Sheenway Asia ZW6306 User Manual

FCC / IC
En
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user ’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. Important note: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils exempts de licence d’Industrie Canada. Son utilisation est sujette aux deux conditions suivantes : 1) cet appareil ne doit pas occasionner de brouillage préjudiciable et 2) cet appareil doit accepter toutes les interférences reçues, notamment les interférences qui peuvent provoquer un fonctionnement non désiré. NOTE DE LA FCC : Le fabricant n’est pas responsable des interférences sur les fréquences radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de ce matériel. De telles modifications peuvent annuler le droit de l’utilisateur à utiliser cet appareil. REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et, s’il n’est pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage préjudiciable aux communications radio. Il n’existe toutefois aucune garantie que des interférences ne se produiront pas au sein d’une installation donnée. Si cet appareil occasionne un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit d’allumer et d’éteindre l’appareil pour déterminer sa responsabilité. Nous encourageons l’utilisateur à essayer de corriger ces interférences en appliquant une ou plusieurs des mesures suivantes : — Réorienter ou déplacer l’antenne de réception. — Augmenter la distance entre l’appareil et le récepteur. — Brancher l’appareil à une prise secteur différente de celle du récepteur. — Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs. Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant l’exposition aux RF, aucune modification apportée à l’antenne ou au dispositif n’est autorisée. Toute modification apportée à l’antenne ou au dispositif pourrait faire en sorte que le dispositif dépasse les exigences d’exposition aux RF et pourrait annuler le droit de l’utilisateur à utiliser ce dispositif.
Es
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria de Canadá aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las siguientes dos condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y (2) este dispositivo debe aceptar toda interferencia que reciba, incluso la que pudiera causar un funcionamiento no deseado. NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas modificaciones podrían anular la autoridad del usuario para utilizar el equipo. NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos límites están diseñados para proveer protección razonable contra interferencias perjudiciales en una instalación residencial. Este equipo genera, usa y puede irradiar energía de radiofrecuencias y, si no se instala y usa según las instrucciones, puede provocar interferencia perjudicial a las radiocomunicaciones. No obstante, no hay garantías de que no ocurrirá interferencia en una instalación en particular. Si este equipo provoca interferencia perjudicial a la recepción de radio o televisión, lo que puede determinarse encendiendo y apagando el equipo, se recomienda que el usuario intente corregir la interferencia por medio de la implementación de una o más de las siguientes medidas: — Reorientar o reubicar la antena receptora. — Incrementar la separación entre el equipo y el receptor. — Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que está conectado el
receptor. — Consultar al distribuidor o a un técnico con experiencia en radio/televisión para solicitar asistencia. Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
FCC — U2ZZW6306 | IC: 6924A-ZW6306
FCC — U2ZZW6306 | IC: 6924A-ZW6306 Jasco Products Company | Model: ZW6306 CAN ICES-3(B) / NMB-3(B)
All brand names shown are trademarks of their respective owners. Tous les noms de marque illustrés sont des marques de commerce de leurs propriétaires respectifs. Todas las marcas que aparecen aquí son marcas registradas de sus respectivos dueños.
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA GE IS A TRADEMARK OF GENERAL ELECTRIC COMPANY
AND IS UNDER LICENSE BY JASCO PRODUCTS COMPANY LLC, 10 E. MEMORIAL RD., OKLAHOMA CITY, OK 73114.
©JASCO 2018 | ZW6306 | rev. 06/06/18 PM v1
MANUAL • MANUEL • MANUAL
Portable
Smart
Flood/Freeze
Sensor
Détecteur de mouvement intelligent
portatif
READ IT OR WATCH IT
Sensor de movimiento
FPO
inteligente
portátil
ezzwave.com
Z-Wave® Certified Wireless Lighting Control Certifié Z-Wave Control inalámbrico para iluminación certificado por Z-Wave
®
Commande d’éclairage sans fil
Read instructions or watch easy-to-follow video.
Scan QR code or visit https://goo.gl/BPCB68.
Lea las instrucciones o mire este video sencillo.
Escanee el código QR o visite https://goo.gl/BPCB68.
Lisez les instructions ou regardez la vidéo
facile à comprendre. Balayez le code QR ou
visitez https://goo.gl/BPCB68.
