SHIMPO Instruments FGS-100EH, FGS-100EL User manual

Vertical Force Test Stand
FGS-100E-H/L
Operation Manual
90000
Please read carefully before using this product.
   Read carefully "Safety Precautions" and Handling Instructions.
Use appropria
NIDEC-SHIMPO CORPORATION
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Before Installation, Operation or Maintenance, be sure to read carefully this Operation Manual and use the equipment as
directed. Use the equipment after carefully reading all the caution items, safety information, and other discriminations. In this User's Manual, the Safety Awareness Items are divided into three different categories: "Danger", "Warning" and
"Caution".
DANGER
WARNING
CAUTION
This symbol indicates if you ignore the contents mentioned and improperly operate, it may
lead to serious injury from a potential 󳞛re.
This symbol indicates a potential dangerous situation that could produce a serious injury if improperly handled.
This symbol indicates a potential situation that could produce a minor injury or damage to
material if it is improperly handled. However, depending upon the situation, there could be a
possibility that it may cause more serious results.
Protection categories are explained and separated by the following symbols.
Proceed with Caution
Not Allowed -Prohibited
Mandatory- Must Follow
WARNING
Heavy! Take suf󳞛cient care while handling. Ensure stand is placed on a 󳞜at, level,
Do not operate in areas where explosive gases or vapors may be present.
stable surface that can support the unit.
Do not touch the running, inner parts.
Keep appendages and loose clothing away from running, moving parts.
Do not attempt to inspect or perform maintenance on the unit with the electrical cord connected to a power source.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
1
2
CAUTION
If a loud noise is created from the unit
during operation, check the mounting of the gauge or level of the stand. If noise
persists, contact the factory.
Hold power plug while removing the power cord. Do not pull or put tension on
the cord. Doing so could result in cord
damage and electric shock.
Use only matching electrical sockets. Do not alter the power connector in order to 󳞛t an unmatched socket. Shock or 󳞛re
could result.
Mandatory
Do Not Use in Below Mentioned Locations.
① Where water, oil or chemicals may come in contact.
② Where there is ample amounts of dust. ③ Where condensation may emerge.
Do not install in a high humidity
environment or near where water may be present. Electric shock may occur if water is encountered.
Do not scratch, damage, cut, over-turn, pull, twist, or bundle the power supply cord. The electric power cord may be broken and may cause electric shock, 󳞛re
or accident.
Con󳞛rm that the power supply is the same voltage rating as the displayed voltage
rating on the unit.
Take care that the Force Gauge Cable is not caught in the moving parts. This can be prevented by properly securing the
cable so that it cannot come into contact
with the moving parts.
④ Where a 󳞛re or explosion may exist or occur.
Mount the Force Gauge to the Test Stand
⑤ Where vibration of machinery exists. ⑥ Where temperatures will go outside
o
F to104 oF (0oC to 40oC).
of 32
Do not clean with 󳞜ammable liquids such as
thinner and gasoline.
with the Test Stand's power switch in the
off position.
Do Not adjust the limit knobs while the Test Stand is moving.
Ensure that the green earth grounding wire of the power cord is grounded.
Installation of Digital Force Gauge FGV Series
While installing the Digital Force Gauge FGV Series to the Test Stand FGV Function Setting F06 Outer Parts Output Switchover Setting is to be performed by the Over Load Output (over) Setting. If setting is performed using the Comparator Output, then with the Force Gauge Over Load (Excess
Load), the Stand does not Stop.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
3
Index
1. Before Use
1.1. Force Gauge Installation
1.2.Inspection of Included Accessories
2. Speci󳞛cation
3. Product Diagram
4. Operation Panel Functions.
5. Prepara
5.1. Installation of Force Gauge.
5.2. Cable connection to the Force Gauge.
tion
6. Operation.
6.1. Basic Movement
6.2. Speed unit change
6.3. Changing Mode
6.4. Movement Mode
6.4.1 Jogging Mode. (JOg)
6.4.2 Manual Mode. (MAU)
6.4.3 1 Cycle Mode. (SIg)
4 4
4
5
6
6
8
8 8
9
9
10
11
11
12
12
13
6.4.4 Continue Mode. (CON)
6.5. Speed
7. Display Error
8. Outer Dimensions.
9. Trouble Shooting.
14
15
16
17
18
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
4
1. Before Use
1.1. Force Gauge Installation
This Shimpo Instruments FGS-100E Test Stand is to be installed with a Shimpo Instruments Digital Force Gauge Series FGV and is able to perform all types of Load Tests. Related to its execution from installation to measurement, utilize the following procedure. If encountering issues, check the Trouble Shooting section of this manual.
