SHARP SP1670 Technical Report

Date: Jan. 25, 1994
COPIER : Z-88
No. : SP-1670
CHANGE IN PARTS (Z-88 / SF-2010).
1.General: Var ious parts changes have been carried out on models Z-88 and SF-2010.
2.Description: 1.Change in LED on the operation circuit board.
2.Addition of a fan duct molt.
3.The ferrite core has been eliminated from the 100 V series.
4.Addition of a wire block to the optical unit.
5.Addition of a cushion to the high voltage circuit board.
1/3
Green
C
2/3
Ref.
Model name Subject P/G No. Version Current New
No.
1
2
3
4
5
Z-88 SF-2010
Z-88 SF-2010
Z-88 SF-2010
Z-88 SF-2010
Z-88 SF-2010
Change in LED on the operation circuit board.
Addition of a fan duct molt
The ferrite core has been eliminated from the 100V series.
Addition of a wire block to the optical unit
Addition of a cushion to the high voltage circuit board.
14 -11 All VHPLB403MF1-1 VHPLB403MP1// AR Photo transistor G 1
6 PMLT-0927FCZZ AA Fan duct molt A ’93/7
100V
12
series
RCORF0012FCZZ Eliminated Ferrite core B ’93/8
only
5
LDAIU0479FCZZ AG Wire block A
ALL
7 PCUSF0280FCZZ AB High voltage cushion A ’93/2
Price
rank
Parts name Cause
Inter-
change-
ability
Effec­tive
Discription
time
From the
first unit
mass
produced
Two fan duct molts have been added to alleviate the problem of abnormal noise caused by contact between the ventilation fan and the fan duct.
The ferrite core reported in T/R SP-1581 has been eliminated.
Mid-Dec.
block has been added to prevent the optical
1992
wire from becoming dislocated A cushion has been added so that the
transistor and the harness do not come in close proximity. This measure is designed to prevent errors caused by noise emitted by the transistor
Figure avail­ability
X
Fig. 1
X
Fig. 2
Fig. 3
Reason for cause
A : Quality improvement B : Productivity improvement C : Operability improvement D : Convenience of parts procurement E : Standardization F : Serviceability improvement G : Correction to parts guide
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type. New type cannot be used in place of current type. 5. Interchangeable if replaced with same types of related parts in use.
3. Current type cannot be used in place of new type. New type can be used in place of current type. 6. Others. Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
!
Loading...