SHIMPO DT-601CG User Manual

Reversible integrating counter with calculation function
DT-601CG
Operation Manual
97600A
Read this manual thoroughly prior to usage.
NIDEC-SHIMPO AMERICA CORPORATION / 1701 Glenlake Avenue Itasca, IL 60143 USA / Phone: (800) 237-7079 / Fax: (630) 924-0342
www.shimpoinst.com / info@shimpoinst,com
Safety Precautions.
Be sure to read the entire instruction manual thoroughly before initial set-up, operation and maintenance.
This instruction manual provides two grades of safety warnings: "Danger" and " Caution". Be sure to follow these precautions.
Please be sure to follow all safety precautions closely.
Danger
Caution
Misusing or disregarding the instructions with this mark might cause death, severe injury, or fire.
Misusing or disregarding the instructions might cause property damage or minor injury. However, depending on the situation, it might lead to greater outcome.
Below are the explanations of each cautions to be followed.
The act indicated by this sign is strictly prohibited.
The act indicated by this sign must be executed by no means.
Caution
NEVER EXCEED SPECIFIED VOLTAGE
AVOID DIRECT SUNLIGHT
AVOID HUMIDITY AND CONDENSATION
AVOID CONTAMINATION
BE CAREFUL NOT TO GET ELECTROCUTED
DO NOT DISSEMBLE OR TOUCH INTERNAL PARTS WHILE THE POWER IS ON
NEVER EXCEED RATED LOAD
DO NOT USE IN THE PLACE WITH FLAMMABLE OBJECTS AND GAS
DO NOT DROP OR SHAKE
KEEP AWAY FROM ELECTRIC WIRE.
DO NOT TOUCH TERMINALS WHILE THE POWER IS ON.
OPTION NAME
Alarm output :
Two-points NPN output : OUT 1,2
Alarm output :
Two-points PhotoMOS relay
output : OUT 3,4
Blank
7 segments LED (RED)
RE
90° phase contrast input
RE-2T
90° phase contrast input (Input two multiplying)
RE-4T
90° phase contrast input (Input four multiplying)
AV3
Analog electric voltage output (DC1-5V, 5V-1V)
AV4
Analog electric voltage output (DC0-5V, 5V-0V)
AV5
Analog electric voltage output (DC0-10V, 10V-0V)
AI
Analog electric current output (DC4-20mA, 20-4mA)
B*
BCD output
BI*
BCD input
Blank
NPN Open collector pulse input
F
Electric voltage pulse input
V3
Sinusoidal input
N
Sine curve input
L1
Line receiver input, Single phase input
L2
Line receiver input, Double phase input
HI
High speed input (0.01Hz-120kHz)
Blank
DC12V stabilization
S24
DC24V stabilization
Blank
AC Power source (AC85-264V)
DC
DC Power source (DC12-24V)
About model type
e.g1)
Choose analog electric current output, electric voltage pulse input and DC power supply.
Model type will be
DT-601CG-AI-F-DC
e.g2)
Choose analog voltage output (0 to 5V), 90°phase contrast input, sensor power supply DC24V.
Model type will be
DT-601CG-RE-AV4-S24
INDEX
PAGE
PAGE
1. Summary
2
17. BCD output
48
2. Specification
4
18. BCD input
49
3. Meter installation
6
19. Outline dimensional drawing
50
4. Names and functions of each parts in the front.
7
20. Terminal block label drawing
51
5. Connecting terminal block
9
21. Unit label drawing
52
6. Format of input circuit
12
22. Packing specifications
53
7. Format of output circuit
13
23. About noise protection
54
8. Setting up the dip switch
14
24. Trouble shooting
55
9. Setting menu
15
10. Initially set value and initialization
16
11. Contents of each mode and setting
17
12. Setting of preset value
43
13. Setting of display offset value
44
14. Mode protect function
45
15. Adjusting analog output
46
16. Sensitivity setting of sinusoidal input and sine curve input
47
*Option B and Option B1 cannot be chosen simultaneously.
Sensor
power
Model
name
DT-601CG
Disp -
lay
90°
Input
Output Input
power
supply
supply
function
P1
1.
