■ MAIN PRODUCTS
SHENLAN
SH E N L A N Cor pora tio n
·SHENLAN electronic co., l td.
·Http://www.szshenlan.c om.cn
·E-mail:shenlan@szshenlan.com.cn
http://www.szshenlan.com.cn
NO:08073 8-P-SMD
●CONNECTIONS
1.Isolating the DC power supply when the non-isolation voltmeter and the
ampere m eter use together , prohibited to use a same DC power source or
two non-isolation DC power supply, otherwise possible to damage the meter.
2. Groups non-isolation voltmeters can use a same DC power supply,
eliminating the input signal and power source's potential difference as far
as possible to avoid display unstable, groups non-isolation ampere meters
can not use a same DC power supply.
3.Before turning on the meter’s power source, please first check the power
source’s polarity and the voltage to avoid damage to the meter.
4.Input signals cable should not too long, better to use twisted-pair shielded
cable; to a void interfere head stream, installing high frequency filtration
electric capacity .
·Voltage/Ampere/Resistance input
·K therm ocouple in put
·PT100 input
TC
+
-
COM
IN-
IN+
VCC
POWER
-
+
A
B B
VCC
B/COM
B
A
POWER
+
RTD
●CAUTIONS
*
·Built-i n C.T m eter
■COUNTER&TIMER&FREQUENCY
TACHO&LINE SPEED METERS
●MAIN FEATURES
●COUNTER/LENGTH METER COMPOSITIONS
DC 7-24V po wer supplyF
②VOLT----
Standard DC 5V power s upply
DC 7-12V p ower supply
H
●TIMER COMPOSITIONS
●TACHO/LINE SPEED/FREQUENCY METER
■ DIME NSIONS
·FUN1 :s et Max. co unti ng s peed
* ON:Short circuit insert,OFF:no-Short circuit insert
3 decimal point
SM4D
① ② ③ ④
① NAME---
4 Digi t serie s digit al m eter
SM4D
6 Digi t serie s digit al m eter
SM6D
NPN signal input
④ INPUT ---
P
PNP signal i nput
③ TYPE-- --C1C2
Wi th memo ry
C3 Up/down count
L1
Length function
L3 Up/down length
L2
Count fu nction
SM4D
① ② ③ ④
①NAME----
4 Digi t serie s digit al m eter
SM4D
6 Digi t serie s digit al m eter
SM6D
DC 7-24V po wer supply
F
②VOLT----
Standard DC 5V power s upply
DC 7-12V po wer supply
H
③ TYPE-- --
T1
T2
Wi th Mem ory functi on
Basic functi on
NPN signal input
④ INPUT ---
P
PNP signal i nput
SM4D
① ② ③ ⑤④
①NAME----
4 Digi t serie s digit al m eter
SM4D
6 Digi t serie s digit al m eterSM6D
DC 7-24V p ower supplyF
②VOLT----
Standard DC 5V power s upply
DC 7-12V p ower supply
H
③ TYPE-- --
RF
LS Line speed
Tacho&Freque ncy
HZ AC Power Fr equency
NPN signal input
④ INPUT ---
P
PNP signal i nput
⑤ OTHERS-
Standard Model
H High Frequenc y Model
●TECHNICAL PARAMETER
Memory function
E2PROM
Automatic data storage when power off
When measure overflow display:----or------
Reset input
Counter/Timer reset with external singals input
Max. ±0.02% ±0.05S(onl y for timer)
±0.1% rdg ±2digi t(only f or s peed m eter)
9999(4Digit),999999(6Digit)
4 digit di splay:14.2mm,6 digit:10m m
Test various impulse signal
With voltage input(PNP)and no- voltage input(NPN)
[Voltage input] Low:0~2V,high:5~30V
Input impedance:5KΩ
[No-voltage input] Short circuit impedance:≤1KΩ
Residual voltage≤2V
Open circuit impedan ce≥100KΩ
●COUNTER&LENGTEH METER SETTING
AC pow er frequenc y m eter input voltag e 60~3 00V,and
measure power fre quency:0~9999H z,The m eter based on
input s ignal adjus t the decim al poin t position automaticly.
·FUN2&FUN3 :set d ecimal point(only for length met er)
Press MD key for 2 seconds,enter into prescale value setting:the decimal
point start flickering,Touch MD key,move the decimal point position,Touch
SET key, change the setting value.first set prescale value,then set decimal
point position.when the setting finish,Press MD key for over 2 Sec. prescale
value will be save in E2PROM automaticly.and return to run.