Con󳞛rmation before Use.
1.2.Inspection of Included Accessories
Name of Product.
FGV Connecting Cable (2m).
Power Supply Cable
Cable Clip
Socket Bolt (M4 x 8) for Installing Gauge to Sta
Socket Bolt (M6 x 12) for Test Jig Installation.
Allen Key Spanner for M6t.
Allen Key Spanner for M4
Operation Manual
Guarantee
Installation of Force Gauge
Trouble Shooting.
Quantity.
1 1 1 4
2 1 1
1
1
Connection.
Issues
Measurement Mode Separate Operation Method.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
5
2. Speci󳞛cations
Series FGS-100E
Display
Model
FGS-100E-L FGS-100E-H
Low Speed Speci󳞛cations High Speed Speci󳞛cations
Measuring Load 500N(50kgf) (112.4 lbf)
Load Resistance 500N(50kgf) (112.4 lbf)
Forwarding Speed 6-180mm/min(0.23-7.00in/min) 20-600mm/min(0.78-23.60in/min)
Speed Settings Set the Speed through Operation panel.
Speed Accuracy ± 5%
Stroke 400mm (15.75in)
Display Parts LCD 3 Digits indicates movement speed, Operation Mode.
Movement Speed 6-180mm/min(0.23-7.00in/min) 20-600mm/min(0.78-23.60in/min)
Operation Mode Manual (MAU), Jogging (JOG), 1 Cycle (SIG), Continuous (CON).
Input Over Load Input Stops by FGV Over Load Signal
Measurement Table 93 × 150mm(3.66 × 5.91in)
Temperature Range 0 ~ 45° (No Condensation)  32 to 113° F
Power Supply AC100 ~ 230V ± 10%
Weight Approx.20kg(40.1lbs)
Outer Dimensions 220 × 680 × 358mm (8.7 × 26.8 × 14.1in)
Corresponding Force Gauge FGE-0.5 ~ 100 FGV-0.5 ~ 100
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
6
3. Product Diagram
Cable Clip
Upper Adjustable Limit Knob
Force Gauge
Measuring Table
Emergency Stop Switch
Operation Panel
Force Gauge Mounting Bracket
Lower Adjustable Limit Knob
Backside Diagram
Fuse
Power Switch
Power Cable Outlet
FGV Connecting Cable
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
7
4. Operation Panel Functions
5
1
2
3
4
No.
1
2
3
4 5
Names
UP
DOWN
MAX
MODE
LCD
10
6
8
11
7
1
Function
Set Movement Speeds for Manual (MAU), JOGGING (JOg) Modes and during PUSH/ PULL Operation in 1 Cycle (SIg) and Continuous (CON) Modes. inch/min Mode : Pressed once , the movement speed increases/decreases by 0.01
if pressed continuously , it cha
mm/min Mode : Pressed once , the movement speed increases/decreases by 1 ,if
pressed continuously , it changes at the rate of 10 .
Overrides to the maximum speed value possible of the Stand's motor when pressed. Once released, the speed returns to the previous set value.
Scroll through the Modes (MAU)
Displays the condition of Movement Speed, Mode, Alarms. Etc.
nges at the rate of 0.1 .
6
7 8
9 10 11
LCD Normal Display
1) Sub Display Parts:
Presently selected Opera
it Position, Over Load condition, or when the Emergency Stop is ON, the Operation Mode and all the Indicators
Lim
light
-up alternately
Limit Position Reached in Operation Mode LMT Flashes
② Over Load Occurrence in Operation Mode OVR Flashes ③
When Emergency Stop is ON in Operation Mode EMg Flashes
PULL
PUSH
STOP
MAX_LED
PULL_LED
PUSH_LED
.
Starts the Operation of PULL Direction
Starts the Operation of PUSH Direction
Stops Test Operation
Pressing MAX Key, when the Movement Speed is at Maximum, the Lamp lights.
