SHARP SP1803 Technical Report

Date: Aug. 29, 1994
COPIER : Z-20
1. PERMANENT MEASURES TO PREVENT DROPOUT ON COPIES AND EDGE TRANSFER
2. PARTS CODE DESIGNATIONS FOR TONER CLUTCH SOLENOID AND POLYSLIDER
3. PARTS CHANGES DUE TO PRODUCTION DISCONTINUANCE
MISALIGNMENT ASSEMBLY PARTS
No. : SP-1803
1. Permanent measures to prevent dropout copies and edge transfer misalignment
1.Model name: Z-20, 25, 27
2.General: A DN mylar and DN holder spacer were mounted onto the DN holder unit, from the first
3.Description:
(Current)
(New)
A
A
1 2
Padding Padding
A'
A'
Padding
3
H1
"H1" marking
A-A
Padding
(Front)
A'-A'
(Back)
New DN holders have a “H1" marking to distinguish then from current holders.
SHARP CORPORATION Reprography Division
1/3
Green
C
4.Action: Mid-June 1994 production (Running change)
2. Parts code designations for toner clutch solenoid and polyslider assembly parts
1.Model name: Z-20, 23, 25, 27
2.General: A polyslider was added to the solenoid in the drive unit to prevent abnormal noises
during toner replenishment. The polyslider has now been assembled onto the solenoid and given a parts code designation.
3.Description: Current New Toner clutch solenoid (RPLU-0295FCZZ) Toner clutch solenoid (RPLU-0295FCZ1) With out polyslider With polyslider
New solenoids (with polyslider) and current solenoids (with polyslider mountings designated as service parts LX-WZ0186FCZZ) are interchangeable.
Polyslider
4.Action: Mid-June 1994 production
3. Parts changes due to production discontinuance
1.Model name: Z-20, 23, 25, 27
2.General: The photo coupler production used in the main PWB was discontinued. We have
changed it to alternates.
3.Description: The same photo coupler was used for all destinations. However, due to cost factors, separate parts have now been designated for the 100V and 200V series.
4.Action: July 1994 production, 1st unit.
2/3
Ref.
Model
No.
Z-20
1
Z-25 Z-27
2
Z-20 Z-23 Z-25 Z-27
3
<Interchange>
1. Interc ha ng ea bl e. 4. N ot i nt er ch an ge ab l e.
2. Current type can be used in place of new type. New type cannot be used in place of current type.
3. Current type cannot be used in place of new type. New type can be used in place of current type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
s p ec if ie d ones fo r m aintaini ng t he s a fe ty an d pe r fo rma nc e o f th e s et .
name
Version P/G No.
2-5
4 -10
All
10 -56 VHPPC112B//-1 VHPPC112L2/-1 AF Photo coupler 1
10 -56 VHPPC112B//-1 VHPPC112LY2-1 AF Photo coupler 1
!
Current parts New parts
Parts code Parts code
CHLDZ1169FC51 CHLDZ1169FC52 AN
RPLU-0295FCZZ RPLU-0295FCZ1 AM
Price
rank
5. Interchangeable if replaced with same types of relate d parts in use .
6. Others .
Parts name
Discharge holder unit
Toner clutch solenoid
Effec-
tive
time
Mid-
’94/6
(running
change
Mid-
’94/6
Inter-
change-
ability
1
41
Note
100V
series
200V
series
3/3