SHARP SP2159 Technical Report

COPIER : SF-2050
Date
:
Jul. 11, 1997
1. MEASURE TO PREVENT DAMAGE FROM OCCURRING TO THE DRAWER CONNECTOR IN THE DRUM DRIVE UNIT SECTION.
2. MEASURE TO ALLEVIATE PROBLEMS OF JAMS IN THE ADU UNIT.
3. MEASURE TO ESTABLISH INTERCHANGEABILITY OF PARTS BETWEEN MODELS CARRIED OUT AS A MEASURE TO IMPROVE PRODUCTIVITY.
4. MEASURE TO IMPROVE OPERATIONABILITY AFTER THE MACHINE HAS BEEN CLEARED OF JAMS.
5. CHANGE IN THE SHAPE OF PARTS AND CHANGE IN MATERIALS CARRIED OUT AS A MEASURE TO IMPROVE PRODUCTIVITY.
No. : SP-2159
1.Model Name: SF-2050
2.General: There was a problem of damage sometimes occurring to the drawer connector. The
damaged was caused because the insertion hole for the drawer connector of the DV joint in the drum drive unit was too small. As a measure to alleviate this problem the hole has been slightly enlarged. In addition to the change described above, a change has been carried out in the shape of a portion of the attachment plate for the main PWB. This change has been carried out as a measure to establish interchangeability between the model listed above and other models.
DV joint plate D
Added marking
3.Description:
The dimensions have been enlarged 1.5.
The dimensions have been widened 1 mm.
Abnormally shaped hole
The dimensions have been widened 1 mm.
The dimensions have been widened 1 mm.
4.Action: From 1997 mid-June production.
Added hole for the PWB supporter (in two locations).
1/4
SHARP CORPORATION Reprography Division
Green
C
2. Measure to alleviate problems of jams in the ADU unit.
1.Model Name: SF-2050
2.General: There was a problem of copy paper jams sometimes occurring especialy on the
inch-size papers. This problem was caused because the space between the fixing plate and the standard plate of the ADU unit was too small. As a measure to alleviate this problem, a change has been carried out in the shape of the fixing plate to increase the space.
Fixing plate assembly (CPLTM4939FC01-02)
3.Description:
Cut 2 mm
Cut 2 mm
4.Action: From 1997 mid-June production.
3. Measure to establish interchangeability of parts between models carried out as a measure to improve productivity.
1.Model Name: SF-2050
2.General: A change has been carried out in the shape of some of the parts that are used in the
fusing unit. This change has been carried out as a measure to establish interchangeability of the parts between the model listed above and other models.
3.Description:
Fusing R lower frame
FU rear lower paper guide
Fusing F lower frame
Added notch
4.Action: From 1997 mid-June production.
2/4
A change has been carried out in the width of the notches.