ShenZhen JPDFR302 User Manual

Page 1
JPD-FR302
User Manual
Version: 1.0 Prepared in August 2015
Infrared Thermometer
Page 2
User Instructions
Thank you for choosing the infrared thermometer produced by
Jumper Medical Equipment Co., Ltd. For proper use of the product, please read this manual before using the product, and follow this manual when operating the product .
Before using the product, please read and follow Safety
Precautions.
Please keep this manual with the product, so that you can refer
to this manual in case of need.
Page 3
Contents
Standard Packing List .................................................................... 1
Safety Precautions ......................................................................... 2
Warning ......................................................................................... 4
Symbol Conventions ...................................................................... 5
Product Introduction ....................................................................... 6
Functions and Features ................................................................. 7
Schematic Diagram of Appearance ................................................ 9
Measurement Method .................................................................... 9
Connecting the Thermometer to an APP Application of a Mobile
Phone .......................................................................................... 12
Display and Operation Instructions ............................................... 13
Battery Replacing Method ............................................................ 17
Cleaning and Disinfection ............................................................ 18
Maintenance ................................................................................ 20
Troubleshooting ........................................................................... 21
Technical Specifications ............................................................... 24
Safety Class ................................................................................ 25
Transportation and Storage Conditions ......................................... 25
Appendix IManufacturer’s Declaration of the EUT ..................... 26
Page 4
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1this device may not cause harmful interference. 2this device must accept any interference received, including
interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the recerver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Page 5
Warning:Changes or modiflcations to this unit not expressly approved by the party responsible for compliance could void the user’s authorty to operate the equipment.
ISED Statement
- English: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must a ccept any interference, including interference that may cause undes ired operation of the device.
- French: Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
The device has been evaluated to meet general RF exposure requi rement. The device can be used in portable exposure condition without restriction
Page 6
No.
Name
Remarks
1
Infrared thermometer x 1
2
Earcap box x 1
3
Dry battery x 2
Battery specification AAAx 2
4
Pouch x 1
5
User manual x 1
Unpacking Check
Please open the package carefully before use, check that all accessories are contained. Check whether any component is damaged due to improper transportation, and perform installation and operation following this user manual. If any damage or operation problem exists, please contact the dealer or directly contact Jumper Medical Equipment Co., Ltd. When contacting us, please provide the following information: device model, serial number, purchase date, and your contact information and address.
Standard Packing List
1
Page 7
Safety Precautions
Before using the thermometer, please carefully read the following precautions:
Caution
This product cannot be used to replace a monitoring instrument
that continuously monitors the body temperature.
The temperature probe is a sensitive component of the infrared
thermometer, and keep it carefully.
Do not discard the exhausted battery at will; take it to a specified
environmental protection place for processing, so as to avoid
environmental pollution.
Remove the battery if the product has not been used for more
than two months.
Never put the product into water or under the sun; otherwise,
the product may be damaged or suffer accelerated aging.
Do not acutely vibrate the product or collide it with other things;
otherwise, it may be damaged.
The normal body temperature varies from person to person. You
are advised to record daily measurement values and use them
as reference values to determine whether you have a fever.
Your body temperature rises when you are taking exercise or
have emotional outbursts. In this case, you are not advised to measure your body temperature. After exercise, take a 20-minutes rest before making measurement.
2
Page 8
After using the product, clean it and keep it in a dust-free, dry,
and ventilated place. When using the product, note the safety precautions below: The product is not waterproof, and do not put it into water or
other liquid. For the cleaning and disinfection method, see
Cleaning and Disinfection.
Do not directly contact the top of the temperature probe, where
there is a precise temperature sensor at the top. Keep the temperature probe clean, and clear away dirt or
cerumen, which may affect the measurement result. When there is dirt in the auditory meatus, use a cotton ball to
clean it before making measurement. The measurement environmental temperature should not be too
low or too high. After the instrument enters the measurement
environment from the storage environment, make measurement
30 minutes later. Do not make measurement at a temperature higher than 40C
(104F) or lower than 10C (50.0F) because the temperature in
this case is beyond the normal working temperature of the
thermometer. Do not use the thermometer for unexpected purposes, and
follow the safety precautions when making measurement for a
child.
