SHARP SP1817 Technical Report

Date: Sep. 29, 1994
COPIER : SF-8260
No. : SP-1817
DEALING WITH THE TROUBLE OF MAIN UNIT NOT TO BE ABLE TO TURN THE POWER ON
1.Model name: SF-8260
2.General: We found a trouble that the main unit could not be power on although its power switch
was turned on. Please take necessary measures shown in below to deal with troubles.
<Cause>
The soldering round surface of the ACN2 terminal of the connector with four pins (CN701) in the DC power PWB AC entering section was small. This caused cracks in soldering surface due to inserting connector or a long time heat stress. The terminal is opened under these conditions.
<Dealing with the trouble in the market>
Please take measures as follows when you provide maintenance or service. Remove the DC power PWB at first. Add jumper lead wire (0.8φ) between the connector with four pins (CN701) ACN2 terminal and diode terminal (D772) in the back side of PWB. Make sure the continuity between these terminals. (Please see the illustration below to refer the position to add.) Be careful to the jumper lead wire soldering not to contact other terminals.
Add soldering to the diode terminal (D772)
Detail of this part
ACN2 terminal
CN701 connector
Jumper lead wire
CN701 soldering surface
Add soldering to the ACN2 terminal
SHARP CORPORATION Reprography Division
1/2
Green
B-B
Ref.
No.
Model
name
Version P/G No.
Current parts New parts
Parts code Parts code
Price
rank
Parts name
Effec-
tive
time
Inter-
change-
ability
Note
SF-8260 All
<Interchange>
1. Interc ha ng ea bl e. 4. N ot i nt er ch an ge ab l e.
2. Current type can be used in place of new type. New type cannot be used in place of current type.
3. Current type cannot be used in place of new type. New type can be used in place of current type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
sp ec i fi e d on es fo r m ai n ta in i ng t he s a fe ty and per fo r ma nce o f the s et .
33
!
0CBFZZ0036ZZ/ AF Jumper lead wire
5. Interchangeable if replaced with same types of relate d parts in use .
6. Others .
2/2