COPIER : SF-2020
No. : SP-2125
1.MEASURE CARRIED OUT TO IMPROVE THE HEAT RESISTANCE
OF THE DC PWB.
2.MEASURE CARRIED OUT TO PREVENT LEAKING.
1. Measure carried out to improve the heat resistance of the DC PWB.
1.Model Name: SF-2020/1020/2120/1120
2.General: The changes described below have been carried out in the DC PWB of the models
listed above.
1) An increase in the capacity of the aluminium electrolytic capacitor has been carried
out as a measure to minimize the voltage fluctuation caused by the load fluctuation
which occurs when a power reduction occurs in the input power supply.
2) Changes and additions of parts were carried out, including the cooling plate. This
change was carried out as a measure to improve the heat resistance of the PWB to
compensate for the rise in temperature of the terminals.
DC Protective plate
Hound DC PWB cooling
plate A
DC Protective mylar
PSHEP4404FCZZ
XBPSD30P08KSO
DC Protective plate
DC PWB cooling plate C
DC
Hound DC PWB cooling
plate B
DC PWB
3.Action: From 1996 November production.
SHARP CORPORATION Reprography Division
1/2
Green
C
2. Measure carried out to prevent leaking.
1.Model Name: SF-2116/1016/2118/1018/2020/1020/2120/1120
2.General: A change has been carried out in the high voltage harness of the drive unit. This action
has been carried out as a measure to prevent leaking in the models listed above.
Furthermore, in accordance with this change the part code of the drive frame has also
been changed, but the part code due to skating is different.
3.Action: SF-2020/1020/2120/1120: From 1997 March production.
SF-2116/1016/2118/1018: Running change from 1997 March production.
Ref.
Model name Version P/G No.
No.
1
SF-2020/2120
SF-1020/1120
Overseas
SF-2116/2118
SF-1016/1018
2
SF-2020/2120
SF-1020/1120
SF-2020
SF-2120
Skating A area 12 -1 CFRM-0836FC71 CFRM-0836FC75
Skating B area 19 -901 CFRM-0836FC72 CFRM-0836FC76
SEEG
U.K.
Australia
New Zealand
Current parts New parts
Parts code Parts code
40 -12 VCEAEW1EC152M VCEAEW1EC222M AF Electrolytic capactor
40 -3 PRDAR0067FCZZ PRDAR0078FCZZ AK DC PWB cooling plate A
40 -4
40 -5 PRDAR0069FCZZ PRDAR0080FCZZ AK DC PWB cooling plate C
40 ----
12 -44
19 -7
11 -44
18 -7
12
19
PRDAR0068FCZZ PRDAR0079FCZZ AL DC PWB cooling plate B
Q’ty Change
XBPSD30P08KS0
NEW
PSHEP4404FCZZ
DHAI-2423FCZZ DHAI-2788FCZZ AS High voltage harness
----
NEW
CFRM-0836FC74
Price
rank
AA Screw
AE DC Protective mylar
BT Drive frame
Parts name
Effec-
tive
time
1 st lot
’97/11
∗1 3
Inter-
change-
ability
3
5
Note
2/2
SF-2116/2118
SF-1016/1018
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
Parts marked with ‘‘ ’’ is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Skating A area 11 -1 CFRM-0836FC71 CFRM-0836FC75
Skating B area 19 -901 CFRM-0836FC72 CFRM-0836FC76
5. Interchangeable if replaced with same types of
related parts in use.
6. Others.