3
Page 9
Warning
Warning
During measurement, do not forcibly insert the temperature
probe into the auditory meatus, which may hurt the auditory
meatus. The thermometer is not a diagnostic instrument, and the
measurement result is only used as reference for a doctor. It is risky to perform auto-diagnosis and treatment according to
the measurement result; follow the doctor's diagnosis. Do not refit the product without permission of the manufacturer,
which may damage the product or cause safety problems. The thermometer can be used cooperatively with a dedicated
earcap. When no earcap is used, you are advised to use the
thermometer for only one person, so as to avoid cross infection.
Do not charge or put the common alkaline dry battery into the
fire, so as to avoid a risk of explosion.
Do not disassemble or repair the thermometer if you are not
professional, so as to avoid causing irreparable damage.
During measurement, do not use a mobile phone or another
device with strong electromagnetic field interference.
Do not use the thermometer in an environment where there is a
gas mixture of inflammable anesthetizing gas and air, or a gas
mixture of oxygen and nitrous oxide.
4
Page 10
Do not use the thermometer to make measurement for any part
Symbol
Description
BF-type application part
Caution! Please see this manual.
Indicates general prohibitions, where specific content
is described following the symbol.
Manufacturer information including the name and
address of the manufacturer
Date of manufacture, where specific year and month
are shown before or below the symbol
When end users abandon this product, they must send the product to the collection place for recycling.
IPX0
Waterproofing grade, indicating that this product is not
water-proof
Low battery voltage
Warning
Indicates that an individual may be hurt or the
instrument may be damaged in case of wrong usage.
of the body except the ear; the measurement result may be
incorrect.
Keep out of reach of children.
Symbol Conventions
5
Page 11
Caution
Indicates that the measurement result may be incorrect or the instrument may be damaged in case of wrong
usage.
Product Introduction
(1) Overview The JPD-FR302 infrared thermometer (referred to as thermometer in the following) is a measurement instrument that uses the infrared receiving principle to measure the temperature in the tympanic membrane of the earhole. You only need to insert the temperature probe into the earhole and place it at the correct position, and press the measurement key to quickly and correctly measure the ear
temperature.
(2) Product Structure This product mainly consists of a casing, a liquid crystal display, a press key, a buzzer, an infrared sensor, and a microprocessor.
(3) Measurement Principle The infrared thermometer uses the infrared temperature sensor to receive infrared energy emitted by heat generated in the tympanic membrane of the earhole. The energy penetrates through the lens and becomes concentrated, and is further converted into a temperature value by using the thermopile and measurement circuit.
6
Page 12
(4) Expected Usage This product intends to be used by a medical department or a family to measure the body temperature.
(5) Scope of Application The temperature of a measured object is displayed by measuring
thermal radiation of the thermal radiation of the earhole.
(6) Contraindications Do not use this instrument for an individual having diseases such as
otitis media and ear fester.
Functions and Features
1. High Safety
Passive infrared receiving technology without radiation Disposable earcaps that avoid cross infection
2. Easy Operations
7
Page 13
Conforming to ergonomic design One-key measurement and automatic temperature
measurement No interference to daily life, where measurement may be made
when a child is asleep
3. Fast Measurement One-second measurement and no waiting
4. High Accuracy Advanced infrared temperature sensing component with high
sensitivity Temperature correction program that ensures precise
calculation, where the measurement result truly reflects the
body temperature
5. Practical Functions Function of memorizing 20 groups of measurement data that
helps effectively track a change status of the temperature
Function of measuring the temperature of the ear Function of reminding a fever by using audio Function of Celsius degree/Fahrenheit degree conversion Automatic power-off function, consuming less power Bluetooth tethering function and APP program application
6. Wide Target Users Applicable to individuals older than three months
8
Page 14
Schematic Diagram of Appearance
Measurement Method
1. Precautions before Use
1) This thermometer is applicable to indoor environments. There
should be no strong cross-ventilation between the instrument
and a measured object during measurement (for example, a fan,
an air-conditioner, and a heater blow against each other).
2) This thermometer is sensitive to the environment temperature;
do not hold the thermometer for a long time.
3) Keep the temperature probe clean and unblocked before using
the thermometer.
4) Before measuring the temperature of the ear, keep the auditory
meatus clean; otherwise, the measurement result may be
incorrect.
