1. P ARTS CHANGES DUE TO DI SCONTINUANCE OF PRODUCTION
2. ADDITION OF RIB TO CASSETTE HANDLE
3. PREVENTION OF IRREGULAR NOISE FROM PAPER EXIT REVERSING UNIT SECTION
No. : SP-1864
1. Parts changes due to discontinuance of production
1.Model name: SF-2022, 2027, 2035, 1025, 8300, 8350, 8400, 7800, 7850, 7855
2.General: We have changed the temperature fuse in the copy lamp unit as follows. This was
because current fuse production was discontinued along with the change of the European standard.
3.Description: (Current) (New) Change of temperature fuse: 109°C 110°C Change of temperature display carved seal in the side plate F: 109°C 110°C
4.Action: From the first unit of December 1994 production
2. Addition of rib to cassette handle
1.Model name: SF-2022, 2027, 2035, 1025
2.General: When users pull out the
cassette to exchange or supply papers, they put their
Paper size display plate
fingers into the slit of the paper size display at the left side of the handle possibly and accidentally. Therefore, we have added rib to the size display plate to eliminate the slit.
Rib (added)