SHARP SP2306 Technical Report

COPIER : SF-2025
Date
:
Jul. 10, 1998
No. : SP-2306
MEASURE TO ALLEVIATE PROBLEMS OF OFF-CENTER ADJUSTMENT ERRORS IN THE ADU UNIT.
1.Model Name: SF-2035/2025/2030/2040
2.General: There was a problem which occurred during off-center adjustment operations which
were carried out during connection operations of the ADU unit. The off-center adjustment operations could not be carried out due to contact between the ADU unit and the PWB support attached in the machine. As a measure to alleviate this problem, the action described below has been carried out.
established as a service part. If off-center adjustment operations cannot be carried out due to the problem described above with the PWB support, replacement operations of the PWB support should be carried out as described below.
Newly established PWB support
LSUPP0111FCZZ
Rear frame
PWB support of the mirror PWB (4 locations) (SF-2035) PWB support of the DH relay PWB (3 locations) (SF-2025/2030/2040)
This action is to be carried out for models produced before 1997 October production. For models produced after 1997 October production, a change has been carried out in the shape of the ADU unit.
SHARP CORPORATION Reprography Division
1/2
Green
C
Ref.
Model
No.
SF-2035 SF-2025
SF-2030 SF-2040
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
All ---- ---- LSUPP0111FCZZ AD PWB supporter ---- 6
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Price
rank
Parts name
Effec-
tive
time
Inter-
change-
ability
Note
2/2
Loading...