4.1 Connecting the power and signal cables .................................................................................................................8
4.1.1 Little cover (removing) ................................................................................................................................8
4.1.3 Little cover (attaching)...............................................................................................................................10
4.2 Switching on the display .......................................................................................................................................10
4.3 Adjusting the image geometry ..............................................................................................................................10
4.4 Adjusting the brightness and contrast ...................................................................................................................10
5.3 Information on additional serial interface (Service Only).....................................................................................12
5.4 Analog and digital inputs (DVI-D, VGA).............................................................................................................12
5.5 Power supply connection ......................................................................................................................................13
5.6 Serial interface ......................................................................................................................................................13
6.3.5 Locking of OSD menu ...............................................................................................................................17
6.3.6 Keys function hints ....................................................................................................................................17
6.4 Description of the menus ......................................................................................................................................18
8. Technical data .................................................................................................................................................................22
8.2 Power supply......................................................................................................................................................... 22
8.4.1 Analog signal input ....................................................................................................................................23
8.4.2 Digital signal input.....................................................................................................................................23
8.4.3 Serial interface ...........................................................................................................................................23
8.5 Controls and connection elements ........................................................................................................................24
9.1 Front 、Platform and Side view ..........................................................................................................................28
10 Remarks and contact address .........................................................................................................................................29
..................................23
I
REV A
Federal Communications Commission(FCC) Statement
You are cautioned that changes or modifications not expressly approved by the part
responsible for compliance could void the use’s authority to operate the equipment
FCC-Class B
This equipment has been tested and found to comply with the limits for a
Class B digital device,
Pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a communications.
However , these is no guarantee that interference will not occur in particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
1. Application
This high-resolution color display is specifically designed to meet the rigorous
performance standards needed for diagnostic, interventional radiology, and other medical
applications. To guarantee image integrity, features include accurate signal conversion and
a wide range of interfacing options.
Compact design -Low weight and small size with improved performance make the
monochrome\color flat panel display C14S\G11S preferable to conventional CRT
monitors.
Embedded LUT-This monitor is factory calibrated to achieve DICOM part 3.14
compliance and Linear gray level reproduction at the factory set point. 5 different settings
are stored within the display.
Screen resolution- C14S\G11S is equipped with a panel with Super In Plane switching
technology. The optimal picture resolution is 1280 x 1024 pixels. Video signals with other
resolutions typical to medical engineering are optimally zoomed in or out to the screen
size.
1
REV A
2. Declarations
Safety precautions
With respect to electric shock,
Fire and mechanical hazards
only in accordance with
IEC、UL60950-1 and CAN/CSA
C22.2 No. 609501-1
Regular maintenance and calibration are recommended
Please note that liquid crystal displays such as the C14S\G11S do not have a
failure rate of zero and image parameters may change over time (e.g.
luminance or discoloration). Please ensure that all measures are taken to
prevent injuries or incorrect diagnoses. Regular maintenance and calibration
are recommended.
Correct and safe operation of the flat panel displays is dependent on proper
transport, storage, installation and assembly, as well as careful operation and
maintenance. The units must only be used for applications for which monitors
are normally used. The information in the Section "Technical data" must be
observed exactly.
For the sake of safety, the following precautions must be observed:
Explanation of the symbols
2
REV A
Attention: Consult the accompanying documents
ATTENTION:Risque de choc electrique, Ne pas ouvrir
European comformity
China Quality Certification
Alternation current (AC)
Protective earth
CAUTION:Risk of electric shock. Do not open.
Dispose of in accordance to your countries requirements
Conformance with FCC Rules and Regulations
UL approval mark
China Rohs symbol
Danger: There is a danger to life if the warning information is not
observed. Severe personal injury or damage to property may occur.
Do not open the unit yourself.
Certain components inside the units are at high-voltage, i.e. touching these
3
REV A
components presents a danger to life!
Only use a perfect power supply cable
A damaged power supply cable may result in a fire or electric shock. When
disconnecting the power supply cable, always do so by holding the plug.
Only use the same type of fuse
2A/250V
Do not insert any objects into the housing
Objects inserted into the housing may result in damage to the unit or personal
injury.
Do not place any objects on top of the units
Penetrating liquids may result in a fire or electric shock.
Connection
No contact to a patient must occur when handling the cables.
Caution
Incorrect installation may result in extensive damage to property.
Installation should be carried out by trained personnel
When installing your medical electrical system with our products in an
environment with patients, please observe the safety requirements of EN
60601-1 (IEC60601-1) for "Specifications for the safety of medical electrical
systems" in order to prevent injury to patients and users of your systems.
Take appropriate measures to particularly ensure that discharge currents
remain below the required limits: Appropriate measures:
- Disconnecting devices for signal input or output unit
- Use of a safety transformer
- Use of additional PE conductor
Only use the signal cables and interface cables specified by the manufacturer
for the installation.
Use power cables with a PE contact. Only insert into sockets with a PE
contact.
For certain applications, the video earth can be separately connected to the PE
via the additional PE connection in the plug panel (observe IEC 601-1-1).
