SHARP SP1624 Technical Report

Date: Sep. 14, 1993
COPIER : SF-2035
1. OPERATIONAL IMPROVEMENT BY CHANGING THE WASTE TONER BOX RELEASE LEVER AND PLATE THICKNESS
2. AVOIDING THE HARNESS FROM CAUGHT UP WHEN REMOVING AND INSTALLING THE DRUM CLEANER UNIT
No. : SP-1624
1. Operational improvement by changing the waste toner box release lever and plate thickness
1.Model name: SF-2022 / 2027 / 2035
2.General: The thickness of the lever is changed to eliminate the freedom of the waste toner box
3.Reason: This is to improve the movement of the waste toner box release lever.
4.Description: The thickness of the waste toner box release lever is changed from 1.0 to 1.2 thick.
Waste toner box release lever: Changed MLEVF0610FCZZ MLEVF0610FCZ1
5.Action: (Factory action) Since July 1993.
SHARP CORPORATION Reprography Division
1/4
Green
C
2. Avoiding the harness from caught up when removing and installing the drum cleaner unit
1.Model name: SF-2035 / 2027 / 2022
2.General: Change is made to the structure of the upper drum frame and the MC duct A to avoid
possible seizure of the harness when removing or installing the drum clear unit from the copier. This change is also applied to SF-2022 and SF-2027 allow the shared use.
3.Reason: This is to prevent the seizure of the harness when removing or installing the drum cleaner unit.
4.Description: 1. Drum cleaner unit structural change (running change since June 1993).
The size of the area where the harness goes through is changed from 3mm to 5.5mm (deeper indent).
Changed current 3mm to new 5.5mm.
LFRM-0733FCZ1 LFRM-0733FCZ2
A mark “B” is printed on the new item.
Running change since June 1993.
2. MC duct A structural change
a. A rib is added (two locations), running change since mid-April 1993. b. Addition of stud, running change since June 1993.
a. Addition of rib
Rib added
Rib added
2/4
Parts code is reassigned to the MC duct A after the addition of rib. PDUC-0063FCZZ PDUC-0063FCZ1
Factory action: Running change since mid-April 1993.
b. Addition of stud
B
Stud added
A “B” is stamped on the new item.
The parts code is reassigned to the MC duct A after the addition of stud. PDUC-0063FCZ1 PDUC-0063FCZ2
Factory action: Running change since mid-June 1993.
To provide the tolerance to avoid the seizure of the harness, the BL harness lamp bracket (LPLTP4531FCZZ) will be employed from September 1993. A harness sheet had been used since mid-April 1993 as a makeshift action.
4x8P tight (XEPSD40P08000)(added)
Blank lamp clamp bracket (added) (LPLTP4531FCZZ)
MC duct A (PDUC-0063FCZ2) Upper drum frame (LFRM-0733FCZ2)
Blank lamp harness
Makeshift action: Use of the harness sheet (since April 1993)
(Must be pasted)
Harness sheet (PSHEP3544FCZZ)
Baseline
Paste the mylar over the drum harness as if covering from above. For the mylar comes swelling, try to hold down the mylar when pasting. After this, use the wiring tie to fasten.
NOTE: Only the blank harness clamp bracket can be added to the MC duct A with
the new stud (PDUC-0063FCZ2).