During PULL Operation it 󳞜ashes
During PUSH Operation it 󳞜ashes
tion Mode is displayed at the top Sub-Display of LCD.
2) Main Display Parts: The set movement speed value is indicated in the main display.
Sub Display (Operation Mode)
Main Display (Movement Speed)
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
8
5. Preparation
5.1. Installation of Force Gauge
※ Attach the Force Gauge to the Mounting Bracket.
Using the Allen wrench spanner provided in the accessories, remove the installation bolts connecting
the Test Stand and the Force Gauge Mounting
Bracket
Attach the Force Gauge to the Force Gauge Mounting
Bracket.
With Installation Bolts, secure to the bracket.
With the 4 Installation bolts, install the Force Gauge and Mounting Bracket to the Test Stand
Possible Force Gauges to install on the FGS-100E is the FGV Series Force Gauges
5.2. Cable connection to the Force Gauge.
Insert the attached connecting cable to the back-side connector of FGS-100E Stand and connect the
other side to the corresponding connector of Force Gauge.
If this communication cable is not connected, the automatic stop function of the Stand due to a Force
Gauge sensor over load condition may not be available. In order to protect the Force Gauge, ensure
proper connection.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
9
6. Movement
6.1. Basic Movement
Take suf󳞛cient care while aligning, as there is potential of catching a hand, 󳞛nger or clothes in the Stand which would cause injury.
Test Stand Power Cord is connected to outlet as well as Force Gauge power Adapter. Turn on Force Gauge.
Test Stand Power Cord is connected to outlet as well as Force Gauge power Adapter. Turn on Force Gauge.
Once on, the display will indicate the model number, then will show the speed setting as shown below.
(Example) Tension Test of Wire.
MODE (Measuring Method) Setting.
Select the Movement Mode, matching to your required test needs.
Movement Mode
Press the PUSH Key or PULL Key to cycle through Manual, Jogging, 1Cycle or Continuous movement.
Manual Mode Display.
MAU JOg SIg
Jogging Mode Display. 1 Cycle Mode Display.
Power Supply.
Wedge Chuck
(OPTIONAL)
Crimped Terminal.
Continuous Mode Display.
CON
Start Measuring
With the PUSH or PULL Key, Measurement can be started. For details refer to the Movement Mode Operation described later. Load Tests as follows can be performed.
Press Test - Tensile Strength Test - Weld Strength Test - Peel off Test - Absorption Power Test Resistance Power Test - Uncapping (Seal) Test -
Punching Test.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
10
6.2. Speed unit change
① When changing the operation speed to inch/mm from mm/min
a) Power OFF
Turn ON the sta Keep pressing the “MAX”
er the stands turn ON, the display shows its model name
b) Aft
nd while holding down the “MAX” key
key until the display shows JOG mode
.
*Still keep pressing “MAX” key at this point
c) To JOg mode
Then, the stand goes to JOg mode. The stand shows default value of operation speed.
Low speed High speed
Then, t
he unit change is 󳞛nished.
:  0.30inch/min
:  0.80inch/min
② When changing the operation speed to mm/min from inch/mm
a) Power OFF
Turn ON the sta Keep pressing the “MAX”
nd while holding down the “MAX” key
key until the display shows JOG mode
.
OFF
FGS
Jog
OFF
b) Aft
er the stands turn ON, the display shows its model name
*Still keep pressing “MAX” key at this point
c) To JOg mode
and goes to JOg mode and shows default of operation
The st
speed.
Low speed High speed
The unit cha
:  6mm/min
:  20mm/min
nge is 󳞛nished
FGS
Jog
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
11
6.3. Changing Mode
To perform a load test manually, press the PUSH or PULL key.
Examples.
Press the PULL Key once, if you want to move the Force Gauge
up to the top Limit Knob
Press the PUSH Key once, if you want to make move the Force Gauge down to the bottom Limit
If the Mode Selection Switch (Operation Panel) is pressed, the Movement Mode changes by turns as follows. Utilize by selecting the Movement making Mode. The present Movement Mode is displayed at
the upper centre of LCD.
Jog
Mode
Jogging Mode Display.
6.4. Movement Mode
Select out of 4 varieties of Movements
Manual Mode
MAU
Jogging Mode
MODE
Jog
Press the PUSH or PULL Key once, the Stand proceeds at the preset speed until hitting the Upper or Lower Adjustable Limit Knobs or if the STOP button is
pressed.
