SHARP SP2162 Technical Report

COPIER(OPTION) : SF-S55/A17
Date
:
Aug. 1, 1997
1. CHANGES CARRIED OUT AS A MEASURE TO IMPROVE PRODUCTIVITY.
2. MEASURE TO ALLEVIATE PROBLEMS OF THE FIXING SCREW OF THE ADF OPENING AND CLOSING SWITCH BECOMING LOOSE.
No. : SP-2162
1. Changes carried out as a measure to improve productivity.
1.Model Name: SF-S55
2.General: The measures described below have been carried out to improve productivity, to
improve the rotation strength of the inlet roller, and to improve the performance of the paper detection sensor of the stapler.
3.Description: (1) The method of securing the inlet roller in the transport unit has been changed.
The press fit method of securing the inlet roller has been changed to a straight pin and E-ring. This change has been carried out as a measure to improve the revolution strength of the shaft and the inlet roller.
(Old)
Press fit
Shaft
Roller
(New)
E-ring
Straight pin
Shaft
Roller
(2) A change has been carried out in a resistor in the main control PWB (R95 only).
This change has been carried out as a measure to improve the light projecting volume so that adjustments can be made even with a low-sensitive light sensor in the paper detection sensor section of the stapler.
(3) A change has been carried out in the LED and the pin. This change has been carried
out in accordance with the automatic insertion of parts in the main control PWB.
(4) A change has been carried out in the capacitor. This change has been carried out in
accordance with the automatic insertion of parts in the pin shift motor driver PWB.
4.Action: (1) From the 1st lot of 1997 June production.
(2) From 1997 mid-February production. (3) From 1997 mid-May production. (4) From the 1st lot of 1997 April production.
SHARP CORPORATION Reprography Division
1/2
Green
C
2. Measure to alleviate problems of the fixing screw of the ADF opening and closing switch becoming loose.
1.Model Name: SF-A17/A56/A18/A57
2.General: There was a problem of the fixing screw of the ADF opening and closing switch
becoming loose due to the fact that the screw was too short. As a measure to alleviate this problem a change has been carried out in the fixing screw. The new screw is longer than the old one.
3.Action: From the 1st lot of 1997 June production.
Ref.
Model
No.
1
SF-S55 All
(1)
1
(2)
1
(3)
1
(4)
SF-A17 SF-A56
2
SF-A18 SF-A57
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with ‘ ’’ is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
5 -30
14 -87 0GZVV16148331 0GZVV16148221 AB Resistor [R95]
14 -46
14 -47 0GZWG15089000 0GZWG25057000 LED [LED7/9-11]
14 -18 0GZWT10337000
14 -19
14 -20 0GZWT10211000 Pin [CP3-6/16/21/22/24/27/28]
14 -21
17 -1
1 -42
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
0GZFB30060000 0GZ4G10404000 BA Inlet roller
0GZWG10157000 0GZWG10373000
0GZWT10122000 Pin [CP2]
0GZWT10334000 Pin [CP7-14/17-20]
0GZVC73970127 0GZVC83040227 AF Capacitor [C601]
0CW023100FZNS 0CW02310FBWS AB Screw (2.3 × 12)
0GZFH90186000 AC
Price
rank
AD
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Parts name
LED [LED1-6/8]
Pin [CP1/25/26]
Effec-
tive
time
1st lot
’97/6
Mid-
’97/2
Mid-
’97/5
1st lot
’97/4
1st lot
’97/6
Inter-
change-
ability
3
4
1
3
Note
330
220
2/2
Loading...