Shimpo Instruments DT-5TXR Data Sheet

The DT-5TXR Panel Meter with Optional Output Modules
monitoring when combined with a compatible in-line sensor. Loaded with features found in more expensive units, the DT-5TXR Panel Meter is extremely versatile with selectable inputs. The DT­5TXR is fully scalable and possesses three selectable modes allowing it to measure RPM/linear speed/rate, elapsed time and process time. Each panel meter accepts a variety of signal inputs from any sensor providing an NPN, contact, sine wave, or square wave such as pulse generators, proximity sensors, photoelec­tric sensors, magnetic sensors and NPN OC transistors. Typical applications can range from machining operation timing, rate of change monitoring such as on a conveyor, elapsed time of oven curing etc. with any variety of compatible sensor inputs desired. The DT-5TXR panel meter also accepts various output modules, enabling it to output data for analysis, record keeping or assist in controlling the process through a separate control device. Up to two modules can be accepted simultaneously, offering an enor­mous number of combinations and options.
is an economical unit for speed and process time
DT-5TXR Panel Meter
with Optional Output Modules
Features
• Accepts up to two output modules allowing voltage, current, BCD, NPN & relay output combinations for control or remote process monitoring
• Highly accurate (± 0.008% ± 1 digit) makes ideal for process control and analysis
• Large 6 digit LED display plus two smaller 6 digit secondary displays allow easy viewing from greater distances
• Scalable programming gives user the flexibility to set up and monitor virtually any process
• Selectable update time allows operator to speed up/slow down display changes to facilitate process
• Wide power range (85 - 264VAC, 50/60Hz) eliminates need for having to purchase and wire an additional power transformer. Low voltage models available
• Great versatility with multiple sensor input capability in one unit: NPN open collector, contact and square or sine wave sensor inputs
• Front cover protection eliminates accidental bumping of keypad to incorrect program
• IP66 front cover protection keeps water out, enables usage in compatible plant wash-down operations
• DC power source output to power compatible sensors saves money by eliminating need for separate power supply
• Selectable decimal point enables higher resolution display potential 1/8 DIN size panel cut out permits easy, industry-standard mounting
DT-5TXR Specifications
Measuring Range
Display Range
Scalable Yes (with outputs, see modules)
Accuracy
Display Update Time 0.2, 0.5, 1, 2, 5, 10, 15, 30, 60 sec.
Input No. of P/R 1 to 9,999 (programmable)
Input Signal Characteristics
Sensor Power Supply 12 VDC (150 mA)
Power Requirement
Ambient Temperature 32 - 113°F (0 - 45°C)
Product Weight 0.66 lb (300 g)
Package Weight 0.95 lb (430 g)
Dimensions 5.27 x 3.78x 1.89” (134 x 96 x 48 mm)
Warranty 1 year
Included Accessories
10 - 99,999 rpm (at 1 p/r),
0.2 - 30,000 rpm (at 60 p/r)
Tachometer/Rate Meter: 0 - 999999 with selectable decimal point. Elapsed Time: 0:00:00 - 9:59:59 or
0.00- 999.99 sec. Process Time: 0:00:00 - 0:59:59 or
0.00 - 999.99 sec
Tachometer/Rate Meter & Elapsed Time: ± 0.008 % ± 1 digit
Process Time: ± 0.008 % ± 1 digit
NPN open collector input: max. fre­quency 100 kHz / Contact input: max. frequency 20 Hz / Square wave input: max. frequency 30 kHz
- Sine wave input (magnetic pickup): max. frequency 10 kHz
85 - 264 VAC (50/60 Hz) Optional (9 - 35 VDC at 1 W also available)
Mounting adapters & screws, decal sheet
Ordering Details
DT-5TXR
DT-5TXR-DC
DOP-BCD BCD output module, 36 Pin Connection
DOP-CPTR Relay output module, terminal block connection
DOP-FVC
DOP-FVTR
DOP-RMTR Ratio input module, terminal block connection
DOP-TRC
DOP-TRTR
