Safety Terms Used in This Manual
The WARNING sign denotes a hazard. It calls attention to a
procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personnel injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met.
The CAUTION sign denotes a hazard. It calls attention to an
operating procedure, or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or the entire product. Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met.
The NOTE sign information that may be beneficial during the use and maintenance of the instrument.
Prohibit the operation for connecting or disconnecting the device while using the power meter. The leakage of RF energy
will cause hazard damage to human being.
External power supply: This device supports an external power supply, power sensor requirements 12V DC @ 200mA, external power supply is an optional accessory.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - iv -
Connection: avoid the reverse connection to the device although it is designed with
reverse polarity protection.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - v -
CONTENTS
1. General Information ................................ ....................................... vii
1.1 Scope of This Manual...................................................................................... vii
1.2 Unpacking and Inspection ............................................................................... vii
1.3 Introduction......................................................................................................viii
2. Operation ....................................................................................... 9
2.1 Sensor Interfaces .............................................................................................. 9
2.2 RF Digital Power Meter Software .................................................................... 10
2.2.1 Driver Installation ...................................................................................... 11
2.2.2 Menu ......................................................................................................... 19
2.3 Measurement Operation ................................................................................. 34
2.3.1 Connection ................................................................................................ 34
2.3.2 Measurement ............................................................................................ 35
3. Maintenance ................................................................................. 36
3.1 Clean of Interface ............................................................................................ 36
3.2 Calibration ....................................................................................................... 36
4. Specification ................................................................................. 37
5. Warranty Information ..................................................................... 38
5.1 Terms of Warranty ........................................................................................... 38
5.2 Exclusions ....................................................................................................... 38
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - vi -
5.3 Warranty Registration...................................................................................... 39
5.4 Returning Instruments ..................................................................................... 39
5.5 Contacting Customer Service ......................................................................... 40
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - vii -
1. General Information
1.1 Scope of This Manual
Thank you for purchasing ShinewayTech product. Please read this manual carefully before using any of ShinewayTech products. Always observe the warnings and cautions appearing throughout this manual.
This manual contains the information necessary for proper operation and maintenance of ShinewayTech DPM-50 RF In Line Digital Power Meter, troubleshooting instructions as well as information regarding obtaining services.
ShinewayTech DPM-50 RF In Line Digital Power Meter is carefully assembled and undergoes a rigorous mechanical, electrical, and optical inspection prior to shipment. For detailed packing information, please refer to the packing list
Upon receiving the instrument, please check for any obvious signs of physical damage that may have occurred during shipment. Report any damage to the shipping agent or the representative of Shineway Technologies, Inc. immediately. Retain the original packing materials in case reshipment becomes necessary.
1.2 Unpacking and Inspection
This instrument has been carefully packed in accordance with standard shipping procedures. Examine the instrument for damage that may have occurred during shipment. If you find any damage or the instrument is not working, or if any of the following items are not included, please contact your representative of Shineway Technologies, Inc.
If necessary, please contact us via email: support@shinewaytech.com.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - viii -
1.3 Introduction
ShinewayTech DPM-50 has been designed for field engineers and technicians to perform power measurement in wireless network of various standards.
DPM-50 features high dynamic range, high accuracy and high stability, it works with PC monitoring software and optional handheld Monitor to perform real-time in-line monitoring on entire antenna system and saves test data for analysis and evaluation.
The typical application is to monitor the transmitter and antenna of wireless base station during network installation and maintenance, DPM-50 can fast measure
forward power of transmitter, reflected power of antenna and entire system’s VSWR.
DPM-50 is portable size; it can work with handheld Monitor which is the best solution for field test.
Features:
Handheld, Light weight and easy to use Special designed for entire antenna system installation, maintenance and
trouble shooting.
USB interface for real time monitoring and data transfer Straight forward test result display
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 9 -
2. Operation
This part introduces the basic operation of ShinewayTechDPM-50. Please read this manual carefully for optimal operation. Should you encounter any problems during operation, you are welcome to contact the technical staff of our company or representatives.
