SHARP SP1904 Technical Report

Date: Aug. 21, 1995
COPIER : Z-20
No. : SP-1904
1.PERMANENT MEASURES FOR TROUBLESHOOTING WASHED-OUT COPIES.
1. Permanent measures for troubleshooting washed-out copies.
1.Model name: Z-20/25/27
2.General: Market action which was taken to alleviate an unfavorable market situation for our
company was reported in T/R No. SP-1885. The temporary and permanent measures designed for the production process, which are described below, have been carried out and are hereby reported.
Action
Date of object
Description
Marking
Market Action
For Machines produced before 1995 mid-March production.
1 Change in the copy resistance.
2 The main PWB volume (VR201) should be turned as far to the right as possible.
(Reproted in T/R No. SP-1885.)
None.
Temporary action
For machines produced between 1995 mid-March production and the end of 1995 May production.
1 The same as explained at left.
2 The same as explained at left.
3 The resistance of the main PWB (R785) had been change from 910 to 470.
The unit code printing area of the main PWB has been marked in red.
Change in the resistance of the main PWB.
Old New
R785 VRS-TS2AD911J VRS-TS2AD471J R720 VRS-TS2AD752J VRS-TS2AD622J
Permanent action
For manchines produced from 1995 June production.
1 The same as explained at left.
2 The volume of the main PWB has been set to 510µ during the production process.
3 The resistance of the main PWB (R785) has been changed from 910 to 470. Also, the resistor (R720) has been changed from 7.5k to
6.2k.
Change in the unit code of the main PWB.
SHARP CORPORATION Reprography Division
1/2
Green
C
Change in the unit code of the main PWB.
Old New
Z-20(110V) CPWBN1020FC51 CPWBN1020FC5A Z-20(120/127V) CPWBN1020FC55 CPWBN1020FC5E Z-20(220/240V) CPWBN1020FC52 CPWBN1020FC5B Z-25(110V) CPWBN1020FC53 CPWBN1020FC5C Z-25(120/127V) CPWBN1020FC56 CPWBN1020FC5F Z-25(220/240V) CPWBN1020FC54 CPWBN1020FC5D Z-27(110V) CPWBN1020FC57 CPWBN1020FC5G Z-27(120/127V) CPWBN1020FC58 CPWBN1020FC5H Z-27(220/240V) CPWBN1020FC59 CPWBN1020FC5I
Change in the unit code of the main PWB. Old. New. Note: The main PWB unit of the 100 V line has been established as service parts, but the main PWB of the 200 V line is scheduled to be changed in accordance with the CE mark standards, and therefore has not been established as service parts. A report of this matter will be sent separately.
4.Action: From the start of 1995 June production.
Ref.
Model
No.
Z-20 Z-25 Z-27
Z-20
1
Z-25
Z-27
<Interchange>
1. Interc ha ng ea bl e. 4. N ot i nt er ch an ge ab l e.
2. Current type can be used in place of new type. New type cannot be used in place of current type.
3. Current type cannot be used in place of new type. New type can be used in place of current type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
speci fied on es fo r m ai n ta in ing the sa fe ty an d pe r fo r ma nce o f the set .
name
Version P/G No.
10 -117 VRS-TS2AD911J VRS-TS2AD471J
All
10 105 VRS-TS2AD752J VRS-TS2AD622J Resistance[R720]
110V
series
120/127V
series
110V
series
120/127V
series
110V
series
120/127V
series
7 -18
10 -901
7 -18
10 -901
7 -18
10 -901
7 -18
10 -901
7 -18
10 -901
7 -18
10 -901
!
Current parts New parts
Parts code Parts code
CPWBN1020FC51 CPWBN1020FC5A
CPWBN1020FC55 CPWBN1020FC5E
CPWBN1020FC53 CPWBN1020FC5C
CPWBN1020FC56 CPWBN1020FC5F BT
CPWBN1020FC57 CPWBN1020FC5G BU
CPWBN1020FC58 CPWBN1020FC5H BS
Price
rank
AA
BS
5. Interchangeable if replaced with same types of relate d parts in use .
6. Others .
Parts name
Resistance[R785]
Main PWB
Effec-
tive
time
1st lot
’95/6
Inter-
change-
ability
3
Note