●TIMER FUNCTIONS SETTING
·FUN1:set time m ode
·FUN2& FU N3: Se t tim e ran ge
FUN4
Funct ion
ON ON
OFF ON
ON
OFF
OFF
OFF
No decim al point
1 decimal point
2 decimal point
3 decimal point
●TACHO/LINE SPEED METER SETTING
·FUN3& FUN 4: set decim al p oint
Setting method is the same as the length meter’s settings method, please
refer to above.
* Contact signal input must select ON
FUN
FUN2
Measuring revolving speed(RPM) Measuring frequency(Hz)
Input frequenc y mi n.1Hz
(the display responds quickly)
FUN1
●AC POWER FREQUENCY METER FUNCTIONS
●CONNECTIONS
*
·Tacho/line speed meter input
COMINP
INN
VCC COM
IN VCC
·Power frequency meter input
COM
INP
INN
VCC
POWER
-
+
RST
●CONNECTION SAMPLES
Encoder si gnal input
Proximity/photoelectric sensor input
0V
+V
OUTB
INN
0V
+5V
INP
RST
+12V
+5 V
COM
OUTA
0V
+V
OUT
INN
0V
+5V
INP
RST
+12V
+5 V
COM
(NPN Mo de l)
●CAUTIONS
* The mete r’s actual length surpasses the outer covering
l ength, different model s has differen t length.
1. NPN and PNP signal input channel.
2. The length meter and the line speed meter can set prescale value and
decimal point position.
3. Counting speed can choose 30Hz/2000Hz .
4. Frequency&tacho meter max. input rate 10KHz (high type 100KHz).
5. Timer can choose various time range and time method .
6. EEPROM Automatic data storage when power off (option item) .
7. Power voltage DC 5V(Options:DC7~12V/DC7~24V)
FUN1 ON(Short circuit insert): m easure the time form power on or
control signal on.
FUN1 OFF(no-Short circuit insert): It doesn’t displays the time when power
on. m easure the time of control signal on, wi thout control signal keeps the time
value, and the next control signal on. the time reset and measure again.
·Before turning on the meter’s power source, please first inspect the power
source’s polarity and the voltage to avoid damage to the meter.
·Shield line much be used when the measuring input line is getting longer
or there lots of noises
·pleas e use separated line form high voltage line or power line in order
to avoid inductive noises.
·Prevent from violent vibration,shock and cover of heavy dust.
● Counter/ Length meter
●Tacho /Line speed meter
●Timer/ pulse width meter
●Volt/Ampere /Ohmmeter
● Watt /Watt fact or meter
●Inspect ing meter
●Proximity sensor
●Photoelectric sensor
●Encoder /Humiture sensor
●Solid state relay
●Parameter display meter
·Counter/Length meter /Timer input connections
FUN3
Meter
Input frequency min.0.1Hz
(the display responds slowly)
COM VC C
POWER
-
+
INPUT
COM
IN-
IN+ VCC
POWER
-
+
if the connection drawing doesn’t correspond to the drawing on the product,
please according to the drawing on the product.
Wi th m emor y
70mA max.(DC5V P ower supply)
DC5V±5%(Option:7~12VDC/7~30VDC)
min.100M Ω(at 500VDC)
AC2000V 50/60Hz for 1 Min ute
0~50ºC& 35%~85%RH
Power consumption
Power supply
Input mode
Display ran ge
DIsplay m ethod
Input l evel
Display accuracy
Timer Accuracy
Overflow indication
Insulation strength
Dielectric resistance
Ambient humidity
ON(Short circui t insert)FUN1
1 Max. s peed 30Hz
OFF(no-Short circuit insert)
Max. spe ed 2KHz
OFF
OFF
FUN3
Function
ON
FUN2
ON
OFF
ON
ON
OFF
no- deci mal p oint
1 decimal point
2 decimal point
·Set prescale value 0.001~9999(o nly for length meter)
·FU N1& F UN 2
ON(Short circui t insert)
OFF(no-Short circuit insert)
4 Digit tim er
ON ON
OFF ON
ON OFF
OFF
OFF
99.99s
99m59s
99h59m
9999h
6 Digit ti mer
99m59.99s
99h59m59s
9999h59m
99999.9h
FUN3FUN2
* ON:Short circuit insert,OFF:no-Short circuit insert
* ON:Short circuit insert,OFF:no-Short circuit insert
·Set prescale value 0.001~9999(only for line speed meter)
POWER
-
+
POWER
-
+
INP:voltage signal input (PNP);INN:non-voltage signal input (NPN);
RST:Reset signal input(The low level is effective). W hen counts up/down,
INP and INN are the phase difference inputs ,and the signal input o ptions:
PNP or NPN signal.
DC POEWER
Meter
DC POEWER
79
43
20
77
39.5
20
Cut-out Size
Unit:mm
14
2