SHINCO SPS5-14H User Manual

SPS5-14H
Portable Air Conditioner
User’s Manual
Thanks for choosing this high quality portable air conditioner. Please read the Manual carefully before operation. In case of any problem, please contact professional maintenance personnel in time.
CONTENT
User Knowledge
Special Warning
Product Introduction
Main Parts and Components Control Panel and Remote Controller
Product Operation
Placement and Installation Operation Method
Clean and Maintenance
Drainage Method Maintenance
...............................................6
............................................14
..............................................15
.................................................15
..................................1
.........................................3
...............................7
..................................9
...................8
Common Failures and Diagnosis
Intelligent Error Detection Trouble-shooting
Machine Parts Parameters
Fuse Parameter Machine Dimensions
Service Information
.............................................18
.............................................19
........................................19
................................18
.................................20
USER KNOWLEDGE
The meaning of this user manual is shown bellow.
Please prohibit such operation for your health and safety with your family.
For the sake of health and safety of your family, you must do the following.
MATTERS NEEDING ATTENTION
This machine is for household use
.
only
Do not stack items around the machine so as not to impede the air exchange.
This machine is for indoor use only Please place it in dry environment.
Do not place heavy objects on the machine to avoid damage to the machine.
1
Do not operate the unit with wet hands or in a humid environment.
Please wipe the machine with a soft cloth. Do not use wax, thinner or irritant detergent.
稀释剂
Please clean the filter regularly and recommend cleaning once every two weeks.
Please unplug the power supply if the machine is not used for a long time.
For your health, please don not drink condensed water discharged from machine.
Non professionals should not disassemble or repair the machine without authorization.
2
IMPORTANT SAFETY TIPS
Please not use damaged power cord or power cord plug, do not insert power cord into loose socket.
Do not modify or extend the power cord.
Do not damage or use damaged or unknown type of power cord. Please ensure that the voltage used meets the requirements before use.
It is recommended to use grounding receptacles when running this unit.
Do not plug or unplug the power cord with wet hands, this operation has the
risk of causing electric shock.
When pulling the power cord, please pinch the plug and do not pull the power cord.
3
Do not control the opening and closing state of the machine by plugging the power plug.
Please turn off the machine before you pulling the plug.
Do not share a power outlet with multiple high-power electrical appliances.
If the machine makes a strong noise, smell or smoke, please turn off the machine immediately and pull the plug to check the cause.
Please keep the machine away from the heat source and avoid direct sunlight.
Do not press heavy objects on the power cord, so as to prevent the power cord from being crushed and cause electric shock.
4
Don’t insert your fingers or any hard object to wind guide bar of the air outlet.
Do not let water enter the electrical part of the machine.
If water enters the machine, shut it down immediately and pull out the plug, then contact the professional maintenance personnel for repair.
When the gas leak occurs, please open the windows first, ensure the air circulation, then run the machine.
If you need to wipe, clean, move the machine or replace the machine parts, please turn off the machine and unplug the power plug first.
The appliance user must be eight years of age. Weak people, people with weak sensory abilities or low psychological quality must be supervised and used when they understand the correct use methods and harmfulness. Children are prohibited from playing. Children must be cleaned and maintained under supervision.
5
SPECIAL WARNING
Place the A/C on even ground and install it vertically, so as to ensure normal operation of the compressor.
Don’t use the A/C beside gasoline or any other inflammable liquid.
The A/C should be at least 19.7in. away from surrounding objects. Keep air inlet and outlet smooth.
n.i7.91
19.7in.
19.7in.
Don’t use spraying agent and other solvent or flammable substances near the A/C; otherwise, its plastic may deform and electric parts may be damaged.
6
PRODUCT INTRODUCTION
1
2
3
4
5
6
MAIN PARTS COMPONENTS
Handle
Air inlet (Down)
Control Panel
Air outlet louver
Castor
Remote controller
3
4
1
2
5
7
6
7
8
9
10
11
12
Air outlet(Up)
Hot air outlet
Drainage nozzle
Air outlet grille
Exhaust duct assembly
Window sealing plate assembly
10
8
9
11
12
7
CONTROL PANEL AND REMOTE CONTROLLER
1
2
3
4
Mode
Cool
Fan
Dry
Heat
High
HR
Mid
Low
Fan
Power key
Press the key to turn ON/OFF the A/C.
Speed key
Press the key to choose high/middle/low speed.
Temperature/ time adjusting key
Press the key at cooling mode or heating mode to increase/reduce the setting temperature; press it at timing mode to adjust timing ON/OFF time; press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature.
Mode key
Press the key to choose cooling, heat,fan,dry.
