Shimpo ST-329BL Operation Manual

ST-329BL LED Stroboscope Array Operation Manual
Use in flammable environments is prohibited. Use in this manner may result in fire or explosive.
Don’t look directly into the LED light Source. This may result in eye in­jury.
Don’t use or store in the following environments. Direct sunshine con­densation, dust or caustic.
Do not alter, or modify of improperly. Such action may cause damage and void warranty.
Operate with 0-35°C (32-95°F), 35-85% RH. Use outside of this range may alter operation of the unit.
Case may become excessively hot when used continuously for more than 2 hours. Mount unit on a tripod or other fixed device.
SHIMPO INSTRUMENTS
The ST-329BL is a permanent mount blacklight stroboscope
array utilizing super bright, CREE high powered LED lamps. The ST-329BL’s LED array provides a bright, stable black light over a wide measurement range with a lifetime far exceeding xenon lit stroboscopes. The ST-329BL arrays are available in several standard sizes from 9.25” (235 mm) to 65” (1650 mm) in length. Custom sizes are available upon request. The arrays are easi­ly mountable on production equipment. An optional mounting adapter kit is available to aid in array installation. A separate con­trol enclosure is connected with 6.5’ (2 m) cable to the array. Op­eration is simple with the 8 button keypad and large, backlit LCD display. Phase shift, flash duration, plus flash rate are all quickly adjustable via the control. The unit can work off user programmed flash frequency or from a remote sensor’s signal which will auto­matically adjust to corresponding process fluctuations.
The ST-329BL is designed for speed and frequency measure­ments in the printing, packaging, textile, automotive, cable, medi­cal industries in various applications.
SPECIFICATIONS
Flash Rate Range: 60 to 120,000 FPM Accuracy: 0.01%±1 digit of F.S. @ 77° F (25°C) Lamp Lifetime: Approximately 3~5 years depending on usage. Display: Backlit LCD Resolution: 60 ~12,000 FPM = 0.1 FPM; 12,001~120,000 FPM
= 1 FPM
Flash Duration: 0.1°- 2.5° Phase Shift: 0-359° Power Requirement: 100-120 VAC (Optional 220 -260 VAC
upon request).
Input Signal: 12 V Pulse Input; M-12, 3 Pin Input Signal Range: 60-120,000 FPM Input Pulse Width: Over 50 µs Input Signal Flash Delay: 0-999 ms; 0-359° Temperature Limits: 32-95°F (0-35°C) Humidity Limits: 35 to 85% RH Enclosure: Control - ABS; Array - ABS window & aluminum
frame Mounting: Control: Magnetic mount to included bracket; Array: Flanges for use with 6 mm bolts. Mounting bracket kit available separately.
Enclosure Rating: IP65 - Control & Array Dimensions: Length (See chart on page 6) x 6” (153 mm) x 3.5”
(90 mm)
Approvals: CE Warranty: 1 year Included Accessories: 6.5’ (2 m) AC power cord, 9.8’ (3 m)
control/array connection cable (5 pin)
Operation Panel Located on Control Enclosure POWER: Power on and off. MODE: Select mode of operation or Parameter Menu: Internal/
External/Parameter Settings
SET: Adjust Phase Shift; In Parameter Menu scroll through param-
eter settings, Store setting values.
x2: Multiplies the flash rate/frequency by a factor of 2. 1/2: Divides the flash rate/frequency by a factor of 2. RATIO: Adjusts flash duration (flash pulse width) in Internal/Ex-
ternal modes.
“+”: Advance image forward 3 degrees at a time in internal mode.
In parameter setting mode, adjusts setting values.
“-”: Retard image backwards 3 degrees at a time in internal mode.
In parameter setting mode, adjusts setting values.
Dial: Set flash rate or frequency. CW: Increase flash rate/frequen-
cy. CCW: Decrease flash rate/frequency. (Turn dial quickly to drastically change value; Turn dial slowly to change value by 1 digit.) In parameter setting mode, CW or CCW rotation chang­es the setting value.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Dial
INSTALLATION
Mounting
The control box is easily mounted to a magnetic surface with its included magnetic bracket. Pull off bracket from back of control box and mount through screw/bolt holes to surface. Then attach control box to magnetic mounting bracket.The LED array may be mounted with its mount flange located on each end. 6 mm holes are on the flanges. For additional mounting hardware to aid array mounting the MK-320 mounting kit provides brackets that easily connect to the array’s flanges.
Connections
Connect power cable to power connection on underside of array.
Connect control box to array with provided 5 pin connecrion ca­ble. Note: Attach cable to bottom left side connector (5 pin) on control enclosure.
M-12, 3 pin connector on bottom right side of control enclosure is input control signal connection for external control.
FUNCTION INSTRUCTIONS
Mode Selection - To switch between INTERNAL, EXTERNAL and
PARAMETER menu, press and release the MODE key. For details about Parameter setting mode, please refer to Parameter setting menu section.
Internal Flashing Mode
LCD DISPLAY
Display Parameter Icons
Sub Data Display
Main Data Display
•Flash rate value will be displayed in internal flashing or Exter­nal trigger mode.
•Display will indicate “P” or “LCD” (in ON/OFF setting of LCD backlight) in *Parameter setting mode.
*For details about Parameter setting mode, please refer to Pa­rameter setting mode.
Sub Data Display
Internal Mode
•Phase Shift will indicate degrees of phase shift in internal flash­ing mode. To change the degrees of phase shift, press + or ­keys. The display will reflect the cumulative angle of phase shift.
Main
Data
Units
Flash Rate (Frequency Setting) in Internal Mode -
You can set the flash rate by turning the dial in the center of the unit. To increase the flash rate, turn the dial in the clockwise direc­tion. To decrease the flash rate, turn the dial in the counter-clock­wise direction. For small adjustments, turn the dial slowly. For quick adjustments, rotate the dial quickly. The flash rate range and resolution will be different according to the selected measur­ing range.
One function of a stroboscope is to provide a “stopped” image of a rotating target when the flash rate of the stroboscope has matched the rotational speed of the target object. The strobo­scope will show a single image when the flash rate is set to a lesser multiple of the true RPM (1/2,1/3,etc.) When the flash rate is increased to a higher multiple (2,3,etc.), multiple images will appear. To find the true RPM of the target object, reduce the flash rate to a lower multiple until only one image appears.
•The flash duration time will be displayed when the RATIO key is pressed. The flash duration time can then be increased or decreased with the dial from 0 to 2.5 (0~2.5°) degrees.
External Mode
• In external trigger mode, the display will show the settings of delay time. For details about changing these settings, please see external trigger mode section.