SHARP SP1670W Technical Report

Figure
avail-
Discription
ability
X
Fig. 1
Two fan duct molts have been added to
alleviate the problem of abnormal noise
caused by contact between the ventilation fan
X
and the fan duct.
The ferrite core reported in T/R SP-1581 has
been eliminated.
Fig. 2
block has been added to prevent the optical
wire from becoming dislocated
Fig. 3
A cushion has been added so that the
transistor and the harness do not come in
close proximity. This measure is designed to
prevent errors caused by noise emitted by the
transistor
Effec-
tive
Inter-
change-
Parts name Cause
Price
time
rank
first unit
From the
mass
produced
1992
Mid-Dec.
2/3
Ref.
Model name Subject P/G No. Version Current New
No.
14 -11 All VHPLB403MF1-1 VHPLB403MP1// AR Photo transistor G 1
Change in LED on the
operation circuit board.
Z-88
SF-2010
1
6 PMLT-0927FCZZ AA Fan duct molt A ’93/7
Addition of a fan duct molt
Z-88
SF-2010
2
LDAIU0479FCZZ AG Wire block A
RCORF0012FCZZ Eliminated Ferrite core B ’93/8
only
100V
series
12
The ferrite core has been
eliminated from the 100V
series.
Z-88
SF-2010
3
ALL
5
Addition of a wire block to the
optical unit
Z-88
SF-2010
4
<Interchange>
1. Interchangeable. 4. Not interchangeable.
7 PCUSF0280FCZZ AB High voltage cushion A ’93/2
Addition of a cushion to the
high voltage circuit board.
Z-88
SF-2010
A : Quality improvement
B : Productivity improvement
5
C : Operability improvement
Reason for cause
!
2. Current type can be used in place of new type. New type cannot be used in place of current type. 5. Interchangeable if replaced with same types of related parts in use.
3. Current type cannot be used in place of new type. New type can be used in place of current type. 6. Others.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
D : Convenience of parts procurement
E : Standardization
F : Serviceability improvement
G : Correction to parts guide
Loading...