Timer
8
7
5
6
7
Timer key
Press the key at standby mode to set ON time. Press this key at ON mode to set OFF time.
Temperature/ time display window
This window displays the adjusted temperature and time.
Switch key
Press the key to switch and .
8
Swing key
Press this button or press the speed key and timing key simultaneously to turn on / off the swinging function.
8
PRODUCT OPERATION
PLANCEMENT AND INSTALLATION
Placement
Place the machine on the horizontal floor near the window. In order to maintain good air circulation and make the machine get the best performance, there should be at least
space around it.
.
Installation
19.7in.
Exhaust joint
Window sealing plate assembly
Exhaust duct assembly
Exhaust pipe
Flattened mouth
Window sealing plate
Window sealing plate
Hand pull button
9
Step 1:
Measure window size; Adjust the length of the window sealing plate to make it fit with the size of the window.
When the length of the window seal plate is fixed, the length of the sealing plate is fixed by hand pull button.
Locking
opening
Step 2:
Install the fixed window seal on the window.
Step 3:
Swirl the exhaust pipe assembly (exhaust fitting end) into the rear panel outlet (counterclockwise).
10
Small gap
First insert
Step 4:
Clip the exhaust pipe assembly (exhaust port end) into the window seal panel assembly and screw it up.
Then slide locking.
Overall effect diagram after assembly
11
Incorrect installation
It’s important to keep the exhaust duct smooth. Incorrect installation will affect work of the A/C.
Prevent the exhaust duct from sharp bending.
Ensure air can flow smoothly in the duct.
Warning
The exhaust duct is designed especially for this model. Don’t replace or lengthen it; otherwise, it will result in failure.
Notice:
Max. developed length of the exhaust duct is 59in. It’s better to shorten it while use and keep it horizontal while installation.
REMOTE CONTROLLER
Please install the battery correctly before using the remote control. The specific steps are as follows:
1
Slide the battery cover on the back of the remote control.
2
Insert 2*AAADC1.5V) new batteries and ensure that batteries, and ensure that the battery electrodes are installed correctly when inserted.
3
Fit the battery cover in place.
Notice:
1
The remote controller can only use AAA(DC1.5V) batteries. Do not use rechargeable batteries or other types of batteries.
2
Replace two batteries when replacing batteries. Do not mix old and new batteries.
3
If the air conditioner is not used for a long time, please remove the battery in the remote control.
12
Warning:
1
Do not use batteries if there is any leakage.
2
Chemicals in batteries may cause burns or other health hazards. If the liquid flows to the skin or clothes carelessly, please wash them with clean water immediately; if you eat it carelessly, rinse your mouth with clear water immediately, and then go to the hospital for further examination.
13
OPERATION METHOD
Cool mode
·
When the A/C enters cooling mode automatically or cooling mode is selected after power ON, the cooling indicator lamp lights up.
Press Up/Down key to adjust setting temperature (60 F~ 86 ) .
·
Press Speed key to choose High/Mid/Low speed.
·
F
Fan mode
·
When pressing mode key or choosing Fan mode by pressing the remote controller, the wind indicator lamp lights up.
·
Press Speed key to choose High/Mid/Low speed.
Temperature can’t be set.
·
Dry mode
When pressing mode key or choosing dry mode by pressing the remote
·
controller, the dehumidification indicator lamp lights up.
·
Take off the water plug of the desiccant nozzle as shown on the right, insert the water guide pipe, and put the other end of the water guide pipe into the water container or drainage channel.
·
When entering the dry mode, the the room temperature is greater than 63 F Thereafter the compressor is controlled according to the
following rules: when the room temperature is
less than 59 F, the compressor is turned off; when the room temperature is raised to
more than 59 F, the compressor is restarted
(the compressor restart must satisfy the three-minute delay protection function).
In dry mode, the fan is defaulted to run at low speed,
·
and wind speed can’t be adjusted
Temperature can’t be set.
·
Use hint: when dry function is used, the exhaust pipe assemblyshould be removed, otherwise it will cause that dehumidification effect is notobvious and "FL" full of alarm display appears.
compressor is started if
Heating mode
When the A/C enters heating mode automatically or heating mode is selected
·
after power ON, the cooling indicator lamp lights up.
·
Press Up/Down key to adjust setting temperature
Press Speed key to choose High/Mid/Low speed.
·
14
(60 F~ 86 ) .
F
Timer mode
In standby state, press the Timer key to set ON time. Press Up and Down keys to set
·
ON time (1~24H), and the timer indicator lamp lights up.
·
In ON state, pressure the timer key to set OFF time. Press Up and Down keys to set OFF time (1~24H), and the timer indicator lamp lights up.