SUMMARY
This instrument is a Reversible integrating counter with calculation function
<Timing chart of each preset output operation>
(1)
+2stages preset operation
(2)
±Each 1stage preset operation
without
with
without
with
n = Minimum count
(Display)
OFFSET
PRESET B+n
PRESET A
PRESET A-n
OFFSET 0
(Continuous)
re-output
re-output
(Continuous)
<Boosting operation> <Down operation>
<No automatic reset> <With automatic reset>
n = Minimum count
(Display)
OFFSET
PRESET A+n
PRESET A
PRESET B+n
PRESET B 0
(Continuous)
(Continuous)
<No automatic reset> <With automatic reset>
Setting condition
OFFSET = 0 , OFFSET < PRESET A < PRESET B PRESET B = 0 , PRESET B < PRESET A < OFFSET
<Boosting/Down operation>
n = Minimum count
(Display)
PRESET A
PRESET A-n
OFFSET 0
PRESET B+n
PRESET B 0
(Continuous)
re-output
re-output
(Continuous)
Setting condition
Up/Down, and Automatic reset setting will be invalid OFFSET = 0 , OFFSET < 0 , PRESET B < OFFSET < PRESET A
P2
(3)
Batch count operation
(4)
+1stage plus secondary output operation
<Output condition of each preset output>
(Display)
<Boosting operation> <Down operation>
(Display)
(Batch
0
Counter)
(Continuous)
Setting condition
(Continuous)
(Batch Counter) 0
(Continuous)
Automatic reset selection and re-output selection will be invalid OFFSET = 0, OFFSET < PRESET A, PRESET A = 0, PRESET A < OFFSET, PRESET B > 0 PRESET B > 0
(Display)
<Boosting operation> <Down operation>
<No automatic reset> <With automatic reset>
(Display)
(Continuous)
(Continuous)
Setting condition
Re-output selection will be invalid. OFFSET = 0, OFFSET < PRESET A, PRESET A = 0, OFFSET > PRESET A ,
99.9 > PRESET B > 0 99.9 > PRESET B > 0
In principle, 1 shot or continuous shot will be output from OUT1 to OUT4 under the condition of "count display > ( < )Preset A (PresetB) However, if +2stages preset operation or ±1stage preset operation was chosen, and used with the condition of "with re-output" or "without automatic reset", the condition will be as below irrespectively of the mode chosen (UP/DOWN).
Output set ON (continuous, 1 shot) : Count display () Preset A(Preset B)
Output set OFF (continuous, 1 shot*) : Count display <(>) Preset A(Preset B) * choosing 1shot makes output "ON"
(Continuous)
P3
2. SPECIFICATIONS
or pressing Shift key (when it exceeds, 999999 will be flushing)
ITEM
SPECIFICATIONS
(depending on the mode, select reset display)
display value after reset can be chosen from -99999 to 999999
(accept NPN open collector pulse output or actual contact output)
more than 50ms.
Selectable from xxxxx
Selectable from -99999 to 999999. When delaying the secondary output,
Judge by comparing display value and preset value
During the OUT1 alarm output is on,
Output mode
1shot period
Display
Accuracy
Scaling
Activate by RST key in the front part or ,
Display range is 0 to 999999 when selecting batch count operation
Selecting UP/DOWN mode, automatic reset re-output can be set.
(Change with ENT key)
: DC30V 50mA
: 0.12A Load voltage: AC140V
± 1stage, batch count and +1stage secondary output
selectable from 0.0 to 99.9. (the value outside the range is invalid)
OUT 1 LED (RED) will be synchronously flushing
making terminal reset input ON more than 50ms
Selectable from + side 2stages,
Selectable from 1shot or continuous
To activate Lap count and display change, turn the terminal block(2-3)
(accept NPN open collector pulse output or actual contact output)
Output from terminal block 9-6(OUT1) and 10-6(OUT2)
Two-points NPN open collector pulse output. Maximum rating
(6 is GND common) (However, with the line receiver, it will not function)
Output from terminal block 15-16(OUT3) and 17-18(OUT4)
Two-points PhotoMOS relay "a" contact output. Rated load current
(stabilization) output
Terminal block(4-3) to be ON more than 50ms
Select from Forbidden, Hold, Lap count, display exchange
Forbidden, Hold can be activated while terminal block(2-3) is ON. Toa
Line receiver 2 phase
However, duty is 50% (change with dip switch)
High speed input
(stabilization) output
Electric voltage pulse input (LOW<2V, HI=3.8 to 30V)
Sinusoidal input
Sine curve input
Line receiver 1phase
Selectable up to thousandth
Hit RST key in the front part or input reset at terminal block.