Close the plug panel using the provided cover (meaning the display stand),
and secure using the screws.
Turn switch off and then remove power cord.
4
REV A
Mounting information: The stability of the display must be guaranteed
following mounting of the foot/holder. The immersion depth of the mounting
screws has to be 10 to 12 mm including a 3 mm VESA mounting plate. (See
also table "Mounting screws" on the following). All these requirements are
satisfied when using the original foot. All requirements must be observed
when using customer-specific mounting solutions.
Notice for users: The plug panel closed by the cover (display stand), must not
be opened by users.
Servicing information: If housing components have to be removed for
servicing, this must not be carried out in the presence of patients, the user, or
other persons not involved with servicing.
The following applies to installations in the USA and Canada: Molded power
supply plugs must comply with the requirements for "Hospital Grade
Attachments" UL 498.
Caution
Failure to observe the warnings may result in substantial damage to
property.
Provide sufficient heat dissipation
Slots are provided at the rear of the housing. The display must be placed or
secured on a hard, level surface at least 10 cm from the wall and 15 cm away
from other devices. Several displays can be butt-mounted horizontally and
vertically.
The following must be observed when mounting (VESA connection):
Mounting screws
Number 4
Thread M4
Strength 12
Immersion depth Min. 10 mm; Max. 12 mm
Torque Max. 3 Nm
The permissible ambient temperature range (5 °C ... 40 °C) must not be
violated. Do not subject device to unnecessary shocks. Take care when
transporting! Use the original packaging! The panel in particular should be
protected against shocks.
When touching the panel surface, the mechanical contact or an electrical
discharge may cause a brief disturbance in the picture quality.
5
REV A
Care of unit / cleaning agents
− The front panel is extremely sensitive to mechanical damage. Avoid all
scratches, knocks etc.!
− Remove water drops immediately; extended contact with water
dismonochromes the surface.
Clean the front panel when dirty using a micro fiber cloth and, if necessary, a
glass cleaning agent*. Only clean housing parts using a cleaning agent for
plastics*.
z Note:
Do not use cleaning agents containing solvent, e.g. petroleum spirit!
Environmental Requirements
Mercury
The Cold Cathode Fluorescent Lamp (CCFL) utilized as the light source
for LCD displays, The CCFL is a low-pressure discharge lamp. Construction of
the lamp uses a glass tube coated on the inside with an inorganic phosphor. The
sealed lamp’s envelope contains a mixture of mercury; Mercury damages the
nervous system and is toxic in high doses.
Lamp Disposal
Hg
Lamp(s) inside this product contains mercury and must be recycled or
disposed of according to state, local or federal law. For more information,
Contact the electronic industries alliance at www.Elae.org. For lamp specific
disposal information check www.lamprecycle.org.
6
REV A
3. Installation
Provide adequate ventilation
Ventilation slots are located on the rear of the housing.
Ambient temperature
The permissible ambient temperature range must not be violated.
Minimize reflections
The display should be positioned so that reflections of lights, windows,
furniture with shiny surfaces or light-monochrome walls do not appear on the
screen.
Minimize mirroring
In order to reduce mirroring on the unit, ceiling lighting or reflected light (no
dazzling) should be used. Mirroring can only be eliminated if the screen is
clean and free of grease. Clean the display using a suitable micro fiber cloth.
Change of environment
If the unit is brought into a warm environment from a cold one, water may
condense upon it. The unit should not be switched on until all the condensed
water has evaporated, including that inside the unit. This may take several
hours, depending on the conditions.
7
REV A
4. Start-up
Caution
In order to ensure safe operation of the equipment, close attention must be
paid to the information contained in this Instruction Manual as well as the
warnings in Section 2 "Safety precautions".
Caution Information for end customer
None of the settings must be changed on site by the user, otherwise the
guarantee is canceled. This also applies to settings made using the HL1916
keys. These are therefore locked for certain applications. If settings have to be
changed, please contact the responsible servicing department.
The display is designed for individual connection to a graphics card with a
power supply of 100 or 240 Volt (TN-S system with PE conductor). If the
display is to be used in a sequence of several displays, or if it is not exactly
known whether the graphics card standard can be output by the display, refer
to Section 5.1 "Connection of the flat panel display".
In order to start the unit properly, the following steps should be carried out in
the given sequence.
4.1 Connecting the power and signal cables
Caution
Use a power cable with PE conductor corresponding to the safety
requirements of the respective country of use. Note for North America:
Molded power supply plugs must comply with the requirements for hospitals
with respect to CSA Std. C22.2 No. 21 and UL 498.The power supply and
signal connections are located on the rear of the monochrome flat panel
display.
Note
Note that the cables are not positioned when you receive the display (power
cable and DVI-D cable). The following steps are only necessary if you need
to connect/disconnect the cables of the scope of supply.
4.1.1 Little cover (removing)
Remove the one screws with an M4 Slot screwdriver (one turn suffices). Open
the little cover and remove it
8
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.