DT-326B LED Stroboscope
Operation Manual
Use in flammable environments is prohibited. Use in this manner may
result in fire or explosive.
Don’t look directly into the LED light Source. This may result in eye injury.
Don’t use or store in the following environments. Direct sunshine condensation, dust or caustic.
Do not alter, or modify of improperly. Such action may cause damage
and void warranty.
Operate with 0-35°C (32-95°F), 35-85% RH. Use outside of this range
may alter operation of the unit.
Case may become excessively hot when used continuously for more
than 2 hours. Mount unit on a tripod or other fixed device.
The DT-326B is a portable, light-weight stroboscope utilizing super bright CREE High Powered LED lamps. The DT-326B’s LED
array provides a bright, stable strobe light over a wide measurement range with a lifetime far exceeding xenon lit stroboscopes.
Containing a rechargeable lithium battery, a single charge can
last up to a full 12 hours of operation. The DT-326B is designed for
speed and frequency measurements in motion and vibration analysis. It is ideal for predictive and preventive maintenance applications such as: motors, shafts, roto-gravure printing, extruders,
blow molding, wire lettering and striping, engraving, pulse jets,
water jets, fans, cams, gear teeth, belt inspections, fuel injectors,
vibration analysis, audio speaker analysis, spindle spinning, cutting blade timing and sharpness, plus many more in the printing,
packaging, textile, automotive, cable, mining, steel, chemical, optical, medical and shipbuilding industries.
SPECIFICATIONS
Flash Rate Range: 60 to 120,000 FPM ; 1-2000 Hz
Accuracy: 0.01%±1 digit of F.S. @ 77° F (25°C)
Lux Rating (Approx.): 6000 FPM & 2.5°: Distance 8˝ (20 cm)
5800 lx with 4˝ (100 mm) irradiation dia., Distance 20˝ (50
cm) 1050 lx with 6˝ (152 mm) irradiation dia. 1500 FPM & 2.5°:
Distance 8˝ (20 cm) 6400 lx with 4˝ (100 mm) irradiation dia.,
Distance 20˝ (50 cm) 1125 lx with 6˝ (152 mm) irradiation dia.
Lamp Lifetime: Approximately 3~5 years depending on usage.
Display: Backlit LCD
Resolution: 60 ~12,000 FPM = 0.1 FPM; 12,001~120,000 FPM
= 1 FPM; 1~200 HZ = 0.01 Hz; 201~2000 = 0.1 Hz
Flash Duration: 0.1°- 2.5°
Phase Shift: 0-359°
Power Requirement: 100-240 VAC 50/60Hz
Battery: Lithium DC 12.6V 730 mAh
Battery Life: Approx. 12 hours depending on settings
Input Signal: 12 V Pulse Input: Mini-USB
Input Signal Range: 60-120,000 FPM (1-2000 Hz)
Input pulse width: over 50 µs
Input Signal Flash Delay: 0-999 ms; 0-359°
Temperature Limits: 32-95°F (0-35°C)
Humidity Limits: 35 to 85% RH
Enclosure: ABS
Product Weight: 0.84 lb (380 g)
Package Weight: 3.50 lb (1.6 kg)
Dimensions: 8.2 x 2.8 x 2.4” (208 x 70 x 60 mm)
Approvals: CE
Warranty: 1 year
Included Accessories: AC power adapter, Carrying Case
Operation Panel
1. POWER: Power on and off.
2. MODE: Select mode of operation: Internal/External/
Parameter Settings
3. SET: Scroll through parameter settings, Store setting values.
4. x2: Multiplies the flash rate/frequency by a factor of 2.
5. 1/2: Divides the flash rate/frequency by a factor of 2.
6. RATIO: Adjusts flash duration (flash pulse width) in Internal/
External modes.
7. “+”: Advance image forward 3 degrees at a time in internal
mode. In parameter setting mode, adjusts setting values.
8. “-”: Retard image backwards 3 degrees at a time in internal
mode. In parameter setting mode, adjusts setting values.
9. Dial: Set flash rate or frequency. CW: Increase flash rate/fre-
quency. CCW: Decrease flash rate/frequency. (Turn dial quickly
to drastically change value; Turn dial slowly to change value
by 1 digit.) In parameter setting mode, CW or CCW rotation
changes the setting value.
10: FPM/Hz: Select between FPM or Hz units of measure
2
1
3
4
5
6
7
8
9
10
LCD Display
Battery
Indicator
Display
Parameter
Icons
Sub
Data Display
Main Data Display
•Flash rate value will be displayed in internal flashing or External trigger mode.
Units
Main
Data
FUNCTION INSTRUCTIONS
Mode Selection - To switch between INTERNAL, EXTERNAL and
PARAMETER mode, press and release the MODE key. For details
about Parameter setting mode, please refer to Parameter setting
mode section.
•Display will indicate “P” or “LCD” (in ON/OFF setting of LCD
backlight) in *Parameter setting mode.
*For details about Parameter setting mode, please refer to Parameter setting mode.
Sub Data Display
Internal Mode
•Phase Shift will indicate degrees of phase shift in internal flashing mode. To change the degrees of phase shift, press + or keys. The display will reflect the cumulative angle of phase shift.
•The flash duration time will be displayed when the RATIO key
is pressed. The flash duration time can then be increased or
decreased with the dial from 0 to 2.5 (0~2.5°) degrees.
External Mode
• In external trigger mode, the display will show the settings of
delay time. For details about changing these settings, please
see external trigger mode section.
Battery Indication - Indicates remaining battery charge.
Note: The display will not indicate a battery charge when the unit
is being used with the AC Adapter.
Internal Flashing Mode
Changing Units of Measure in Internal Mode - To change the
measuring units from FPM to Hz, press and release the FPM/Hz
key. Units will alternate with each press and release.
Flash Rate (Frequency Setting) in Internal Mode You can set the flash rate by turning the dial in the center of the
unit. To increase the flash rate, turn the dial in the clockwise direction. To decrease the flash rate, turn the dial in the counter-clockwise direction. For small adjustments, turn the dial slowly. For
quick adjustments, rotate the dial quickly. The flash rate range
and resolution will be different according to the selected measuring range.
One function of a stroboscope is to provide a “stopped” image
of a rotating target when the flash rate of the stroboscope has
matched the rotational speed of the target object. The stroboscope will show a single image when the flash rate is set to a
lesser multiple of the true RPM (1/2,1/3,etc.) When the flash rate
is increased to a higher multiple (2,3,etc.), multiple images will
appear. To find the true RPM of the target object, reduce the flash
rate to a lower multiple until only one image appears.
Batter capacity is full
The Battery capacity is diminished Near zero
capacity
When battery is empty, the unit will power off
Remarks: It can be used for more than 12 hours continuously
when the frequency is 3000FPM or 50Hz.
2