Handheld Digital Tachometer
5.1 USB Connection Status
6. Continuous Data Import Screen
8. Memory Data Import Screen
14. Communication Commands
1. Introduction
・Microsoft Windows®10* (Japanese/English environment) 64bit
・Microsoft Windows®8* (Japanese/English environment) 32bit/64bit
・Microsoft Windows®7* (Japanese/English environment) 32bit/64bit
・Required Memory 4GB RAM
Thank you for purchasing the Handheld Digital Tachometer "DT-2100" (hereinafter referred to as the DT-2100).
This instruction manual summarizes the operation procedure of the DT-2100 specialized software.
2. Operation Environment
The operation environment for the DT-2100 specialized software is as follows:
Operation environment
*Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States
and/or other countries.
Communication method: RS-232C (Virtual COM port)
Communication protocol
3. Installation
Used for saving the CSV file
Initial folder to be specified at the time of
saving
(1) Application installation
Double click setup.bat in the installation media "setup" folder to execute installation.
When installation is completed, the following files and folders are created under "C:\DT-2100".
(2)File configuration
(3) USB driver installation
To change the COM port number, select
"Properties" in the right-click menu.
The COM port number displayed here becomes the port number
to be used in the application.
Select the COM port number, and click
[OK] to finish the COM port change.
When connecting a USB device to the PC where the DT-2100 has been installed, the USB driver is automatically installed.
Wait for several minutes until the installation is completed.
(4) COM port setting
Select "USB Serial Port" created under [Control Panel] - [Device Manager], and start to set the port.
If the driver is not recognized correctly, perform [Update Driver] according to the following procedure.
Select from among COM1 to COM15.
Detects the available ports automatically, and attaches "*" before the COM number.
Opens the selected COM port, and displays the main screen.
4. Starting Application
Double click "DT-2100.exe" in the installation folder to start application.
*Label and message descriptions depend on the language setting. (same as those for other screens)
*The initial language setting is English. From the next startup, the application starts with the language set when last closed.
5. Main Screen
Select the language from Japanese or English.
Displays the USB connection status.
(4) CONT_DATA_TRANSFER button
Displays the Continuous Data Mode screen.
(5) MEM_DATA_TRANSFER button
Displays the Memory Mode screen.
Displays the SET_USER screen.
Displays the SET_SYSTEM screen.
Displays the SEL_USER screen.
(4) CONT_DATA_TRANSFER button
(5) MEM_DATA_TRANSFER button
5.1 USB Connection Status
Check the connection status with the DT-2100 in the status display screen.
6. Continuous Data Import Screen
Upper/lower judgment marks: Compared to the values specified in the user setting,
indicates the upper limit mark when the upper limit value is less than the measurement
value, and the lower limit mark when the lower limit value is more than the
measurement value.
Measurement unit: Indicates the unit specified in the user setting, and indicates
"OVER" when the measured value exceeds the measurement range.
Measurement value: Indicates the measurement value (6 digits + decimal point).
When the measurement value exceeds 999999, indicates "------" (hyphens).
For the imported measurement data, indicates the maximum value/minimum
value/average value/standard deviation, the number of measurement data, and the
measurement start/end time. Updates during measurement.
For the average value, when the integer part of the calculated result has x digits, the
number of digits after decimal point becomes 6-x.
(3) Import control setting
Import start trigger: After the measurement value exceeding the Start Trigger setting
value is detected, starts importing.
Import time limit: Finishes importing when the Limit (sec.) setting value has elapsed.
Upper/lower judgment values: Indicates the upper/lower judgment values specified in
the user setting.
Indicates the measurement interval specified in the system setting.
Indicates the save destination folder selection screen.
Saves the measurement data being displayed and statistics data (Max./Min./Ave./SD)
to the file in the CSV format.
Indicates the file selection screen.
Creates a new block, and reads the selected measurement data into it.
(7) Start button /
Stop button
Select the "CONT_DATA_TRANSFER button" in the menu to display the continuous data import screen.
*The measurement data and block tab are synchronized with the graph screen.
(7) Start button
/Stop button
Press the Start button to start importing the data. The Start button then becomes the
Stop button.
Press the Stop button to finish importing the data. The Stop button then becomes the
Start button.
During data import, buttons other than the Stop and Graph buttons, as well as the
selection columns are disabled.
Click this button to display the confirmation screen. Click OK to delete the block that
has been selected.
When there are blocks No.1 to 4 and you delete block No.3, block No.4 is changed to
No.3.
Click this button to keep only the data that has been selected.
Click this button to display the Graph screen.
Indicates the measurement data for every measurement. Up to 1000 block.
Creates a new block for every measurement by pressing the Start button.
Indicates the measurement value. Up to 65535 data points can be imported.
Importing ends automatically when the maximum number of data points is attained.
6.1 Measurement Display
Indicates the data importing status during measurement.
(1) Measurement value
●Indicates the measurement value (6 digits + decimal point).
●When the measurement value exceeds 999999, indicates "------" (hyphens).
(2) Upper/lower limit judgment marks
●Indicates the upper limit mark when COMPARATOR UPPER_LIMIT in the user settingis less than the measurement data.
●Indicates the lower limit mark when COMPARATOR LOWER_LIMIT in the user setting is more than the measurement data.