SHARP SP2301 Technical Report

COPIER : SF-2025
Date
:
Jul. 16, 1998
1. CHANGE IN THE FUSING HARNESS CARRIED OUT AS A MEASURE TO COMPLY WITH SAFETY STANDARDS.
2. MEASURE TO PREVENT PROBLEMS OF LOOSE TAB TERMINALS.
3. DISCONTINUANCE OF SCREWS IN THE OPTICAL UNIT CARRIED OUT AS A MEASURE TO IMPROVE PRODUCTIVITY.
No. : SP-2301
1. Change in the fusing harness carried out as a measure to comply with safety standards.
1.Model Name: SF-2040 (only for machines bound for the 200 V series market destinations)
has been carried out as a measure to comply with safety standards.
3.Description: A change has been carried out in a portion of the coloring of the wires and in the
position of the pins of the drawer connector.
The color has been changed to white.
Added marking (black)
The color has been changed to white.
4.Action: From the start of 1998 June production.
2. Measure to prevent problems of loose tab terminals.
1.Model Name: SF-2025/2030/2040/2052
2.General: A change has been carried out in the support tab terminals for the PWB. This action
3.Action: From the start of 1998 June production.
has been carried out as a measure to prevent problems of looseness in the tab terminals of the AC circuit PWB.
SHARP CORPORATION Reprography Division
1/2
Green
C
3. Discontinuance of screws in the optical unit carried out as a measure to improve productivity.
1.Model Name: SF-2025/2030/2040
2.General: A portion of the screws used in the optical unit have been discontinued. This action has
been carried out as a measure to improve productivity.
Discontinued
3.Action: From the start of 1998 June production.
Ref.
Model
No.
1 SD-2040
SF-2025 SF-2030
2
SF-2040 35 -10
SF-2052
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
200V
18 -62 DHAI-2197FCZZ DHAI-2968FCZZ AU
series
36 -10
All
55 -15
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
QTANP0193FCZZ QTANP0209FCZZ AC Tab terminal
Effec-
Price
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Parts name
rank
Fusing interface harness
tive
time
1st lot
'98/6
Inter-
change-
ability
3
Note
2/2
Loading...