9
Page 15
5) Do not have emotional outbursts or take acute exercise before
measurement.
6) Make measurement 30 minutes later after taking the
thermometer into the measurement environment, if there is a
temperature difference between the storage environment and
the measurement environment.
7) The measured individual is advised to take a more than 10
minutes rest before measurement, if the individual enters the
measurement environment from an environment and there is a
temperature difference between the two.
2. How to Measure the Temperature of the Ear
1) Cover the temperature probe with an earcap
Put the earcap into the earcap box, open the top cover of the earcap box, pull out one earcap, place it at the hole on the top, and keep it flat, and press downwards the temperature probe of the thermometer in the transparent film direction in the middle of the earcap until the earcap fully covers the temperature probe. Take out the
temperature probe and close the earcap box cover.
2) Insert the temperature probe into the auditory meatus and place
it at the correct position (shown in the following figure) When making measurement for an adult, lift the ear slightly upwards; when making measurement for a child, lift the ear slightly backwards
10
Page 16
to make the auditory meatus straight and the temperature probe aim at the tympanic membrane direction.
3) When measuring the temperature of the ear, press and release
the measurement key. The buzzer beeps once, and the display
screen displays the measurement value about 1s later.
3. End of Measurement
11
Page 17
1) After the measurement is completed, in the power-off state, long
press the measurement key for more than 4s but less than 6s to
enter the memory query mode, in which you can view previous
measurement records. For detailed operations, see Query of 20
Groups of Memory Data in the following table.
2) After the measurement is completed, use a dry, soft cloth to
wipe the thermometer, and keep the thermometer in a dry and
ventilated place.
3) The thermometer is automatically powered off if no key is
operated for 10s.
Connecting the Thermometer to an APP Application of a Mobile Phone
The thermometer has a built-in Bluetooth module and can be connected to a smartphone by using the Bluetooth 4.0 wireless technology. View the measurement data in real time by using mobile phone software "MyThermo". The software automatically saves the measurement data and draws a temperature curve graph, which
helps view the temperature change status in real time.
For a method for connecting the thermometer to the mobile phone, see Operation Instruction.
12
Page 18
Display and Operation Instructions
LCD Display
Operation Method and Display Instructions
Sound and Backlight
In the power-off state, press the measurement key for less than 4s. Then, the thermometer displays the measurement value and starts up.
One long buzzing sound and 3s green backlight
After the backlight dies out, the thermometer enters the ready-for-measurement state, and a symbol of a corresponding mode appears. In this case, the measurement prompt symbol blinks.
1. When 32.0C < T <
37.6C, one long buzzing sound and 3s bright green backlight
2. When 37.6C  T
42.2C, seven rapid short buzzing sounds and 3s bright green backlight
When the temperature of the surrounding object or environment during measurement is within the following range: 0C T 32.0C or 42.2C T 100.0C, a symbol appears,
13
Page 19
and it is automatically identified as the temperature of the object.
When the measured temperature is higher than 100C (212F)
Three short buzzing sounds and 3s green backlight
When the measured temperature is lower than 0C (32F)
Three short beeps and 3s green backlight
Query of 20 Groups of Memory Data
LCD Display
Operation Method and Display Instructions
Sound and Backlight
In the power-off state, press the measurement key for more than 4s but less than 6s. Then, the LCD displays "- - - ", and the M symbol blinks.
No sound is emitted.
Press the measurement key again. Then, the LCD displays the first memory value, and the M symbol blinks. Each time you press the measurement key once, the LCD displays a memory number for 1s and then displays the memory measurement value, where
No sound is emitted.
14
Page 20
there are 20 groups of memory data in total.
If there is no measurement data, the LCD displays only "-
- - " and the M symbol, and the M symbol blinks.
No sound is emitted.
C/F Conversion
LCD Display
Operation Steps
Sound and Backlight
In the power-off state, press the measurement key for more than 6s but less than 8s to enter the temperature unit conversion mode. Within 5s after releasing the measurement key, press the measurement key again, and then, the temperature unit is converted once, until the measurement key is released for more than 5s and the thermometer is automatically powered off.
No sound is emitted.
Display of Incorrect Information
When the environment temperature is higher than
40.0C (104F) or lower than
10.0C (50.0F), "Er1" is displayed.
