiber to the groove on the clamp when using the Ø900 and Ø250
connectors
On/Off
Push up the clamp pushing button to turn on the unit Loosen the clamp pushing button to turn off the unit
Optical Fiber Identification
Insert the fiber to the adapter head and push the button up to lock clamp. When a CW signal passes the fiber, the LED illuminator will indicate the
traffic’s direction arrow and a relative core power readout will be displayed. If no optical signal passes the fiber, the LED illuminator is dead and the LO will be displayed in the relative core power position. Fiber identifier can also detect the presence of a 2KHz, 1KHz and 270Hz modulated signal. When a modulated signal is detected the appropriate signal LED will be illuminated, the LED illuminator will indicate the traffic direction arrow and relative core power readout will be displayed. In addition a pulsed audible tone will be heard.
Maintenance
The fiber should be put in the groove according to the specific type. Please use the cotton swabs to clean the detector surface regularly to keep it
Detector Groove on the clamp
Adapter head groove
Relative Core Power Display
LED Illuminator
Clamp
Adapter
Clamp Pushing Button
Low Battery Illuminator
Page 2
from dust. Please take out the battery when it is not in use for a period of time.
Technical Specifications
Model
OFI-20A
Identified Wavelength Range
800 - 1700 nm
Identified Signal Type
CW, 270Hz±5%, 1kHz±5%, 2kHz±5%
Detector Type
InGaAs
Adapter Type
Ø0.25 (Bare Fiber), Ø0.9 (Ø0.9 Cable )
Ø2.0 (Ø2.0 Cable ), Ø3.0 (Ø3.0 Cable )
Signal Direction
Left & Right LED indicator
Singe Direction Test Range (CW/0.9mm bare fiber)
-40dBm~+5dBm
Signal Power Test Range
-40dBm~+5dBm (CW/0.9mm bare fiber)
Signal Frequency
270Hz, 1kHz, 2kHz
Power Supply
One 9V Alkaline battery
Frequency Test Range (Average Value)
Ø0.9, Ø2.0, Ø3.0
-30~0dBm (270Hz,1KHz),
-25~0dBm (2KHz)
Ø0.25
-25~0dBm (1KHz,2KHz),
-20~0dBm (2KHz)
Insertion Loss (Typical Value)
0.8dB (1310nm), 2.5dB (1550nm)
Operating Temperature
-10~+60
Storage Temperature
-25~+70
Weight & Dimensions
200g &196*30*27mm
OFI-20A Optical Fiber Identifier