Date: Jan. 20, 1998
Copier SF-2050/2052
No. : SP-2236
1.2.Countermeasure against shrinkage in the developing section for
both-side copying
Countermeasure against abnormal noise from optical unit
1. Prevention of harness damage
1. Model Name: SF-2050/2052/2150
2. General: As the countermeasure against shrinkage in the developing section for both-side copying, the
nipping stroke adjusting value (the normal value only) of the curl correcting unit is changed.
Before change After change
3. Action:
AB size system
Inch size system 5.8 ± 0.1mm
SF-2050 → 1st product of October, 1997
5.6 ± 0.1mm
→
→
5.7 ± 0.1mm
5.9 ± 0.1mm
SF-2052/2150 → 1st mass-produced product
2. Change of screws which combine the fixture frame
1. Model Name: SD-2050/2052/2150
2. General: As the countermeasure against abnormal noise from optical
3. Action:
SHARP CORPORATION Reprography Division
SF-2050 → 1st duct of October, 1997
SF-2052/2150 → 1st mass-produced product
Green