Stand moves as long as PUSH or PULL key remain pressed.
JOg
MAU
Mode
Manual Mode Display.
MODE
MAU
SIG
Mode
1 Cycle Mode Display.
SIG
MODE
CON
Mode
Continuous Mode Display.
CON
MODE
1 Cycle Mode
SIg
Continuous Mode
Press the PUSH or PULL key once. The Stand will proceed towards the Limit Knob in the PUSH/PULL direction. It will hit that Limit, then move in the opposite direction all the way to the opposing Limit Knob.
Press the PUSH or PULL key once. The Stand will cycle between the Limits continuously until the STOP key is pressed.
CON
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
12
6.4.1 Jogging Mode (JOg)
Jogging Movement is performed
While the PUSH Key or PULL Key is pressed, it moves towards PUSH (downward) or PULL (upward). If you release the PUSH Key or PULL Key the movement stops.
The speed changes by UP or DOWN Key. The speed setting of JOg Mode and MAU Mode become common. Speed Variation is also possible during the movement while PUSH/PULL
are depressed.
Movement Mode
Jog
Speed Setting
6.4.2. Manual Mode (MAU)
If the PUSH Key or PULL Key is pressed once, it moves downward (PUSH) or upward (PULL). When the Limit Knob is reached, it stops. The STOP key can at any time stop the process.
MAU
Upper Limit Knob
Stops by Upper Limit Switch Knob
LMT
PULL
PUSH
MAU
Lower Limit Knob
Stops by Lower Limit Switch Knob
Change speed by UP, DOWN Key. The speed setting of JOG Mode and MANU Mode becomes common. Speed Variation is also possible during the movement.
Movement Mode
MAU
Speed Setting
LMT
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
13
6.4.3 1 Cycle Mode (SIg)
Contents
1 Cycle (Compression. Expansion) Movement is performed.
Between the Limits, the stand repeats movement for 1 time cycle only. The Stand will proceed towards the Limit Knob in the PUSH/PULL direction. It will hit that Limit, then move in the opposite direction all the way to the
opposing Limit Knob.
If either PUSH Key or PULL Key is pressed, the stand starts moving toward that respective direction. STOP key can instantly end the test.
Stops by position of Adjustable Limit Knob.
After stopping for 1 second, it turns back and moves
SIG
Upper Limit Knob.
towards PUSH Direction.
SIG
SIG
PULL Speed
PULL
Lower Limit Knob.
Upper Limit Knob.
PULL Speed
LMT
LMT
PUSH Speed
Stops by Limit Switch in ON position.
Stops by Limit Knob position.
LMT
PUSH
PUSH Speed
LMT
SIG
Lower Limit Knob.
Stops by Limit Knob position.
After stopping for 1 second, it turns back and moves towards PULL Direction.
Change speed by UP, DOWN Key. SIG Mode and CON Mode Speed Setting are commonly used. During movement, Speed variation is not possible. When no movement is occurring (at idle), the display shows movement Mode and the latest operated speed. When the movement starts, the respective memorized movement speed is displayed.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
14
6.4.4 Continuous Mode (CON)
Stand performs the continuous repeated movement in between the Adjustable Limit Knobs.
When the PUSH Key or PULL Key is pressed, the stand moves towards that respective direction, hits the knob, then continues on in the opposite direction. This process will continue and cycle until the STOP Key is pressed.
Stops at Limit Knob position.
After stopping for 1 second, it turns back and moves
CON
Upper Limit Knob.
towards PUSH Direction.
CON
CON
PUSH Speed
PULL Speed
PULL
PUSH Speed
Lower Limit Knob.
Upper Limit Knob.
PULL Speed
PUSH
LMT
LMT
Stops at Limit Knob position.
After stopping for 1 second, it turns back and moves towards PULL Direction.
Stops at Limit Knob position.
After stopping for 1 second, it turns back and moves towards PUSH Direction.
LMT
LMT
CON
Lower Limit Knob.
Stops at Limit Knob position.
After stopping for 1 second, it turns back and moves towards PULL Direction.
