Date: Apr. 1, 1994
DUPLICATOR: SD-3062
CHANGE IN AC CIRCUIT PWB OF MACHINES BOUND
FOR THE UNITED STATES AND CANADA TO IMPROVE
PRODUCTIVITY.
1.Model name: SD-2060 / 3062
2.General: The AC circuit PWB boards of machines bound for the United States and Canada have
been changed for the reasons described below.
No. : S-142
3.Cause: To improve productivity.
4.Description: The unit code of the AC circuit PWB of machines bound for the United States and
Canada have been changed in accordance with the c hanges and eliminations of the
parts listed below.
5.Action: (Factory action)
From 1994 April production.
Note: The parts guide numbers given on the top rows in the list of changed parts are for
model SD-2060, and those given on the bottom rows are for model SD-3062.
SHARP CORPORATION Reprography Division
1/2
Green
C
Ref.
No.
Model
name
Version
P/G No.
*
Current parts New parts
Parts code Parts code
Price
rank
Parts name
Effec-
tive
time
Inter-
change-
ability
Note
52 -7
83 -7
52 -18
83 -18
52 -22
SD-2060
SD-3062
<Interchange>
1. Interc ha ng ea bl e. 4. N ot i nt er ch an ge ab l e.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specifi e d on es fo r m ai n ta in i ng t he safety an d pe r fo rma nc e o f the set .
USA
Canada
83 -22
52 -30
83 -30
42 -1
52 -901
42 -1
83 -901
!
QCNCW0857FCZZ — — Connector — CN5
RMPTA0030FCZZ — — CR mix part —
RRLYD4220QCZZ — — Relay — RY301
VHRS21ME4FY-1 VHRS21ME4Y/1 AH Photo thyristor 1
CPWBF0988FC51 CPWBF0988FC52 BR AC circuit PWB 1
5. Interchangeable if replaced with same types of
relate d parts in use .
6. Others .
CR301
305
SSR302
303
2/2