SHARP SP1871 Technical Report

Date: Mar. 31, 1995
COPIER : SF-2014
1. COUNTER ME AS U RE S FO R MANUAL FEE D AR M O P E RATI ON MAL FUNCTIONS IN THE
2. PREVENTION OF FOREIGN MATTER FROM ENTERING THE UPPER COVER OF THE SPF
3. COUNTER MEASURES FOR BLACK STREAKS WHICH OCCUR DURING REDUCTION COPY
1. Counter measures for manual feed arm operation malfunctions in the manual multi paper feed unit
1.Model name: SF-MF14 SN-MF1 1 (USA only)
No. : SP-1871
MANUAL MULTI PAPER FEED UNIT
(71%) OPERATIONS
2.General: The operations of the manual feed gate arm and the manual feed stopper sometimes did not run smoothly, due to the small size of the manual feed arm bushing in the manual multi paper feed unit. To alleviate this problem, the diameter of the bushing hole has been increased.
3.Description:
(Old) (New)
Bushing hold diameter
φ5 φ5.1
+ 0.1
-0
+ 0.15
- 0.05
Tem porary measure: Manual alterationPermanent measure: Change in metal mould
4. Action:
From the start of 1994 October productionFrom the start of 1995 February production