2.1 Sensor Interfaces
1
1
2 3 4
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 10 -
1. RF Interface: N (Female)
2. External Power Input: 12V DC@200mA
3. USB Port: PC Data transfer/power supply
4. DB9: Connection to Main Control Unit (MONITOR)
2.2 RF Digital Power Meter Software
The software is for controlling DPM-50 on PC to measure power, display, save and print the result.
Function:
1USB device detection and communication.
2Select frequency to be tested.
3Measurement and data acquisition.
4Display and calculate data including:
[1]. Forward Power
[2]. Reflected Power
[3]. Load Power
[4]. VSWR
[5]. Return Loss
[6]. Rho
[7]. Temperature
5CCDF Test 6Save measured data 7Preview and print measured data
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 11 -
8)Run measurement once (Run Trigger) or run measurement continuously
(Run Continues); Continuous measurement result is displayed in curve
chart 9Gauge and curve chart range setting 10)Indication of outranged measurement data by color/sound/dialogue
window
11)Edit user information
2.2.1 Driver Installation
User should install driver when connect sensor to PC via USB cable for the first time:
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 12 -
Select Install from a list or specific location (Advanced), click Next;
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 13 -
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 14 -
Click Finish to close the wizard. And then the PC will find a new device again.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 15 -
Select Install from a list or specific location (Advanced), click Next;
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 16 -
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 17 -
Click Finish to close the wizard.
Right click My Computer on the desktop, select Properties, click Manage label, click Device Manager.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 18 -
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 19 -
If ShinewayTech RF Power Meter USB Device appears in the list, the driver is installed; otherwise please disconnect the sensor from PC, reconnect and install the
driver again.
2.2.2 Menu
After driver is installed, run the RF Digital Power Meter software and below interface appears:
Main Interface
Main Interface includes:
[1]. Menu bar
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 20 -
[2]. Tool bar
[3]. Information bar
[4]. Result display area
[5]. Property bar
[1]. Menu bar
Top Menu
Files” menu
Files” menu includes “Open File”, “Save File”, “Print Preview”, “Print” and “Exit”.
Click Open File to open CSV format file.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 21 -
Open File
Click Save Files to save file. Input the file name (Default: DataFile.csv), the file format is CSV” which can be opened with Office Excel.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 22 -
Save File
Click Print Preview to preview the report and data to be printed.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 23 -
Print Preview
Click Print to configure printer settings and print data.
Print
Click Exit to exit the software.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 24 -
Device Info Menu
Click Device Info and the menu will roll up and down to check device information.
Settings” menu
“Settings” menu includes “Select Frequency”, “Options”.
Click Select Frequency to select the frequency.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 25 -
Select Frequency” roll down
Select Frequency” while roll up
Click Settings menu to input/select the settings.
Test Item” submenu under “Setting”
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 26 -
“Plot range”: “Max “,” Min “indicates the maximum and minimum vertical axis (Y axis) of the trace area under the continuous measurement mode.
“Limits Settings”: “Max”, “Min” indicates the maximum and minimum axis of the six dials under the continuous measurement mode, the interface 6 to be able to measure the results of circular pointer icon displays the maximum and minimum coordinates.
Enable Limit Check: If selecting this item, the measurement result will be shown in red when the measurement exceeds the setting range (greater than Max. or less than Min.). If not selecting this item, the measurement result will be always shown in black.
Enable Limit Warning: If selecting this item, there will be a popup window when the measurement exceeds the setting range (greater than Max. or less than Min.). If not selecting this item, there will not be a popup window what ever the measurement is. (Note: this feature is only available under triggered measurement mode. It is not available under continuous measurement mode. To ensure the continuity of measurement under continuous measurement mode, the system disable this feature.).
Warning Sound: If selecting this item, there will be a warning tone when the measurement exceeds the setting range (greater than Max. or less than Min.). If not selecting this item, there will not be a warning tone what ever the measurement is. (Note: this feature is only available under triggered measurement mode. It is not available under continuous measurement mode. To ensure the continuity of measurement under continuous measurement mode, the system disable this feature.).
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 27 -
Basic Info submenu under Setting
Operator, Sample Type, Sample S/N will be shown in the printing report.
Interval indicates the interval time between two consecutive measurements under continuous measurement mode. The minimum interval is 1 second.