Three short buzzing sounds and 3s green backlight
15
Page 21
When there is a read/write error in the EEPROM data or correction is not completed, "ErC" is displayed. In this case, contact the supplier.
Three short buzzing sounds and 3s green backlight
When the voltage of the battery is lower than
2.51V±0.15V, a low voltage symbol (not blinking) is displayed after the thermometer is powered on. In this case, replace the battery.
No sound is emitted.
16
Page 22
Battery Replacing Method
1) When replacing the battery, press and hold the upward sign on
the battery cover, take off the battery cover, put two AAA
batteries into the battery holder according to electrode signs,
and close the battery cover.
2) After the thermometer has been used for a period of time, if the
display screen displays the low voltage symbol after the
thermometer is powered on, replace the batteries with new ones
before normally using the thermometer.
When installing the battery, install it according to the electrode signs; otherwise, the instrument may be damaged.
Use batteries of the same type or specifications; do not randomly discard the exhausted batteries, but process the exhausted batteries according to local environmental requirements.
Batteries are built in at the time of factory delivery, and you only need to take out the insulation strip.
17
Page 23
Cleaning and Disinfection
Device Cleaning:
Recommended detergent: * Medical detergent * Household neutral detergent Cleaning steps:
1) Take out the battery before cleaning.
2) If the instrument body is dirty, use a soft and clean cloth to soak
neutral detergent or water, wring the cloth and then wipe the instrument body, and immediately use tissue or dry cloth to wipe the instrument body.
3) Use a clean and soft cloth to wipe the temperature probe of the
thermometer, and use a cotton ball to clean the lens.
4) After the cleaning, place the thermometer in a dust-free, dry,
and ventilated place.
During cleaning, keep the lens of the temperature probe away
from water; otherwise, the temperature probe may be damaged.
The lens of the temperature probe may be scratched if tissue is
used to wipe the lens, and the measurement result may be incorrect.
Do not use corrosive detergent or acidic or alkaline detergent.
During cleaning, do not use a stiff object to contact the lens of the temperature probe, do not put any part of the thermometer into liquid, and prevent liquid from flowing into the instrument.
18
Page 24
You are advised to clean the thermometer weekly, finish cleaning within 3 minutes each time, and clean the thermometer not more than three times each time.
Disinfection:
Recommended sanitizer: * Isopropanol solution of 70% concentration * Medicinal alcohol of 75% concentration * Sodium hypochlorite solution of 3% concentration Disinfection steps:
1) Use a clean soft cloth to soak a small amount of disinfectant to
wipe the instrument body, and immediately dry it.
2) Use a clean cloth to soak a small amount of medicinal alcohol of
75% concentration to wipe and disinfect the periphery of the temperature probe.
Do not disinfect the instrument by means of high-temperature steam or ultraviolet irradiation, which may damage the instrument or accelerate aging of the instrument.
You are advised to disinfect the thermometer before and after using it each time, finish disinfection with 1 minute each time, and disinfect the thermometer not more than two times each time.
Perform cleaning and disinfection in the following environment: temperature: +10C to +40C(50F to 104F); humidity 15% to 85% RH without condensation; barometric pressure: 86kPa to 106kPa.
19
Page 25
Maintenance
1) Each time finishing using the instrument, clean the instrument
body and the temperature probe and perform operations
following Cleaning and Disinfection.
2) Keep the thermometer in a dry, ventilated, dust-free, and
pollution-free place, prevent the thermometer from direct solar
radiation, and store and transport the thermometer according to
corresponding environment requirements.
3) Regularly check the thermometer to determine whether there is
a potential safety hazard, so as to ensure safe use.
4) If the thermometer has not been used for a long time (more than
two months), take out the battery for storage.
20
Page 26
Troubleshooting
Fault
Symptom
Possible Cause
Solution
Failing to start
up
The battery level is
extremely low.
Use new batteries of the same type or
specifications.
The batteries are installed according to wrong positive and
negative electrodes.
Check whether the batteries are installed in the battery holder according to the
electrode signs.
The instrument is
damaged.
If the instrument is within the warranty period, contact the after-service department of the manufacturer for free
repairing.
Only the battery symbol is displayed after the instrument is
powered on.
The battery level is low.