®
ZW6306
DO NOT RETURN THIS PRODUCT TO THE STORE
NE RETOURNEZ PAS
STOP
CE PRODUIT AU MAGASIN NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
If you have any problems or questions, contact our tech support team at 1-800-654-8483, (option 1) Monday–Friday, 7:00am–8pm CST.
For the most up-to-date product support, accessories, electronic (PDF) format manuals and more, visit www.byjasco.com/support.
• No user serviceable parts in this unit. Si vous avez des problèmes ou des questions, communiquez avec notre
équipe de soutien technique au 1-800-654-8483, option 1, du lundi au vendredi, de 7 h à 20 h (HNC).
• Aucune des pièces de ce dispositif ne peut être réparée par l’utilisateur. Si tiene problemas o dudas, comuníquese con nuestro equipo técnico al número:
1-800-654-8483, opción 1 de lunes a viernes, de 7 a.m. a 8 p.m., hora estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios, manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
• FOR INDOOR USE ONLY
• BATTERIES MAY LEAK HARMFUL LIQUIDS
• DO NOT MIX OLD AND NEW OR
• REPLACE ALL BATTERIES AT THE SAME TIME
• REPLACE EXHAUSTED BATTERIES IMMEDIATELY
• REMOVE BATTERIES IF PRODUCT IS TO BE
• DO NOT USE Z-WAVE DEVICES TO CONTROL
• UTILISATION INTÉRIEURE UNIQUEMENT
• LES PILES PEUVENT LIBÉRER DES PRODUITS NOCIFS
• NE MÉLANGEZ PAS DES PILES NEUVES AVEC DES
• REMPLACEZ TOUTES LES PILES EN MÊME TEMPS
• REMPLACEZ IMMÉDIATEMENT LES PILES
• RETIREZ LES PILES DANS L'ÉVENTUALITÉ D'UNE
• N’UTILISEZ PAS LES DISPOSITIFS Z-WAVE POUR
This Device supports Lifeline and notification (association group 1) supporting 5
nodes. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this association automatically after inclusion. Lifeline association only supports the
“Device Reset Locally” function. Refer to the instructions of your controller for any
available details on how this can be set.
Cet appareil prend en charge la ligne de sécurité et la notification (groupe d’association
1) pour 5 noeuds. Au groupe 1 doit être attribué l’ID de nœud du contrôleur principal auquel seront envoyées des notifications non sollicitées. Le contrôleur Z-Wave doit régler automatiquement cette association après l’inclusion. L’association de ligne de sécurité prend seulement en charge la fonction «Device Reset Locally» (appareil réinitialisé localement). Reportez-vous aux instructions de votre contrôleur pour obtenir tous les détails disponibles sur la façon de le régler.
Este dispositivo es compatible con el grupo de asociación 1 de la red vital (Lifeline) y notificación, compatible con 5 nodos. Es compatible con 1 nodo para comunicación de la red vital. Al grupo 1 se debe asignar la Id. de nodo del controlador principal a donde se enviarán las notificaciones no solicitadas. El controlador Z-Wave debe configurar esta asociación automáticamente después de la inclusión La asociación de red vital solo es compatible con la función “dispositivo se reinicia a nivel local” Consulte las instrucciones de su controlador para obtener detalles sobre cómo realizar la configuración.
