SHARP SP1754 Technical Report

Date: May. 18, 1994
COPIER : Z-52
No. : SP-1754
TROUBLE SHOOTING DISLOCATION OF THE FEEDER SWITCH.
1.Model name: Z-52, 52 II, 57, 57 II
2.General: Contact is sometimes made with the fixing teeth of the feeder switch (MS 1-3) when
installing the right side of the cabinet, causing the feeder switch to become dislocated. To prevent this problem from occurring, “Screw Lock” has been added.
3.Description:
Applied "Screw lock"
<“Screw Lock” to be used>
Three Pound 1401 B YRESNHMP007CC (ap pr ox 0. 1g) Sumitomo 3M
4.Action: From 1994 April production.
MS1-3
PG-C
<Caution>
When applying “Screw Lock” care should be exercised so that the “Screw Lock” does not come in contact with any of the other parts.
SHARP CORPORATION Reprography Division