Sharper Image 206148 User Manual

Page 1
3-D ULTRASONIC AROMATHERAPY DIFFUSER
Item No. 206148
User Guide
Thank you for purchasing the Sharper Image 3-D Ultrasonic Aromatherapy Diffuser. Please take a moment to read this guide and store it for future reference.
- 1 -
Page 2
INTRODUCTION
IDENTIFICATION OF PARTS
1. Glass cover
2. Water tank cover spout
3. Water tank cover
4. Water tank
5. 1-hour timer light
6. LED button
7. Water tank capacity label
8. 2-hour timer light
9. Power indicator light
10. Power button
11. AC adapter
BUTTON FUNCTIONS
Power button: Select continuous mist or one of two automatic shutoff timers
• Press 1 time = continuous mist + color-changing LED light mode
• Press a second time = 2-hour shutoff timer + color-changing LED light mode
• Press a third time = 1-hour shutoff timer + color-changing LED light mode
• Press a fourth time = mist is turned off and LED light is turned off
LED Button: Select color-changing light mode (the default setting) or a solid color. Note: Each solid color has a “high” and “low” setting.
The sequence is as follows:
Color-changing mode (default) > Purple (high) > Purple (low) > Yellow (high) > Yellow (low) > Blue (high) > Blue (low) > Green (high) > Green (low) > Cyan (high) > Cyan (low) > White (high) > White (low) > back to Color-changing mode
Press and hold the LED button for 3 seconds to turn off the light. The diffuser will continue to produce mist without light.
- 2 -
Page 3
OPERATING THE 3-D ULTRASONIC AROMATHERAPY DIFFUSER
1. Remove the glass cover and water tank.
2. Put water into the water tank (maximum 3 oz./100ml). Do not use any other liquid.
3. Add 3-5 drops of essential oil to the water (essential oil not included).
4. Replace the water tank cover and the glass cover.
5. Plug in the device and press the Power button to operate.
6. When device is in use or filled with water, make sure it is on a flat, level surface.
CARE AND MAINTENANCE
1. Before cleaning or maintenance, make sure the device it turned off and unplugged.
2. Remove the glass cover and water tank.
3. Pour out water, making sure that you do not get water into the motor or air outlet. If water does get into the air outlet or motor, place the device in a ventilated area and let it dry out for at least 3 days.
4. Use a clean swab or soft cloth to gently clean the device.
TROUBLESHOOTING
Problem Reason Solution
No Mist
Not connected to power source.
No water or water below the minimum level.
Overfilled with water (over 3 oz./100 ml).
Atomization plate is covered by scale.
Connect to power source and press the power button.
Put appropriate water into the water tank.
Pour out excess water, making sure that you do not get water into the motor or air outlet.
Clean the scale in the atomization plate.
Top cover or water cover mist vent is clogged.
Use a swab to clean mist vent and keep the mist vent clean.
SHOPPING FOR ESSENTIAL OIL?
Sharper Image offers a variety of top quality essential oils for your aromatherapy diffuser. Visit SharperImage.com to choose Cinnamon, Lavender, Eucalyptus and more (Item No. 201106).
- 3 -
Page 4
SPECIFICATIONS
Product Model No 206148
Product Size 3.7 x 10.2 in.
Voltage DC24V
Power 10W
Water Capacity 100ML
WARRANTY / CUSTOMER SERVICE
Sharper Image branded items purchased from SharperImage.com include a 1-year limited replacement warranty. If you have any questions not covered in this guide, please call our Customer Service department at 1 (877) 210-3449. Customer Service agents are available Monday through Friday, 9:00 a.m. to 6:00 p.m. ET.
The SHARPER IMAGE® name and logo are registered trademarks.
©Sharper Image. All Rights Reserved.
- 4 -
Loading...