WARNING ADVERTENCIA
OR IGNITABLE MATERIALS OR EXPLODE CAUSING INJURY AND PRODUCT DAMAGE
OTHER BATTERY TYPES
UNUSED FOR EXTENDED PERIODS OF TIME
ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL
AVERTISSEMENT
OU DES SUBSTANCES INFLAMMABLES ELLES PEUVENT ÉGALEMENT EXPLOSER, CAUSANT DES BLESSURES OU DES DÉGÂTS MATÉRIELS
PILES USAGÉES OU DE TYPES DIFFÉRENTS
DÉCHARGÉES
LONGUE PÉRIODE DE NON-UTILISATION
COMMANDER LES RADIATEURS ÉLECTRIQUES OU D’AUTRES APPAREILS QUI POURRAIENT PRÉSENTER UN DANGER EN CAS DE COMMANDE D’ACTIVATION IMPRÉVUE, INVOLONTAIRE OU AUTOMATIQUE
• SOLO PARA USO EN INTERIORES
• LAS PILAS PUEDEN PERDER LÍQUIDOS PERJUDICIALES O MATERIALES INFLAMABLES, O BIEN EXPLOTAR Y CAUSAR LESIONES CORPORALES Y DAÑOS EN LOS PRODUCTOS
• NO COMBINE PILAS VIEJAS Y NUEVAS, NI TIPOS DE PILAS DISTINTAS
• REEMPLACE TODAS LAS PILAS AL MISMO TIEMPO
• REEMPLACE LAS PILAS AGOTADAS DE INMEDIATO
• EXTRAIGA LAS PILAS SI NO UTILIZA EL PRODUCTO DURANTE PERÍODOS EXTENDIDOS
• NO USAR LOS DISPOSITIVOS Z-WAVE PARA CONTROLAR CALENTADORES ELÉCTRICOS U OTROS APARATOS ELECTRODOMÉSTICOS QUE PUDIERAN IMPLICAR UN PELIGRO DEBIDO A UN ENCENDIDO SIN SUPERVISIÓN, ACCIDENTAL O AUTOMÁTICO
NOT FOR USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER BE USED TO SUPPLY POWER TO, OR CONTROL THE ON/OFF STATUS OF MEDICAL AND/OR LIFE SUPPORT EQUIPMENT.
NE PAS UTILISER AVEC UN ÉQUIPEMENT MÉDICAL OU DE SURVIE
LES DISPOSITIFS COMPATIBLES AVEC LA TECHNOLOGIE Z-WAVE NE DEVRAIENT JAMAIS ÊTRE UTILISÉS POUR ALIMENTER OU COMMANDER LA MISE EN MARCHE OU L’ARRÊT DE L’ÉQUIPEMENT MÉDICAL OU DE SURVIE.
SE PROHÍBE SU EMPLEO EN EQUIPO MÉDICO O EQUIPO PARA EL MANTENIMIENTO DE LAS FUNCIONES VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN USAR PARA SUMINISTRAR ENERGÍA ELÉCTRICA AL EQUIPO MÉDICO O AL EQUIPO PARA EL MANTENIMIENTO DE FUNCIONES VITALES, NI PARA CONTROLAR EL ESTADO DE ENCENDIDO O APAGADO DE DICHOS EQUIPOS.
WARRANTY
JASCO Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. Please contact Customer Service at 800-654-8483 (option 1) between 7AM – 8PM CST or via our website (www.byjasco.com) if the unit should prove defective within the warranty period.
GARANTIE
JASCO Products garantit que ce produit est exempt de tout défaut de fabrication pour une période de deux ans à compter de la date de l’achat original par l’acheteur. Cette garantie se limite exclusivement à la réparation ou au remplacement de ce produit et n’est pas applicable aux dommages indirects ou accessoires survenus sur d’autres produits utilisés avec ce produit. Cette garantie se substitue à toute autre garantie expresse ou implicite. Certains États ne permettent pas de restrictions quant à la durée d’une garantie implicite ou permettent l’exclusion ou la limitation des dommages indirects et accessoires; il se peut, par conséquent , que cette garantie ne s’applique pas dans votre cas. Cette garantie vous confère des droits juridiques précis; vous pouvez jouir d’autres droits qui peuvent varier d’un État à l’autre. Veuillez communiquer avec le service à la clientèle au 1-800-654-8483 (option 1) entre 7 h et 20 h (heure normale du Centre) ou par l’intermédiaire de notre site web (www.byjasco.com) si l’appareil s’avère défaillant au cours de la période de garantie.
GARANTÍA
JASCO Products garantiza que este producto está libre de defectos de fabricación durante un periodo de dos años a partir de la fecha original de compra por parte del consumidor. Esta garantía se limita a la reparación o sustitución de este producto solamente y no se extiende a daños derivados o accidentales causados a otros productos que se usen con esta unidad. Esa garantía remplaza a todas las demás garantías expresas o implícitas. Algunos estados no autorizan limitaciones en cuanto a la duración de una garantía implícita ni permiten la exclusión o limitación por daños accidentales o derivados; por lo tanto, puede que las anteriores limitaciones no apliquen en su caso. Esta garantía le da a usted derechos específicos, y otros que usted puede tener y que varían según el estado en el que usted reside. Si la unidad resultare defectuosa dentro del periodo de garantía, comuníquese por favor con Atención al Cliente en el 800-654-8483 (opción 1) entre 7 y 20 h, Hora del Centro, o a través de nuestro sitio de internet (www.byjasco.com).
