SHARP SP1848 Technical Report

Date: Feb. 24, 1995
COPIER : SF-2014
1. WIRE BAND CHANGE
2. ADDITION OF CONDITION LABEL PROTECTION SHEET
3. IMPROVEMENT OF WELDING PRESSURE OF MC SOCKET ELECTRODE A
4. ADDITION OF THE 6 TH MIRROR SCREW LOCK
No. : SP-1848
1. Wire band change
1.Model name: SF-2014, 2114, 2214
2.General: We have changed the manufacturer of the wire band and its part’s code due to the
production in China.
2. Addition of condition label protection sheet
1.Model name: SF-2214
2.General: During the transportation, the condition label
on the SPF was possible to be broken because the discharge paper tray hit it. Therefore we have added the protection sheet between the label and the discharge paper tray.
3.Action: From the first unit of mass production in 1994
Protection sheet
SHARP CORPORATION Reprography Division
1/3
Green
C
3. Improvement of welding pressure of MC socket electrode A
,
1.Model name: SF-2014, 2114, 2214
2.General: MC socket electrode was insufficiently welded with pressure to the MC in the socket
holder unit. It possibly caused the imperfect copying from MC output. We have added the socket electrode pressure plate to improve welding.
AAA
MC socket electrode A 14 -5
A
Socket electrode pressure plate
3.Action: From the first unit of mass production
4. Addition of the 6 th mirror screw lock
1.Model name: SF-2014, 2114, 2214
2.General: When the 6 th mirror was drawn to the
rear side, it possibly was detached from the eccentric screw. Therefore we have fixed the mirror by drawing to the front side and applying the screw lock after adjusting it. Apply one drop to the part A in the illustration shown at right.
V curved spring
The 6 th mirror 6 -40
Cross section A - A
A
Screw lock
Eccentric screw
3.Action: From mid-September 1994 production
2/3
Ref.
No.
Model
name
Version P/G No.
Current parts New parts
Parts code Parts code
Price
rank
Parts name
Effec-
tive
time
Inter-
change-
ability
Note
SF-2014
1
SF-2114 SF-2214
2 SF-2114 25 SPAKA1833FCZZ AC
SF-2014
3
SF-2114 SF-2214
<Interchange>
1. Interc ha ng ea bl e. 4. N ot i nt er ch an ge ab l e.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified on es fo r m ai n ta ini ng t he s a fe ty an d pe r fo rmance o f th e s et .
EX. only
New type cannot be used in place of current type.
New type can be used in place of current type.
17 -51
18 -36 LBNDJ2003SCZZ
All
14 LPLTM4879FCZZ AB
!
LBNDJ0013FCZZ
LBNDJ0013FCZ1 AA Wire band
RADF protection sheet
Socket electrode pressure plate
5. Interchangeable if replaced with same types of relate d parts in use .
6. Others .
1st lot ’94/10
1st lot
’94/9
1st lot
1
3/3