Date: Nov. 22, 1996
COPIER : SF-2014
No. : SP-2076
PREVENTING THE TEMPERATURE FUSE IN
THE OPTICAL UNIT FROM BLOWING.
1.Model Name: SF-2014/21 14/2214
SN-1420/1430 (US version only), Z-800 (USA, SEEG versions only)
2.General: The temperature fuse may blow if the temperature in the optical unit rises too high.
To avoid this problem, we have taken the following steps to prevent overheating of the
optical unit.
3.Description:
Fixed fuse (discontinued)
4.Action: From the middle of October, 1996 production on.
CFM louver (discontinued)
SHARP CORPORATION Reprography Division
1/2
Green
C
Ref.
Model
No.
SF-2014
SF-2114
SF-2214
SN-1420
SN-1430
Z-800
SN-1420
SN-1430
Z-800
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. C urr e nt t y pe c a n be u s ed i n p la ce of new t ype.
New ty pe cann ot be us ed i n place of curr ent type .
3. C urre nt ty pe cann ot be used i n place of new ty pe.
New t y pe c a n be u sed in p la c e of c u rr en t ty p e.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
name
Version P/G No.
6 -104
All
U.S.A.
U.S.A.
SEEG
U.S.A.
U.S.A.
SEEG
only
only
only
only
8 -104
7 -104
8 -105
7 -105
!
Current parts New parts
Parts code Parts code
MLOVP0005FCZZ
Discontinued —
XEBSE40P08000 Screw (M4 x 8)
Price
5. Interchangeable if replaced with same types of
relate d parts in use .
6. Others .
Parts name
rank
CFM louver
Effec-
tive
time
Mid-
’96/10
Inter-
change-
ability
6
Note
2/2