Change speed by UP, DOWN Key. SIg Mode and CON Mode Speed Setting are commonly used. During movement, speed variation is not possible. When no movement is occurring (at idle), the display shows movement Mode and the latest operated speed. When the movement starts, the respective memorized movement . Speed is displayed.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
15
6.5 Speed Setting
The Movement Mode becomes either 1Cycle Mode (SIg) or Continuous Mode (CON) and during the Stop Movement, while pressing the MAX Key, it enters/turns into the Speed Setting.
Setting the PUSH Direction Movement Speed by UP/DOWN Key, if the MAX is pressed, it turns into the PULL Direction Movement Speed Setting.
Setting with the UP/DOWN Key, if the MAX is pressed, then the two-way movement speed is memorized.
In case the setting is to be cancelled during adjustments, press the STOP Key and it will be cancelled.
MAX
Setting of PUSH Movement Speed
PUS
Speed of the PUSH Direction movement could be set by UP/DOWN Key.
MAX
Setting of PULL Movement Speed
After memory input, the display returns to normal.
PUL
MAX
Speed of the PULL Direction movement could be set by UP/DOWN Key.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
16
7. Display Error
LMT
LMT
OVR
OVR
EMg
ALM
Lower Limit Knob is reached. Upper Display, LMT and MODE 󳞜ash alternately. Main Display becomes PUSH.
Upper Limit Knob is reached. Upper Display, LMT and MODE 󳞜ash alternately. Main Display becomes PULL.
The Force Gauge's sensor PUSH over load was detected. Upper Display alternately lights-up with
OVR and MODE.
The Force Gauge's sensor PULL over load was detected. Upper Display alternately lights-up with
OVR and MODE.
Emergency Stop Switch was pressed. Upper display alternately lights-up with EMG and
MODE.
A motor abnormality was generated. Upper display 󳞜ashes ALM.
In normal Limit movement, this Display is generated.
In normal Limit movement, this Display is generated.
Release opens the movement and load. Con󳞛rm the load given to the Force Gauge and con󳞛rm whether
the rated capacity of the installed Force Gauge is appropriate.
Release opens the movement and load. Con󳞛rm the load given to the Force Gauge and con󳞛rm whether
the rated capacity of the installed Force Gauge is appropriate.
After avoiding the abnormal condition, put the Emergency Stop Switch to OFF.
Switch the Power Supply OFF for 1 minute, then
turn ON. If again the same Error is generated,
then enquire with your local agent or contact our customer service.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
17
8. Outer Dimensions
Cable Clip
150
93
172150 70
13 57
4-φ4.5
Force Gauge Installation Bracket Parts Details
2075
20
40
(188)
3-M6P=1.0Depth9
(115)
Force Gauge Installation Bracket.
Force Gauge (sold separately).
MeasuringTable
115
188
9
129 3 Stroke:400
220 358
(93)
3030
(150)
MeasuringTablePartsDetails.
680
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
18
9. Trouble Shooting
Following is the explanation of the examples of general troubles and respective solutions. If you still have issues, then please enquire with your local agent or contact our customer service.
Phenomenon.
Even though Power Supply is ON, the LCD
does not display.
Arm / Alarm do not work.
"ALM" lights up at LCD Display. Motor Alarm
"EMg" lights up at LCD Display.
(Emergency Stop Switch ON)
"OVR" lights up at LCD Display.
(Overload detection)
Trouble Solution Method.
Con󳞛rm whether AC100~240V Power Supply is provided to the Power Supply Cord.
Supply AC100 ~ 240 V
Con󳞛rm whether the Stand Back Side Fuse is interrupted.
In case it is interrupted, con󳞛rm whether any abnormalities exist in the Power Supply, replace the Fuse.
For Fuse Replacement, use FGMB 250V 5A PBF Fuji Terminal (Appropriate goods)
Con󳞛rm whether excessive load exists.
Remove Stand Load
Con󳞛rm whether Emergency Stop Switch is ON.
After con󳞛rming that there is no abnormal condition and con󳞛rming that there is no problem, then put the Emergency Stop Switch to OFF.
Con󳞛rm the Over Load of Force Gauge.
Remove the excessive load of Force Gauge.
"LMT" lights up at LCD Display.
(Upper or Lower Limit knob
detection).
Reaches to Limit Switch.
Change the position of Limit Switch.
The Guarantee Card of this product is attached with the product. For contents of the Guarantee, please see the back of Guarantee Card.