SHARP SP1685W Technical Report

Figure
avail-
Discription
Effec-
tive
Inter-
change-
ability
time
X
Fig. 1
The frame connection plate unit area has been
changed to improve productivity.
The MS 1 spring has been changed to trouble
shoot the return misses of the MS 1 actuator.
B 5 ’93/4
X
X
In accordance with the wishes of OEM, the
label has been changed such that it is written in
The parts code reported in T/R SP-1537 has
been changed back to the original code.
3 languages.
H 1 ’93/10
X
In accordance with the wishes of OEM, the
label has been changed such that it is written in
3 languages.
X
The acuride has been changed to improve
H 1 ’93/7
X
The AC cord has been changed in accordance
with the change in terminal connector
productivity.
compatibility standards.
1 H ’93/1
Parts name Cause
Price
rank
PLNS-0046FCZZ BL SLA
LHLDZ1110FCZZ AC Lens holder.
4 -17 PLNS-0037FCZZ
4 -29 PSHEP2191FCZZ PSHEP2191FCZ1 AD SLA mylar A.
LFIX-0330FCZZ AA SLA holder.
4 -22 PSHEP2192FCZZ PSHEP2192FCZ1 AD SLA mylar B.
4 -9 LFIX-0330FCZZ
SLA holder N.
LFIX-0449FCZZ AA
PSHEP2364FCZZ AA AE sheet.
4
Reinforcement reflector
sheet.
Reinforcement reflector
4 -8 PSHEP2028FCZZ PSHEP3181FCZZ AH MC mylar.
4 PSHEZ3152FCZZ AC
4 -4 PSHEP2166FCZZ PSHEP3194FCZZ AC
sheet R.
14 -8 UCLEZ0087FCZZ UCLEZ0087FCZ1 AG Charger cleaner.
10 -51 MSPRC1458FCZZ MSPRC1458FCZ1 AB MS 1 spring. A 3 ’93/3
Service and maintenance
warning label.
AD
TCAUH0976FCZZ
MSLI-0112FCZZ MSLI-0082FCZZ AA TG slider. B 1 ’93/9
All
5 -10
1 -32 TCAUH0916FCZZ
1 TCAUH0973FCZZ
Service and maintenance
warning label.
11 -28 TCAUH0910FCZZ TCAUH0950FCZZ AD User warning label B.
1 -32 TCAUH0916FCZZ TCAUH0973FCZZ AC
11 -19 TCAUH0911FCZZ TCAUH0949FCZZ AD User warning label A.
AC cord (for export models
bound for SEEG).
MSLI-0083FCZ1 MSLI-0083FCZ2 AU Acuride. B 1 ’93\3
SEEG
3-7
14 -9 QACCV6620QCN1 QACCV6621QCN1 AU
!
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type. New type cannot be used in place of current type. 5. Interchangeable if replaced with same types of related parts in use.
3. Current type cannot be used in place of new type. New type can be used in place of current type. 6. Others.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
2/3
Ref.
Model name Subject P/G No. Version Current New
No.
Change in the frame
connection plate unit area.
1
Z30
2 Change in MS 1 spring.
3 Change in TG slider.
Change in AC cord (for
export models bound for
SEEG).
4 Change in acuride.
5
A : Quality improvement
B : Productivity improvement
C : Operability improvement
D : Convenience of parts procurement
E : Standardization
F : Serviceability improvement
Reason for cause
G : Correction to parts guide
Loading...