By setting the display offset value,
NPN open collector pulse input (minimum 10mA), or dry contact
Others
1x10
-9
to 9999 (selectable)
±0 (when the scaling is set to 1)
Six digits LED (characters are 14mm high and RED)
Display 1 : D1 LED (green) is on, Display 2 : D2 LED(green)
-99999 to 999999
3rd round stop (exceed the value three time, 999999 or -99999 will blink
Choose from "endless" or "display the number of time value exceeds"
(while pressing the XXX key, top 2digits will be displayed)
Output timing
Option : Type L1
Option : Type L2
Sensor input respond
Option : Type HI
Number of decimal setting
Display Range
Input signal
Option : Type F
Option : Type V3
Option : Type N
Sensor power supply
Option : Type S24
[Standard]
Display Switch
Integrated
display
overscale Display
Reset Display offset
Sensor
Input
External
Input
Preset Output
Reset Input
Hold selection input
Output terminal/ style (OUT 1, 2)
Output terminal/ style (OUT 3,4)
Preset operation
Preset value setting
Output display
Output reset
Batch count display
P4
[Option specification]
<Analog output : AV/VI option>
<BCD output : Option B>
<BCD input : Option BI>
Weight, dimensions
Operating humidity
Option : DC type
Power source
Protection grade
Body color
Case material
Others
Output terminal
Electric voltage output
Electric current output
Output accuracy
Temperature
Output respond
Mode Protect function
Output terminal
Output style
Output timing
Output action
TI (Ban-loading) signal
Output logic
Rating
Accessory
Input terminal
Input style
Input timing
Input action
Latch signal
Input logic
Rating
Accessory
Activate by Key operation (mode setting cannot be changed)
Write the each mode's set value and calculation value on to FRAM.
AC85 - 264V ( 50 / 60Hz )
DC12 - 24V ( ±10% )
0 - 50°C, 30 - 80%RH (non condensing)
400g W96xH48xD130mm ( W3.78"xH1.89"xD5.12" )
Chassis: mixed with ABS resin glass Terminal block
Black
IP66 equivalent
Terminal block cover 2pcs : main body attachment (material: acrylic,
transparent), Rubber packing (material: NBR, black), Unit rebel
From terminal block 19-20
Load resistance more than xxx
Load resistance les than xxx
Within ±0.3%(23°C) against displayed value (absolute value)
+100ppm/°C
about 50ms ( as a duration to reach 90% output change)
12bit, D/A conversion system 4000 resolution
*maximum output range: up to 102.4% of each output's maximum value.
*with analog output, calculation is done against the displayed value with
7-segments LED. This might lower the revolution below 4000 depending
on the mode setting.
Reverse the electric voltage output(AV3-5) and electric current output (AI).
*With reverse output, maximum resolution is 4000 for each output style.
From BCD option collector (37pin)
Whole digit parallel, NPN open collector pulse output
Synchronized with the display refresh
With the output level "H", shunt with GND
Output with about 25ms width when data is refreshed
Data value and TI signal, positive/negative selectable
DC30V, 10mA Max.
D-sub37 pin male (soldered type) and connector hood
From BCD option connector (37pin)
Whole digit parallel, NPN open collector pulse input
With calculation cycle
D-sub37 pin male (soldered type) and connector hood
S
while inputting latch signal, data loading is prohibited
Data value, latch signal, positive/negative selectable
outflow electricity is about 3mA when shunting each input terminals
Analog
output
Data backup
Accessory
Maximum output resolution
(over writing should be less than 10million times,about 10years conservation)
BCD
Output
BCD
Input
Reverse output
hunt the necessary digit's terminals with GND.