Note: For Factory Assembled Panel Meter with Output Modules, Add Module to end of DT-5TXR Part and remove DOP. For two modules, only 1 36-Pin Module and 1 Terminal Block connection module can combine. Example: DT-5TXR-CPTR-FVC Panel Meter, 100-240VAC Power with Relay Output Ter­minal Module & 36-Pin Analog Output Module
Panel Meter with Output Module Capability, Selectable inputs, 100-240 VAC Power
Panel Meter with Output Module Capability, Selectable inputs, 9-35 VDC Power
Analog output module (4-20mA & 0-1, 0-10, 1-5 VDC), 36-pin connection
Analog output module (4-20mA & 0-1, 0-10, 1-5 VDC), terminal block connection
NPN open collector output module, 36 pin connection
NPN open collector output module, terminal block connection
Accessories
BI2-S12
DJ2-G
Proximity Sensors
Retro­Reflective Photo Sensors
Rotary Pulse Generators
Magentic Pick-up Sensors
Slot Type Sensor
MCS-3109
SE-G
MCS-625
MCS-655
LS-S50MLR
RE1B-60C
RE1B-600C
RE1B-1000C
RE2B-30C
RE2B-60C
RE2B-600C
FPM-RE1B
MP-10
3030AN
CABLE-3030
3070­XP12010
CM-SR21
CBL-75ANL
NPN (NO) sinking output 1.5 kHz frequency, LED indication, 6.5’ (2 m) cable, 0.08” (2 mm) sensing distance, NEMA 6 (IP67) rating
NAMUR output, 3 kHz frequency, zero-sensing capability, 6.5’ (2 m) cable, 0.08” (2mm) sens­ing distance, NEMA 6 (IP67) rating
NPN (NO,NC) output, 300 Hz frequency,
0.32” (8 mm) sensing distance, 6.5’ (2 m) cable, NEMA 6 (IP67) rating, for use in high vibration areas
Square wave output, 8 kHz frequency, LED indication, 18” (0.46 m) cable, 0.04” (1 mm) sensing distance,
Photo sensor with NPN sinking output, 250 Hz activating frequency, 10’ (3 m) cable 1” to 3’ (25 to 914 mm) operating range
Photo sensor with NPN sinking output, 333 Hz activating frequency, LED status, 10’ (3 m) cable, NEMA 4 (IP65), 1” to 3’ (25 to 914 mm) operating range for light or dark activation.
Laser sensor with NPN/PNP (NO,NC) outputs,
1.5 kHz frequency, LED indication, 6’ (1.8 m) with quick disconnect connection, NEMA 6 (IP67) rating
Single logic output (Logic “1” …supply volt­age minus 2.5V or more, 10mA (max) / Logic “0”… less the 0.4V, 30mA max.), 60 pulses/ rev., 5000 rpm max., 10’ (3 m) cable
Single logic output (Logic “1” …supply volt­age minus 2.5V or more, 10mA (max) / Logic “0”… less the 0.4V, 30mA max.), 600 pulses/ rev., 3000 rpm max., 10’ (3 m) cable
Single logic output (Logic “1” …supply volt­age minus 2.5V or more, 10mA (max) / Logic “0”… less the 0.4V, 30mA max.), 1000 pulses/ rev., 1800 rpm max., 10’ (3 m) cable
Dual logic output (90° out of phase) for quadrature applications. Same logic as the RE1B Series. A zero position output for shaft position reference. 30 pulses/rev., 5000 rpm max., 1.6’ (.49 m) cable.
Dual logic output (90° out of phase) for quadrature applications. Same logic as the RE1B Series. A zero position output for shaft position reference. 60 pulses/rev., 5000 rpm max., 1.6’ (.49 m) cable.
Dual logic output (90° out of phase) for quadrature applications. Same logic as the RE1B Series. A zero position output for shaft position reference. 600 pulses/rev., 3000 rpm max., 1.6’ (.49 m) cable.
12” circumference wheel for use with RE1B and RE2B pulse generators
Sine wave output from change in magnetic to non-magnetic, change in voltage proportional to magnetic flux intensity over time, range of
0.01” (0.25 mm) typical clearance, 10’ (3 m) cable
Sine wave output from change in magnetic to non-magnetic, change in voltage proportional to magnetic flux intensity over time, range of
0.01” (0.25 mm) typical clearance, Amphenol connector
Optional cable for 3030AN
Sine wave output from change in magnetic to non-magnetic, change in voltage proportional to magnetic flux intensity over time, range of
0.01” (0.25 mm) typical clearance, 10’ (3 m) cable Stainless steel housing, explosion-proof ATEX approved: II 2 GEExm II T3
For less dense materials that allows beam to penetrate through, NPN or PNP output with a 0.08” (2 mm) gap range, NEMA 4x (IP65) housing.
Optional cable for CM-SR21 16.4’ (5 m)
Loading...