SHARP sp2188 Technical Report

COPIER : SF-2120
Date
:
Oct. 23, 1997
1. MEASURE TO ALLEVIATE PROBLEMS OF MOVEMENT ERRORS OF THE TURN-OVER GATE.
2. CHANGE CARRIED OUT IN THE ATTACHMENT SCREWS USED IN THE ADU UNIT.
1. Measure to alleviate problems of movement errors of the turn-over gate.
1.Model Name: SF-2120/1120
2.General: There have been problems of movement errors which arose when bending occurs in the
turn-over gate causing it to obstruct the cabinet. As a measure to alleviate this problem, a change in the shape of the turn-over gate has been carried out.
No. : SP-2188
3.Description: The marked portions in the figure below have been removed (these portions were
causing the obstruction of the cabinet).
4.Action: From 1997 mid-July production.
SHARP CORPORATION Reprography Division
1/2
Green
C
2. Change carried out in the attachment screws used in the ADU unit.
1.Model Name: SF-2120/1120
2.General: A change in the attachment screws used in the ADU unit has been carried out. The 4 × 8
type attachment screws were changed to 4 × 4 type attachment screws. This action was carried out as a measure to improve productivity.
3.Action: From the 1st lot of 1997 August production.
Ref.
Model
No.
SF-2120
1
SF-1120 SF-2120
2
SF-1120
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with ‘ ’’ is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
5 -9
All
25 -8
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
PGIDM1733FCZZ PGIDM1733FCZ1 AN Turn over gate
XHBSD40P08000 XHPSD40P04000 AA Screw (4 × 4)
Effec-
Price
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Parts name
rank
tive
time
Mid-
’97/7
1st lot
’97/8
Inter-
change-
ability
3
Note
2/2