Use new batteries of the same type or
specifications.
Only "Er1" is displayed
The environment temperature is higher
Make measurement at an environment
21
Page 27
Fault
Symptom
Possible Cause
Solution
after the instrument is
powered on
than 40C or lower than
10C.
temperature of 10C
to 40C.
"ErC" is displayed after the instrument is
powered on
There is a read/write error in internal storage data or temperature correction is not
completed.
Contact the manufacturer for
processing.
The measurement result is lower than a normal
value
The lens of the temperature probe is
dirty.
Use a cotton ball to clean the lens of the temperature probe, to ensure that the lens is
not blocked.
The measurement method is incorrect that the temperature probe is too far away from the
measured position.
Make measurement according to the correct method, and shorten the measurement
distance.
After entering the measurement environment from a colder environment, the thermometer is not placed for more than 30 minutes.
Place the thermometer in the measurement environment for more
than 30 minutes.
22
Page 28
Fault
Symptom
Possible Cause
Solution
The measurement result is higher than a
normal value
The temperature probe is damaged. There is direct incidence
of strong light.
Contact the manufacturer for repairing. Do not make measurement under
strong light.
23
Page 29
Technical Specifications
Product Name
Infrared thermometer
Model
JPD-FR302
Battery Working Mode
Internal power supply Working Voltage
DC 3V
Battery Specifications
AAA×2 Battery Life
Alkaline dry battery, about 20000 times
Running Mode
Short-time continuous running
Input Power
Less than 60mW
Display Mode
Segment LCD
Measurement Time
About 1 second
Emissivity
0.95
Temperature Unit
C/F can be set.
Measurement Range
Temperature: 32.0C to 42.2C (89.6F to
107.9F)
Precision
±0.2C/±0.4F
Display Resolution
0.1C/0.1F
Memory Storage
Twenty groups of measurement data
Low-voltage Prompt
Lower than 2.51V ± 0.15V, where the low voltage symbol is displayed when the instrument is powered on
Automatic Power-off Time
10s±1s Dimension (mm)
150 × 40 × 38
Weight (g)
Instrument body: 85.0 g (excluding batteries); earcap box: 37.5 g
Quantity of Earcaps in Earcap Box for Standard Configuration
30 pieces
Work Environment Temperature: +10C to +40C (50F to 104F)
Humidity: 15% to 85% RH, without condensation
24
Page 30
Barometric pressure: 86kPa to 106kPa
Accuracy of Clinical Diagnosis Test
The maximum permissible error of the accuracy of clinical diagnosis test is specified by using the formula below:
0.3C/0.6F (for 95%) where, T1 and T2 are two temperature reading values of two times of measurement of the tested thermometer, and Tref is a fixed reference temperature.
T2-Tref
+
2
Safety Class
Anti-electric-shock type: internal power supply device Anti-electric-shock level: BF-type application part; symbol:
Fluid-proof level: IPX0, non-water-proof
Transportation and Storage Conditions
1) Transportation
Use general transportation tools, and prevent the instrument from strong shocks, vibration, and water.
2) Storage
Store the packed infrared thermometer in a ventilated indoor place where an environment temperature is -10C to + 50C, relative humidity is less than 93% without condensation, the barometric pressure is 50kPa to 106kPa, and no corrosive gas exists.
25
Page 31
26
Appendix IManufacturer’s Declaration of the EUT
The Infrared Thermometer JPD-FR302 is intended for use in the electromagnetic environment specifiled below. The customer or the user of the Infrared Thermometer JPD-FR302 should assure that it is used in such an environment.
Emissions test
Compliance
Electromagnetic environment ­guidance
RF emissions CISPR 11
Group1
The Infrared Thermometer JPD-FR302 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emissions CISPR 11
Class B
The Infrared Thermometer JPD-FR302 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
Harmonic emissions IEC 61000-3-2
N/A
Voltage fluctuations / flicker emissions IEC 61000-3-3
N/A
Guidance and manufacturer’s declaration – Electromagnetic emissions – for all equipment and systems
Page 32
27
Guidance and manufacturer’s declaration – Electromagnetic
The Infrared Thermometer JPD-FR302 is intended for use in the electromagnetic environment specifiled below. The customer or the user of the Infrared Thermometer JPD-FR302 should assure that it is used in such an environment.
