2. REGARDING BLACK STREAKS / HUMIDITY IN THE DV UNIT AND CROOKED HOLDER MR
ATTACHMENT.
3. MEASURE TO PREVENT THE HARNESS FROM BEING PINCHED.
4. MEASURE TO PREVENT THE SOLENOID ATT A CHMENT PLATE FROM DISTORTING.
No. : SP-1993
1. IC damage prevention and BL error prevention.
1.Model name:SF-2025/2030/2040
2.General:Diodes have been added to the main PWB as a measure to improve the problems
described below.
(1) T o prevent damage to the IC due to the ADF connector insertion when the machine
is turned ON.
(2) To prevent BL error flashing due to high voltage leaks.
(3) Circuit additions in accordance with the addition of a DFM. (This measure has been
carried out only on model SF-2040.)
3.Description:Measure for problems (1) and (2) described above.:
Diodes (VHD1SS133//-1) have been added to the main PWB.
Added location → D134, D135, D136, D138 have been silk screened.
Measure for problem (3) described above. (carried out only on model SF-2040):
A diode (VHDDSM1D1//-1) has been added to the main PWB.
Added location → D137 has been silk screened.
The silk screening on the main PWB has been changed in accordance with the
changes described above.
N1133FC-1 → N1133FC-2
4.Action:From the start of 1996 February production. (Back side attachment of the above parts
has been carried out as a temporary measure since the start of mass production.)
SHARP CORPORATIONReprography Division
1/4
Green
C
2. Regarding black streaks / humidity in the DV unit and crooked holder MR
attachment.
1.Model name:SF-2025/2030/2040
2.General:(1) The shape of cover D of the DV unit has been changed in order to eliminate black
streaks and alleviate rising temperatures.
OldNew
Side F of cover D
Side R of cover D
(2) The shape of box D of the DV unit has been changed in order to improve looseness
in the attachment of holder MR and eliminate bit insertion misses.
Measure to improve looseness in the attachment of holder MR.
Measurements of section A
Old New
Side R of box D
0.05
ø20+
0
→ ø19.95+
0.05
0
Measure to eliminate bit insertion misses
Diagram of the top face of box D
The change in bit insertion was carried out at the location indicated
by the circles in the diagram.
Note:There are three other locations where the change described in above was carried
out, but only a representative example of the change has been shown in this report.
3.Measure to prevent the harness from being pinched.
1.Model name:SF-2025/2030/2040
2.General:When OR guide R (P/G ) is attached during production operations, the is a danger
1 -34
of the harness connecting the operation panel with the main PWB being pinched when
being secured. To alleviate this danger the measure described below has been carried
out.
3.Description:The harness protect sheet has been changed to one with double-sided tape attached to
the upper surface. The harness is secured by the double-sided tape on the upper
surface of the harness protect sheet, preventing it from being pinched.
Harness protect sheet
attachment standard
Harness protect sheet
Harness protect sheet
attachment standard
4.Action:From the start of 1995 November production.
4.Measure to prevent the solenoid attachment plate from distorting.
1.Model name:SF-2025/2030/2040
2.General:When double sided copy operations are carried out continuously for a long period of
time under high temperatures, a rise in temperature occurs in the reversion solenoid
used in the rear frame, creating the danger of distortion or warping in the solenoid
attachment plate due to the heat. To alleviate this problem the solenoid has been
changed to one with a higher coil resistance, to maintain the temperature of the
solenoid at a lower degree.
3.Action:SF-2040 →From 1995 mid-October production.
SF-2025/2030 →From the start of 1995 November production.
3/4
Ref.
Model
No.
SF-2025
SF-2030
1
SF-2040
SF-2040
SF-2025
SF-2030
2
SF-2040
SF-2025
SF-2030
SF-2050
3
SF-2030
SF-2040
SF-2040
4
SF-2025
SF-2030
<Interchange>
1. Interchangeable.4. Not interchangeable.
2. C urr e nt t y pe c a n be u s ed i n p la ce of new t y pe .
New ty pe cann ot be us ed i n place of curr ent type .
3. C urre nt ty pe cann ot be used i n place of new ty pe.
New t y pe c a n be u sed in p la c e of c u rr en t ty p e.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
name
Version P/G No.
33 -44
33 -42VHDDSM1D1//-1
14 -45PCOVP1345FCZZPCOVP1345FCZ1 ARCover D
All
14 -15CBOX-0104FC01CBOX-0104FC02BABox D
12 -124 PSHEP4097FCZZDiscontinued—
12—PSHEP4097FCZ1 AC
9 -41
!
Current partsNew parts
Parts codeParts code
VHD1SS133//-1
—
RPLU-0307FCZZRPLU-0310FCZZARR solenoid
Price
5. Interchangeable if replaced with same types of
relate d parts in use .
6. Others .
Parts name
rank
AADiode
Harness protect
sheet
Harness protect
sheet N
Effec-
tive
time
1st lot
’96/2
Mid-
’95/10
Mid-
’95/11
Mid-
’95/10
Mid-
’95/11
1st lot
’95/11
Mid-
’95/10
1st lot
’95/11
Inter-
change-
ability
—
3
—
3
Note
Add
Q’ty
4/4
Loading...
+ hidden pages