CLEAN AND MAINTENANCE
DRAINAGE METHOD
If the internal vessel is full of water, the display screen will display “FL”, and the compressor stops working automatically. At this point, the water needs to be discharged. The specific steps are as follows:
1
Unplug the power cord and take down the exhaust duct assembl
2
Move the air conditioner to the right place.
Pull off the drain at the drain and drain the water inside
3
the machine.
4
Re plug the water plug.
Reinstall the exhaust duct assembly and start the machine.
5
MAINTENANCECE
I
CLEANING
Unplug before cleaning.
1
Wipe with soft semi-dry cloth. Don’t use chemical reagent,
2
such as benzene, alcohol and gasoline etc; otherwise surface of the A/C and even the whole A/C will be damaged.
y.
3
Prevent water from spattering in the A/C.
15
FILTER SCREEN
It is suggested to clean the filter every two weeks. If the indoor air quality is poor, the cleaning frequency should be improved appropriately. Because the filter screen is blocked by dust, it will reduce the efficiency of air conditioning. The specific cleaning steps are as follows:
1
2
3
4
According to the direction of the chart, the lower intake grille is first taken out and the filter screen is removed.
Clean the filter with clean or warm water (about 104 F) which has been added with neutral detergent, then put it in a cool place to dry
The filter screen cleaned and dried will be re installed.
Restart the machine and run properly.
.
If the filter screen is not too dirty, just use the vacuum cleaner to absorb the dust.
If the filter is dirty, clean the filter with clear water or warm water. The temperature is about 104 F.
Notice:
Do not use water with excessive temperature (suitable temperature is about 104 F) or
1
irritant detergent (such as alcohol, gasoline, benzene, etc.) to clean the filter.
2
To avoid deformation of the filter, the cleaned filter should be kept away from the heat source and put in dry air to dry naturally.
Do not run machines without filters.
3
16
SEASONAL CLEANING
If the A/C will not be used for a long time, Please follow these
steps to maintain it
2
1
Pull out the water plug to drain.
Run the A/C in fan mode for 2H till the inside is dry.
2
Turn off the A/C and unplug.
3
Wash the filter screen and reassemble it.
4
Dismantle the exhaust duct and keep it properly.
5
6
Take the battery from the remote control.
Cover the A/C with a plastic bag and place it at a dry place.
7
If you haven't used it for a long time, please pay attention to the following points when you use it again
Confirm whether water plugs and filters are installed.
1
Check if the power cord is intact. If there is any damage, do not use it.
2
Reinstall the remote battery.
3
Reinstall the other components according to the installation instructions.
4
17
COMMON FAILURES AND DIAGNOSIS
INTELLIGENT ERROR DETECTION
Error-detecting code
E1 E2
E4
The following table lists the common faults and maintenance methods of this series of portable A/C. When the machine is in abnormal operation, the following table can be used for simple diagnosis and maintenance. If it still can not be solved, please contact professional maintenance personnel.
TROUBLE
The A/C doesn’t work
Multi-functional defection Error of the coil’s temperature sensor
Error of indoor temperature sensor Anti-freezing protection: temperature of the coil is too low and the whole A/C is off. When temperature excesses 46 F ,the protection is released and previous working state is recovered.
TROUBLE-SHOOTING
CAUSE
No display
The display panel displays “FL”
Time OFF function is started
Direct sunlight
Reset circuit breaker on AC cord
Restart the A/C after power off and draining, then it will become normal
The A/C can be restarted 3 minutes after being turning off Draw the curtain
SOLUTION
The A/C starts frequently
Big noise of the A/C
The compressor doesn’t work
Doors and windows keep open; there are lots of people or heat source in room
Filter screen is very dirty
Air inlet or air outlet is blocked
The A/C is placed unevenly
Its delay protection is started
18
Close doors and windows, remove heat source
Clean or replace it
Remove the stem
Place it at even and firm ground, avoid shaking
Wait for 3min, turn on after temperature decreases
MACHINE PARTS PARAMETERS
FUSE PARAMETERS
Specification:
Voltage:
Current:
Φ5×20mm
250VAC
3.15A
MACHINE DIMENSIONS
28.5in.
14.1in.
17in.
The above technical parameters are subject to change without notice.
19
Meaning of crossed –out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.Contact you local government for information regarding the collection systems available.If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.
TO OBTAIN WARRANTY SERVICE:
Toll number :833-3SHINCO
Working Time : From 8:30AM to 5:00PM Monday through Friday Standard (Eastern) Time
WARRANTY PERIOD:
Labor: 1 Year from the Date of Purchase.
Parts: 1 Year from the Date of Purchase.
YOAU Electric Co., Ltd reserve rights to upgrade products without user notice.
20
Loading...