SHARP SP1770 Technical Report

Date: Jun. 27, 1994
COPIER : Z-88
1. IMPROVEMENT OF MARGIN ON THE CARRIER POWER
2. CHANGES TO THICKNESS OF FUSING LEVER FIXING PLATE TO IMPROVE PRODUCTIVITY
No. : SP-1770
1.Model name: Z-88, SF-2010
2.General: On rare occasions, jams caused by bugs were found to occur when using special paper
(OHP, labels, etc.). Changes have now been made to the parts for the paper supply unit. This is to improve the margin of the carrier power.
Discontinued # 9 , 16 ~ 20 Changed roller M1 (Note: Changed to one-way clutch type. Mount roller so that it rotates in the direction of the arrow.)
4.Action: SF-2010 : April 1994 production, 1st unit. Z-88 : Mid-March 1994 production.
SHARP CORPORATION Reprography Division
1/3
Green
C
2. Changes to the thickness of fusing lever fixing plate to improve productivity
1.Model name: Z-88, SF-2010
2.General: Changes have been made to thickness of the fusing lever fixing plate in the upper
frame F unit. This is to improve productivity. In accordance with the these changes, the fusing fixing spacer has been discontinued.
3.Description:
(Current) (New)
Fusing lever fixing plate (t1.0)
Spacer
Current and new upper frame F units are interchangeable. Parts code remain unchanged.
4.Action: May 1994 production, 1st unit .
Fusing lever fixing plate II (t1.6)
Printing
2/3
Loading...