JASCO Products Company LLC, Building B 10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
Power: (1) CR123A Batteries (included); USB power option 5V/500mA (not included) Signal (Frequency) 908.4 / 916 MHz PIR Range: up to 180° PIR Distance: up to 45 feet Z-Wave Range: Up to 150 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module. Operating Temperature Range: 32–104° F (0–40° C). For indoor use only. Specifications subject to change without notice due to continuing product improvement.
SPÉCIFICATIONS
Alimentation : (1) pile CR123A (incluses); option d’alimentation par connexion USB 5 V/500 mA (non inclus) Signal (fréquence) 908,4 / 916 MHz Portée PAR : Jusqu’à 180 ° Distance PAR : Jusqu’à 45 pi Portée Z-Wave : Distance à vue entre la télécommande et le module de réception Z-Wave le plus proche allant jusqu’à 150 pi. Plage de températures de fonctionnement : De 32 à 104 °F (de 0 à 40 °C). Utilisation intérieure uniquement. En raison d’améliorations continues du produit, les spécifications peuvent faire l’objet de changements sans préavis.
ESPECIFICACIONES:
Alimentación: una (1) pila CR123A (incluidas); alimentación por USB 5v/500mA (no incluido) Señal (frecuencia) 908,4/916 MHz Alcance del sensor infrarrojo pasivo: hasta 180° Distancia del sensor infrarrojo pasivo: hasta 45 pies (13,7 m) Alcance de Z-Wave: Hasta 150 pies (45,7 m) en línea recta entre el controlador inalámbrico y el módulo receptor Z-Wave más cercano. Rango de temperatura de funcionamiento: 32-104 °F (0-40 °C) Para uso en interiores exclusivamente. Las especificaciones están sujetas a cambios sin previo aviso por las constantes mejoras a las que se someten los productos.
Accessories • Accessoires • Accesorios
13473
USB Power Adapter
To purchase compatible accessories, visit www.byjasco.com/USB Pour acheter des accessoires compatibles, visitez www.byjasco.com/USB Para comprar accesorios compatibles, visite www.byjasco.com/USB
37028
9ft. Micro USB Cable
1.
Getting to know your new Z-Wave device
• Z-Wave certified for simple pairing and integrated home automation • Transmits notifications to connected controller when leaks or changes in area
temperature are detected
• Dual detection options — contacts on the sensor base or separate plug-in detection probe for hard to reach locations
• Red LED indicates programming changes and status
• Alarm for separate audible notification of leaks
• Supports association with up to five devices
• Easy auto pairing and button-press settings
• Automatic tamper switch with alarm
• Regular battery level reports
2.
A. LED – blue, red and purple behind cover B. Programming button C. Probe port D. Micro USB cable port E. Battery and battery tab F. Top cover locking tab G. Alarm siren H. Top cover I. Detachable probe
H
E
G
F
A
B
D
C
NOTE: The Smart Motion Sensor has dual power options – it can be powered by batteries (included) or USB (adapter and cable sold separately).
When powered by batteries, the signal repeater function is disabled to conserve battery power. When powered by USB, the
OR
signal repeater function is active and will help to extend your Z-Wave network.
Battery Power USB Power
Installation
3.
I
The Smart Flood/Freeze sensor is designed for indoor use only. Place the sensor (typically in battery power mode) near the area of potential leaks or water source – under sinks, behind commodes, dishwashers, washing machines, hot water tanks, etc. the sensor can be placed on the floor, cabinet base, etc. so the three pins on the bottom can come in contact with the water leak. The contact pins are slightly reduced so that they do not come in contact with the surface (see Figure 1). The sensor can be safely place onto a metal surface without activating the sensor. Mounting tape (included) can be applied to the bottom of the sensor to secure it to the floor or cabinet base to prevent it from being accidently moved (see Figure 2).
For hard to reach locations (i.e. not enough room for the sensor to be placed on the floor or surface), use the mounting tape to attach the sensor to the wall. Open the port to insert the detachable probe (see Figure 3). Secure into position with the pins pointed down using smaller mounting tape (included) (see Figure 4).The contact pins are slightly reduced so that they do not come in contact with the surface (see Figure 5).