Last Time indicates the total time under continuous measurement mode.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 28 -
“Time Span”: Select the certain item to fit for different modulation type.
Time span
Modulation Type
150us
CW Burstb.w.>300us, Voice Band AM, FM, Phase Modulation
15us
CW Burstb.w.>30us, Voice Band AM, FM, Phase Modulation
1.0us
CW Burstb.w.>2us,GSM,50kHz AM, DQPSK (14π,symbol rate<24k/s)
0.1us
CW Burstb.w.>0.2us,GSM, CDMA, WCDMA, DQPSK(1/4π,symbol rate<200k/s), DAB/DVB-T
Help Menu
Click Help to get further inform for the version information.
About
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 29 -
3) Tool Bar
The items in Toolbar are similar with the Main Menu.
Click Run Trigger to run a measurement. The measurement result will be displayed in the GUI by two ways: number and dial. The number will be red while it is out of the setting range, and be green while it is within the setting range. The date trace on the bottom of the main screen will hide.
Result Display Area
Result displayed:
[1]. Forward Power [2]. Peak Power [3]. Reflected Power Load Power
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 30 -
[4]. VSWR [5]. Return Loss [6]. Crest Factor [7].CCDF
Note: Equations:
[1]. Crest Factor (Logarithm value) = Peak Power (Logarithm) - Forward Power (Logarithm) [2]. VSWR = (1 + Rho) / (1 - Rho) [3]. Return Loss (Logarithm) = Forward Power (Logarithm) - Reflected Power (Logarithm)
Click Run Continues to run a measurement. The interval and last time value can be set in the Setting menu. The measurement result will be displayed in the GUI by two ways: number and dial. The number will be red while it is out of the setting range, and be green while it is within the setting range. The data will be point by point added in the historical trace. The user can click on the pages under the trace to check the data trace for the different measurement items.
Curve chart
4) Info
The device information, Frequency, Setting are shown in Info column.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 31 -
Info”
“Device Info” shows USB device information, if the USB device does not access the computer, then the information will be “------”.
Frequency”: The user can set the desired frequency. There are two ways:
pre-defined frequency and user setting frequency. If the input value beyond the system's frequency range, a pop-up window will display as below.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 32 -
Setting column shows the user's current settings, measurement display range, measurement limits, which can be set by users. If the input value exceeds the acceptable range, the system will show an error pop-up window.
“CCDF”: Set the threshold value and display the real-time CCDF value. Click “set” button, a dialog window is shown as below. Input a threshold value and click OK button.
CCDF Threshold Setting”
After setting the threshold, click “ Run Trigger” or “Run Continues” button, the CCDF value display real-time.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 33 -
CCDF Display Area”
5) Result Display Area
Result Display Area:
Measurement results are shown with the trace under continuous
measurement mode.
Result Display Area
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 34 -
6) Status Bar
Status Bar”: the status information of software is shown.
Status Bar”
Status bar displays the following: [1]. Mouse position at the coordinates of historical trace [2]. Count of successes and failures of measurements [3]. USB device access status to computer [4]. Device temperature
2.3 Measurement Operation
2.3.1 Connection
Prohibit the operation for connecting or disconnecting the device while using the power meter. The leakage of RF energy will cause harm to human being.
Measuring and Connecting Map
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 35 -
2.3.2 Measurement
Turn on the PC software after the system connection is completed.
1) In Information Bar to set the frequency, setting frequency method:
For
selecting a common used frequency band, click the select frequency
drop-down menu below, select the frequency.
For user define frequency, input the value in the blank under User Frequency.
2 Click or to make a measurement. 3 Change the frequency
Click to stop the measurement. Refer to the above steps to change the measurement frequency.
Click or make a measurement.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 36 -
3. Maintenance
3.1 Clean of Interface
Please follow the safety rules before cleaning:
Be sure the device is power off before cleaning. Non-compliance under the control, regulation or procedure may result in
hazardous radiation exposure.
To prevent electric shock, keep the device away from the mains before
cleaning. Use dry or slightly damp cloth to clean the external case, do not clean inside.
Device should be repaired d by qualified technician while damaged. Sensor N connector should be put on protective cover to prevent damage
when not in use.
