COPIER : SF-2050
No. : SP-2146
PREVENTING JAMS WHEN USING THE RADF
1.Model Name: SF-2050
2.General: When the RADF is used, static electricity on the table glass may cause paper jams. We
have begun using table glass with a conductive coating to prevent this problem.
3.Description:
Rear side
Table glass
Side marking
Before change:White
After change: Yellow
Front side
4.Action: From the middle of April, 1997 production on.
Ref.
Model
No.
SF-2050 All
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with ‘‘ ’’ is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
1 -32
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
PGLSP0074FCZ3 PGLSP0074FCZ6 BN Table glass
Effec-
Price
5. Interchangeable if replaced with same types of
related parts in use.
6. Others.
Parts name
rank
tive
time
Mid-
’97/4
Inter-
change-
ability
3
Note
SHARP CORPORATION Reprography Division
Green
C