SHARP SP1762 Technical Report

Date: May. 25, 1994
COPIER : Z-72
1. CHANGE TO RELAY AS TERMINAT I ON OF PRODUCTION HAS BEEN CARRIED OUT
2. IMPROVE MEN T OF D EL IVE RY JAMS
1. Change to relay as termination of production has been carried out
1.Model name: Z-72/77 SF-6100
2.General: Change the relay (G5R5-A) used in PWB unit to substitutional products because
termination of production has been carried out. Before change has been carried out, same type of the relay was used in both 100V series and 200V series. To meet safety standard specifications, relays newly have been laid each 100V series and 200V series. <100V Series relay PWB>
CPWBF0856FC51~55, 63~65, 72~75, 82~85
No. : SP-1762
<200V Series relay PWB>
CPWBF0856FC57~58, 67, 68, 77, 78, 87, 88
3.Description: Current (100V/200V) New (100V) G2R-1A RRLYD4121QCZZ
(G5R5-A) RRLYD3121QCZZ (200V)
G2R-1A4-SKVD RRLYD3128QCZZ
4.Action: From mid-April 1994 production.
2. Improvement of delivery jams
1.Model name: Z-52/52II//57/57II/72/77/88/55 SF-2010/6100
2.General: Motor base plate has been added to hold the lever of delevery switch actuator to deal
with jams when actuator recovering is in trouble.
SHARP CORPORATION Reprography Division
1/2
Green
C
3.Description:
,
A: Detailed illustration-position of attaching
Motor cover
A
4.Action: From the first unit of April 1994 production.
0.5
0.5
0
0
Motor base plate mylar
• The standard attaching position of motor base plate mylar to MS-2 (Delivery switch) notch hall is referred to left illustration.
<Attention>
• Degrease the motor base plate mylar attaching position by using alcohol.
• Avoid disengagement or loosing of motor base plate mylar.
Ref.
Model
No.
Z-72 SF-6100
1
Z-77
Z-52 Z-52II Z-57 Z-57II Z-72 Z-77
2
Z-88 Z-55 SF-6100
SF-2010
<Interchange>
1. Intercha ng ea bl e. 4. N ot i nt er ch an ge ab l e.
2. Current type can be used in place of new type. New type cannot be used in place of current type.
3. Current type cannot be used in place of new type. New type can be used in place of current type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified on es for m ai n ta in ing the sa fe ty an d pe r fo rma nc e o f the set .
name
Version P/G No.
100V
14 -8 RRLYD3121QCZZ RRLYD4121QCZZ AN Relay
series
200V
14 -8 RRLYD3121QCZZ RRLYD3128QCZZ AQ Relay
series
100V
15 -8 RRLYD3121QCZZ RRLYD4121QCZZ AN Relay
series
6
All
7
!
Current parts New parts
Parts code Parts code
PSHEP3668FCZZ AB
PSHEP3668FCZZ AB
5. Interchangeable if replaced with same types of
6. Others .
Price
relate d parts in use .
Parts name
rank
Motor base plate mylar
Motor base plate mylar
Effec-
tive
time
Mid-
’94/4
Mid-
’94/4
Mid-
’94/4
See text.
See text.
Inter-
change-
ability
1
1
1
Note
2/2
Loading...