Figure 4
Figure 3
For continuous power connect an optional micro USB cable to the power port and plug into any USB 5v power supply (see Figure 6). Optional USB cable and USB power supply available at ezzwave.com
Figure 5
Figure 1
Recessed contact pins
Contact pins
Figure 2
Figure 6
4.
Adding your sensor in a Z-Wave network
The Flood/Freeze sensor can be added to the Z-Wave network automatically or manually, from battery power or USB power. For best results, add the sensor to the network near the intended location (same room or area) to ensure best communication routes are established.
Automatic Mode Battery power
1. Follow the instructions for your Z-Wave certified controller to add the sensor in the Z-Wave network.
2. Once the controller is ready to add your sensor, press one the side buttons, then, press in the opposite side button. Remove the top (see Figure 7).
3. Remove the plastic battery tab (see Figure 8). This activates the sensor and starts the auto add process.
4. The red LED will begin to flash quickly as it searches for a network. The sensor will attempt to search for a network for two minutes, after which it will time out .
5. The red LED will continue to flash quickly when it locates a network – the controller ’s app will indicate if it has discovered the sensor. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box, or the QR code label on the product (see below). Enter the 5-digit code.
DSK : XXXXX
-125651-22671
-26939-47599
-19612-25872
6. The red LED will activate for 3 seconds to confirm the sensor has been added in the network. Secure the top cover into place. USB power
1. Follow the instructions for your Z-Wave certified controller to add the sensor in the Z-Wave network.
2. Once the controller is ready to add your sensor, open the USB port rubber gasket and insert the micro USB plug into the USB port (see Figure 9).
3. The red LED will begin to flash quickly as it searches for a network. The sensor will attempt to search for a network for two minutes, after which it will time out.
4. The red LED will continue to flash quickly when it locates a network – the controller’s app will indicate if it has discovered the sensor. If prompted by the controller to enter the S2 security code, refer to the QR code/S2 security
5. The red LED will activate for 3 seconds to confirm the sensor has been added in the network. Secure the top cover into place.
Manual Mode
1. Follow the instructions for your Z-Wave certified controller to add the sensor in the Z-Wave network.
2. Once the controller is ready to add your sensor, remove the top cover of the sensor. Ensure battery is installed with the correct polarity and the battery tab has been removed.
3. Press and release the programming button (see Figure 10). This starts the manual add process. The red LED will begin to flash quickly as it searches for a network. The sensor will attempt to search for a network for two minutes,
4. The red LED will continue to flash quickly after it locates a network – the controller’s app will indicate if it has discovered the sensor. If prompted by the controller to enter the S2 security code, refer to the QR code/security
5. The red LED will activate for 3 seconds to confirm the sensor has been added in the network. Secure the top cover into place. Note: your controller may need to be within 10 feet of the sensor to be added.
Now you have complete control to activate groups, scenes, schedules and interactive automations when the sensor detects a leak. Functions may vary depending on gateway or controller.
To remove the sensor from the Z-Wave network
1. Follow the instructions for your Z-Wave certified controller to remove the sensor from the Z-Wave network.
2. Once the controller is ready to remove your sensor, press and release the programming button on the sensor (see Figure 10) to
3. The red LED will blink 5 times to indicate it has been removed. Secure the top cover into place.
-47752
number on the back of the box, or the QR code label on the product (see below). Enter the 5-digit code.
DSK : XXXXX
-125651-22671
-26939-47599
-19612-25872
-47752
Battery Power
after which it will time out. If it times out , the LED will stop flashing. Press and release the programming button again.
number on the back of the box, or the QR code label on the product (see below). Enter the 5-digit code.
DSK : XXXXX
-125651-22671
-26939-47599
-19612-25872
-47752
remove it from the network.
To return the sensor to factory defaults (will also remove sensor from Z-Wave network)
1. Press the programming button 10 times within 6 seconds (interval between presses of the button cannot be longer than 1 second).
2. The red LED will activate for 2 seconds, followed by 3 quick flashes. This confirms the sensor has been reset. Secure the top cover into place.
To replace battery
1. Remove the top cover (see Figure 7).
2. Remove old battery and replace with new battery. When installing new battery, ensure proper polarity.
3. Secure top cover.
Figure 9
Figure 7
Figure 8
Figure 10
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Loading...