P5
3. METER INSTALLATION
(1) Cut the panel and insert the meter from the front part.
* When you need a splash proof,
insert the attached splash proof packing between meter and installation panel.
Meter
(2) Insert the attachment lugs in both sides of the meter.
Dimensions of panel
Installation panel
Splash proof packing
Attachement parts
(3) Slide the attachment lugs to the back(towards the terminal block side),
and turn the screw to steady the meter. (both sides)
Driver
Attachement parts
NOTE :
Make sure to horizontally installed
1. Panel has to be 1.0mm to 4.0mm thick.
2. Do not tighten the screw too much. The case might break.
3.
P6
4. NAMES AND FUNCTIONS OF EACH PARTS IN THE FRONT.
(1)
Display (A to F)
While measuring
(2)-(5) OUT1- 4 Alarm output LED
(6)
Overscale LED
(7)
Hold LED
F
(8)
Mode Key
(1)Display(Red)
(15)Display2 LED (Green) (14)Display1 LED (Green)
(12)Entre key
(7)Hold LED(Green)
(6)Overscale LED(Green)
(2)Alarm output: OUT1(Red) (3)Alarm output: OUT2(Red) (4)Alarm output: OUT3(Red) (5)Alarm output: OUT4(Red)
While setting
Synchronically flash when the OUT1 to 4's alarm was output
Flash when the value exceed 999999 or below -99999.
lash when there is external input (shunt terminal block #2 and #3)
(13)Reset key
(9)Shift key
(11)Down key
(8)Mode key
(10)Up key
Indicate the measured value of Display 1(D1) or Display 2(D2)
:
While setting modes, Display A and B indicate mode number and C to F indicate
:
setting value While setting preset value, display indicates current value
:
While setting the display offset value, display indicates current value
:
Mode
While turning on :
While measuring : Mode setting is activated when Shift key is pressed more than 2seconds
While setting : Mode number (Display A, B) can be changed over
TEST mode is activated when power is turned on while pressing this key (To escape from TEST mode, turn off the power)
while pressing this key. : Preset value setting is activated when the key is pressed more than 2seconds. : Display offset value setting is activated when Up key is pressed more than
2seconds while pressing this key.
: While setting preset value, preset number (PRESET A to B) can be switched over.
P7
(9)
Shift key
While measuring
(10)
Up key
(11)
Down key
(12)
Enter key
(13)
Reset key
(14)
Display 1 LED
(15)
Display 2 LED
*
While setting
Activate the mode setting (press with the mode key more than 2seconds)
:
Batch count number will be displayed while pressing this key.
(while selecting batch count mode)
Shift the decimal place towards right hand side.
:
While measuring
Activate display offset value (press with the mode key more than 2seconds)
:
While pressing this key, number of times exceeded the limit is indicated.
While setting
While setting
ENT
While turning on While measuring While setting
Change the value while setting (UP side)
:
Change the value while setting (DOWN side)
:
Activate or modify mode protect function
:
Format the each set values by turning on while pressing this key
:
Change the display from Display 1(D1) and Display 2(D2)
:
While setting, value will be registered with this key and return to the measuring
:
display
RST
While measuring
Switch back the display to "ZERO" or cancel the alarm output
:
Switch back the batch count display to "ZERO"
While setting
While setting, value will not be registered with this key and return to the
:
measuring display.
Will flash when displaying the value of Display1 (D1)
Will flash when displaying the value of Display2 (D2)
D1 and D2 is the one chosen by the mode 00's measuring calculation
P8
5. CONNECTING TERMINAL BLOCK
<NPN open collector pulse, electric voltage pulse, 90°phase contrast input>
Caution!
Encoder 90°phase contrast (Option)
Pulse sensor B
External Input
Power supply
Reset
Pulse sensor A
NPN Open collector pulse output
output/input(Option
Relay output
Analog output (Option)
( PhotoMOS relay )
Check power supply
(1)
1. Be careful not to get a shock while wiring.
2. Pay attention if the unit is for AC power supply type or DC power supply type
3. In case of DC power supply, carefully check +,-. Do not connect other way round
Check the names of terminals and wire them correctly
(2)
Wiring differs depending on the sensors. Refer to the wiring diagram on P11.