Immunity
test
IEC 60601 Test Leve
Complian
ce level
Electromagnet
ic environment
-guidance
Electrostatic discharge (ESD) IEC 61000-4-2
6 kV contact
8 kV air
6 kV
contact
8 kV air
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %.
Electrostatic transient / burst IEC 61000-4-4
2 kV for power supply lines
1 kV for input / output lines
N/A
Surge IEC 61000-4-5
1 kV differentia mode
2 kV common mode
N/A
Voltage
<5 % UT
N/A
immunity – for all equipment and systems
Page 33
28
dips, short interruption s and voltage variations on power supply input lines IEC 61000-4-11
(>95% dip in UT) for 0.5 cycle
40 % UT (60 % dip in UT) for 5 cycles
70 % UT (30 % dip in UT) for 25 cycles
<5 % UT (>95 % dip in UT) for 5 sec
Power frequency (50/60Hz) magnetic field IEC 61000-4-8
3 A/m
Power frequency magnetic ields should be at levels characteristic of a typical location in a typical commercial or hospital environment
Guidance and manufacturer’s declaration – Electromagnetic immunity – for equipment and systems that are not life-supporting
Page 34
29
The Infrared Thermometer JPD-FR302 is intended for use in the electromagnetic environment specifiled below. The customer or the user of the Infrared Thermometer JPD-FR302 should assure that it is used in such an environment.
Immunity test
IEC 60601 Test Level
Compliance
level
Electromagnetic environment­guidance
Conducted RF
IEC 61000-4-3
Radiated RF IEC 61000-4-3
3 Vrms 150 kHz to 80 MHz
3 V/m 80MHz To 2,5 GHz
N/A
3 V/m
Portable and mobile RF communications equipment should be used no closer 10 any part of Ihe JPD-FR302 including cablesthan the recommended separation distance calculaled from the equation applicable to the frequency of the transmitter.
Recommended separation distance
d =
p][
1
5.3
E
80 MHz to 800 MHz
d =
p][
17E
800 MHz to 2.5 GHz
Page 35
30
where P is Ihe maximum oulput power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters , as determined by an electromagnetic site survey,a should be less than the compliance level in each frequency range.b lnterference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHzthe higher frequency range applies.
Page 36
31
NOTE 2 These guidelines may not apply in all siluations. Eleclromagnetic propagation is affected by absorption and reflection from slructures, objecls and people.
Field strengths from fixed transmitterssuch as base stations for radio (cellular/cordless) telephones and land mobile radios,
amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the JPD-FR302 is used exceeds the applicable RF compliance level abovethe
JPD-FR302 should be observed to verify normal operation. If abnormal performance is observedadditional measures may
be necessarysuch as re-orienting or relocating JPD-FR302. Over the frequency range 150 kHz to 80 MHzfield slrengths
should be less than 3V/m.
The Infrared Thermometer JPD-FR302 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Infrared Thermometer JPD-FR302 can help prevent electromagnetic interference by maintaining a minimum
Recommended separation distances between portable and mobile
RF communications equipment and the ME EQUIPMENT or ME
SYSTEM - for ME EQUIPMENT and ME SYSTEMS that are not
LIFE-SUPPORTING
Page 37
32
distance between portable and mobile RF communications equipment (transmitters) and The Infrared Thermometer JPD-FR302 as recommended below according to the maximum output power of the communications equipment.
Rated
maximum
output
power of
transmitter
W
Separation distance according to frequency of
transmitter
m
80 MHz to 800 MHz
800 MHz to 2.5 GHz
d=
p][
1
5.3
E
d =
p][
17E
0.01 0.12 0.23
0.1 0.38 0.73
1 1.2 2.3
10 3.8 7.3
100 12 23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHzthe separation distance for the
higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Page 38
Wellkang Ltd
Suite B, 29Harley Street, LONDON, W1G9QR,U.K.
Shenzhen Jumper Medical Equipment Co., Ltd
5th Floor Building No.34,Baoyuan lndustrial Zone,Xixiang Street,Baoan District,Shenzhen,Guangdong 518102 .P.R. China Phone: +86-755-26696279 Fax:+86-755-26852025 Mail:info@jumper-medical.com
Loading...