Date: Aug. 8, 1995
COPIER : Z series
No. : SP-1905
1. REGARDING A CHANGE IN THE CL CONTROL PWB IC.
2. A PART CHANGE DUE TO DISCONTINUATION OF
PRODUCTION.
1. Regarding a change in the CL control PWB IC.
1.Model Name: Z-52/55/57/72/75/76/77/85/88, SF-2010 / 6100
2.General: In order to improve production, the IC used by the CL control PWB has been changed.
3.Description: Refer to the part code list for more detailed information.
4.Action: From the 1st unit of Jan., 1995 production.
2. A part change due to discontinuation of production.
1.Model Name: Z-52/57
2.General: Because the temperature fuse used in the copy lamp unit has been discontinued by the
manufacturer, another part will be substituted.
3.Description: As a result of the changes listed below, the temperature fuses setting will change from
139o to 142o .Furthermore, the display on lamp terminal base F will be set to 142o as well.
Temperature fuse 139
o
Lamp terminal base F 139
These parts are interchangeable.
o
Lamp terminal base F 142
Temperature fuse 142
o
o
4.Action: From the middle of Mar., 1995 production on. (running change)
SHARP CORPORATION Reprography Division
1/2
Green
C
Ref.
Model
No.
Z-52
Z-57
Z-85
Z-88
SF-2010
Z-55
1
Z-75
Z-72
SF-6100
Z-76
Z-77
Z-52
2
Z-57
<Interchange>
1. Interc ha ng ea bl e. 4. N ot i nt er ch an ge ab l e.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
speci fied ones fo r m ai n ta in i ng t he s a fe ty an d pe rformance o f the set .
name
Version P/G No.
12 -19
13 -19
14 -1
15 -1
All
16 -8
17 -8
3-4
3-6
!
Current parts New parts
Parts code Parts code
VHIMHIK-1//-2 VHISHN005//-1 AX IC (HIC 201)
CFS-T0073FC31 CFS-T0106FC32
LDAIU0269FCZZ LDAIU0269FCZ1
Price
5. Interchangeable if replaced with same types of
relate d parts in use .
6. Others.
Parts name
rank
Temperature
fuse
Lamp terminal
base f
Effec-
tive
time
1 st lot
’95/1
See
text
Inter-
change-
ability
1
5
Note
2/2