No. : SP-2242
CHANGE CARRIED OUT IN THE FIXING SCREWS OF THE ELECTRODE IN THE TC CASE UNIT.
1.Model Name: SF-2035/1125/2025/2030/2040
2.General: There was a possibility of contact between the fixing screws used to secure the
electrodes in the R portion of the TC holder in the TC Case unit and the bottom portion of the case. As a measure to alleviate this problem, a change has been carried out in the length of the fixing screws.
M3 ×8!has ×6
3.Action: Running change from 1997 mid-November production.
SHARP CORPORATION Reprography Division
ged to M3
There was a possibility of the fixing screws coming in contact with this portion.
1/2
Green
C
Ref.
Model
No.
SF-1125 SF-2025 SF-2030
SF-2035 SF-2040
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with ‘ ’’ is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
26 -4
All
25 -4
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
XBPSD30P08000 XBPSD30P06000 AA Screw (M3 × 6)