(3)
Maximum power supply to sensor is DC12V 100mA (optionally: DC24V 60mA), never over load. Wrong wiring might cause damages to sensor or circuit.
Make sure to tighten the screws on the terminal block
(4)
About BCD output, please refer to " BCD output" on P48
(5)
About BCD input, please refer to "BCD input" on P49
Sensor's power source should not be used for other usage.
(6)
P9
<Sinusoidal , sine curve, line receiver input>
Caution!
Sinusoidal input (Option)
Sine curve input (Option)
Power supply
Reset
BCD output/input(option)
Extra power supply
Line driver (Option)
NPN Open collector pulse output
When line receiver input
Relay output
Analog output (option)
( PhotoMOS relay )
Check power supply
(1)
1. Be careful not to get a shock while wiring.
2. Pay attention if the unit is for AC power supply type or DC power supply type
3. In case of DC power supply, carefully check +,-. Do not connect other way round Check the names of terminals and wire them correctly
(2)
Wiring differs depending on the sensors. Refer to the wiring diagram on P11.
(3)
Maximum power supply to sensor is DC12V 100mA (optionally: DC24V 60mA), never over load. Wrong wiring might cause damages to sensor or circuit.
Make sure to tighten the screws on the terminal block
(4)
About BCD output, please refer to " BCD output" on P48
(5)
About BCD input, please refer to "BCD input" on P49 With line receiver input(L1,L2) type, terminal block #9 and #10 will be input terminal.
(6)
So alarm output OUT1 and OUT2 cannot be used. Sensor's power source should not be used for other usage.
(7)
P10
<Connection diagrams for each sensor>
A.
DC three wire style pulse sensor
B. DC two wire style pulse sensor
C.
Contact output sensor
D. 90°phase contrast input
E.
Sinusoidal /Sine curve input
F. Line receiver input
G.
Three wire current modulated pulse sensor
H. Two wire current modulated pulse sensor
P11
6.
FORMAT OF INPUT CIRCUIT
(1)
Sensor input: NPN open collector pulse input or voltage contact input
(2)
Sensor input : Electric pulse input
(3)
Reset/ External input (NPN open collector pulse input)
Sensor Power
or
or
P12
7.
FORMAT OF OUTPUT CIRCUIT
(1)
Alarm input (OUT1/OUT2): NPN Open collector pulse output
(2)
Alarm output (OUT3/ OUT4) : PhotoMOS relay output
P13
8.
SETTING UP THE DIP SWITCH
Setting up the DIP Switch
black shows the
DIP SWITCH
Push the 4 tabs at the side of case and pull the PCB backwords
Push the four hooks
Dip switch setting can switch mode from input respond frequency, NPN open collector pulse input and electric pulse input
B.IN A.IN
ON ON
OFF OFF
setting
max. link ejecting frequency 0.01Hz-50Hz (LOW) max. link ejecting frequency 0.01Hz-1kHz (MID) max. link ejecting frequency 0.01Hz-10kHz (HI) max. link ejecting frequency 0.01Hz-120kHz (OP.) NPN Open Collector Pulse Input Voltage Pulse Input
B. IN A. IN
1 2 3 4 5 6
ON OFF OFF ON OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
Fig. 20
Table 1
(1) Dip switch can be found from the slit on the right side's corner of the main body. (Ref. Fig. 20)
If it is not convenient to set, pull out the PCB from the case and do the setting.
(2) Following three kinds of input type has to be used with the factory preset mode;
Sinusoidal input(V3),sine curve input(N) and line receiver input(L1, L2).
(3) For 90°phase contrast input (RE)type,
make sure to keep the factory preset mode (HI) for both A/B inout for respond frequency.
(4) Dip switch setting must be done by the combinations shown on the above chart.
The usage of the combination which is not indicated above might cause some error.
P14
9.
SETTING MENU
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
T
RS
T
T
Mode
Mode
Mode
RS
ENT
ENT
Display
Mesurement
ENT
Power OFF
RS
ENT
Reset
Latch Signal Input
LED
Test
Output
Test Mode
OFF
Power
P15
Loading...