Shimpo ST-320BL-2, ST-320BL-1, ST-320BL-1-230V Instruction Manual

ST-320BL LED Stroboscope Array Operation Manual
Use in flammable environments is prohibited. Use in this manner may result in fire or explosive.
Don’t look directly into the LED light Source. This may result in eye in­jury.
Don’t use or store in the following environments. Direct sunshine con­densation, dust or caustic.
Do not alter, or modify of improperly. Such action may cause damage and void warranty.
Operate with 0-35°C (32-95°F), 35-85% RH. Use outside of this range may alter operation of the unit.
Case may become excessively hot when used continuously for more than 2 hours. Mount unit on a tripod or other fixed device.
The ST-320BL is a portable or permanent mount stro­boscope. Utilizing super bright high-powered black light CREE
LED lamps, these stroboscopes are perfect for UV ink printing applications. The ST-320BL’s LED array provides a bright, stable strobe light over a wide measurement range with a lifetime far exceeding xenon lit stroboscopes. Operation is simple with the 8 button keypad and quick rate adjustment dial, combined with large, backlit LCD display. Phase shift, flash duration, plus flash rate are all quickly adjustable. The unit can work off user adjusted flash frequency or from a remote sensor’s signal which will auto­matically adjust to corresponding process fluctuations.
The ST-320BL is designed for speed and frequency measure­ments in the printing, packaging, textile, automotive, cable, min­ing, steel, chemical, optical and medical industries in various ap­plications.
SHIMPO INSTRUMENTS
SPECIFICATIONS
Flash Rate Range: 60 to 120,000 FPM ; 1-2000 Hz Accuracy: 0.01%±1 digit of F.S. @ 77° F (25°C) Lamp Lifetime: Approximately 3~5 years depending on usage. Display: Backlit LCD Resolution: 60 ~12,000 FPM = 0.1 FPM; 12,001~120,000 FPM
= 1 FPM; 1~200 HZ = 0.01 Hz; 201~2000 = 0.1 Hz
Flash Duration: 0.1°- 2.5° Phase Shift: 0-359° Power Requirement: ST-320BL-1: 100-120 VAC; ST-320BL-2:
Rechargeable Battery.
Battery: (ST-320BL-2) Lithium DC 10.8V 2000mA Battery Life: (ST-320BL-2): Approx. 12 hrs depending on settings Input Signal: 12 V Pulse Input; 3 pin M-12 Input Signal Range: 60-120,000 FPM (1-2000 Hz) Input Pulse Width: Over 50 µs Input Signal Flash Delay: 0-999 ms; 0-359° Temperature Limits: 32-95°F (0-35°C) Humidity Limits: 35 to 85% RH Enclosure: Aluminum & ABS Mounting: 1/4-20 UNC Thread Enclosure Rating: IP54 Product Weight: ST-320BL-1: 1.85 lb (0.84 kg);
ST-320BL-2: 1.98 lb (0.90 kg) Package Weight: ST-320BL-1: 4.40 lb (2.0 kg); ST-320BL-2: 5.73 lb (2.6 kg)
Approvals: CE Warranty: 1 year Included Accessories: Carrying Case, ST-320BL-1: 6.5’ (2 m)
AC power cord; ST-320BL-2: Power Recharging Adapter with cord.
Operation Panel Located on Control Enclosure POWER: Power on and off. MODE: Select mode of operation or Parameter Menu: Internal/
External/Parameter Settings
SET: Change Units (FPM to Hz); In Parameter Menu scroll through
parameter settings, Store setting values.
x2: Multiplies the flash rate/frequency by a factor of 2. 1/2: Divides the flash rate/frequency by a factor of 2. RATIO: Adjusts flash duration (flash pulse width) in Internal/Ex-
ternal modes.
“+”: Advance image forward 3 degrees at a time in internal mode.
In parameter setting mode, adjusts setting values.
“-”: Retard image backwards 3 degrees at a time in internal mode.
In parameter setting mode, adjusts setting values.
Dial: Set flash rate or frequency. CW: Increase flash rate/frequen-
cy. CCW: Decrease flash rate/frequency. (Turn dial quickly to drastically change value; Turn dial slowly to change value by 1 digit.) In parameter setting mode, CW or CCW rotation chang­es the setting value. *Dial located on side of unit.
LCD Display
Display Parameter Icons
Sub Data Display
Main Data Display
•Flash rate value will be displayed in internal flashing or Exter­nal trigger mode.
Units
Main
Data
FUNCTION INSTRUCTIONS
Mode Selection - To switch between INTERNAL, EXTERNAL and
PARAMETER menu, press and release the MODE key. For details about Parameter setting mode, please refer to Parameter setting menu section.
•Display will indicate “P” or “LCD” (in ON/OFF setting of LCD backlight) in *Parameter setting mode.
*For details about Parameter setting mode, please refer to Pa­rameter setting mode.
Sub Data Display
Internal Mode
•Phase Shift will indicate degrees of phase shift in internal flash­ing mode. To change the degrees of phase shift, press + or ­keys. The display will reflect the cumulative angle of phase shift.
•The flash duration time will be displayed when the RATIO key is pressed. The flash duration time can then be increased or decreased with the dial from 0 to 2.5 (0~2.5°) degrees.
External Mode
• In external trigger mode, the display will show the settings of delay time. For details about changing these settings, please see external trigger mode section.
Internal Flashing Mode
Changing Units of Measure in Internal Mode - To change the
measuring units from FPM to Hz, press and release the SET key. Units will alternate with each press and release.
Flash Rate (Frequency Setting) in Internal Mode ­You can set the flash rate by turning the dial in the center of the unit. To increase the flash rate, turn the dial in the clockwise direc­tion. To decrease the flash rate, turn the dial in the counter-clock­wise direction. For small adjustments, turn the dial slowly. For quick adjustments, rotate the dial quickly. The flash rate range and resolution will be different according to the selected measur­ing range.
One function of a stroboscope is to provide a “stopped” image of a rotating target when the flash rate of the stroboscope has matched the rotational speed of the target object. The strobo­scope will show a single image when the flash rate is set to a lesser multiple of the true RPM (1/2,1/3,etc.) When the flash rate is increased to a higher multiple (2,3,etc.), multiple images will appear. To find the true RPM of the target object, reduce the flash rate to a lower multiple until only one image appears.
2
Loading...