3.2 Calibration
DPM-50 series is recommended to calibrate every three years. Please contact ShinewayTech service center or distributor for the calibration.
The device may have errors in the performance without the proper maintenance.
Performance degradation due to the following reasons:
Distance measurement error increases;
Linearity error;
Received power falls outside the normal range of power measurement.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 37 -
4. Specification
Model
DPM-50AP
Frequency Range
300-4200MHz
Average Power Range
100mW-200W
Peak Power Range
100mW-500W
Dynamic Range (dB)
≥33
Insertion Loss (dB)
≤0.1
VSWR
1.05-99.9
Crest Factor
0 ~ 12dB
CCDF
0.1% ~ 100%
Directivity
≥30 (<3GHz); ≥28 (>3GHz)
Average Power Measurement Accuracy
±4%+0.05W (0℃ ~+15℃ or +35℃~+50℃ increase 3%)
Peak Power Measurement Uncertainty
Pulse Width > 200 µs: ±7% 1 µs < Pulse Width < 200 µs: ±10% Pulse Width < 1 µs: ±15% Pulse Width < 0.5 µs: ±20%
Impedance
50Ω
Connector
N (Female)
Data Interface
USB
DPM Interface
DB9
General Specifications
Power Supply (Monitor)
NiMH Battery/ AC Adaptor
Operating Temperature
-10℃ ~ 50
Storage Temperature
-20℃ ~ 70
Relative Humidity
0~85% (Non-condensing)
Weight
480g (Sensor)/ 900g (MONITOR)
Dimensions (H×W×T)
130×(95)×124×34mm (Sensor); 220×110×70mm (MONITOR)
* Specifications subject to change w ithout notice
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 38 -
5. Warranty Information
5.1 Terms of Warranty
All ShinewayTech products are warranted against defective material and workmanship for a period of one (1) year from the date of shipment to the original customer. Any product found to be defective within the warranty period would be repaired or replaced by Shineway Technologies Inc. free of charge.
In no case will Shineway Technologies, Inc. liabilities exceed the original purchase price of the product.
5.2 Exclusions
The warranty on your equipment shall not apply to defects resulting from the following:
Unauthorized repair or modification Misuse, negligence, or accident Consumptive parts (e.g electrodes)
Shineway Technologies, Inc. reserves the right to make changes to any of its products at any time without having to replace or change previously purchased units.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 39 -
5.3 Warranty Registration
A warranty registration card is included with the original shipment of equipment. Please take a few moments to fill out the card and mail or fax it to the local Customer Service Center of Shineway Technologies, Inc. to ensure proper initiation of your warranty term and scope of your warranty.
5.4 Returning Instruments
To return instrument for reasons of yearly calibration or other, please contact the local Customer Service Center of Shineway Technologies, Inc. to obtain additional information and a RMA# (Return Materials Authorization number). And describe briefly reasons for the return of the equipment, to allow us offer you more efficient service.
To return the instrument in the case of repair, calibration or other maintenance, please note the following:
Be sure to pack the instrument with soft cushion like Polyethylene, so as to
protect the shell of the instrument.
Please use the original hard packing box. If use other packing material,
please ensure at least 3 cm soft material around the instrument.
Be sure to correctly fill out and return the warranty registration card, which
should include the following information: company name, postal address, contact, phone number, email address and problem description.
Be sure to seal the packing box with exclusive tape. Be sure to ship to your representative or the agent of the Company in a
reliable way.
DPM-50 RF In Line Digital Power Meter User's Manual
Shineway Technologies, Inc. - 40 -
5.5 Contacting Customer Service
Please check our web site (www.shinewaytech.com) for updates to this manual and additional application information. If you need technical or sales support, please
contact local Shineway Technologies Customer Service.
Shineway Technologies (China), Inc.:
Address: Fl.7, Zhongtai Plaza, No.3 Shuangqing Rd, Haidian District, Beijing,
China
Postal code: 100085
Tel: +86-10-62953388 Fax: +86-10-62958572
Email: support@shinewaytech.com WEB: www.shinewaytech.com
THANK YOU FOR CHOOSING
SHINEWAY TECHNOLOGIES!
DOC. P/N: MAN-DPM50-EN-V120518
Loading...