SHARP R510C2, R-508CK, R-510CK, R-510CW Service Manual

0 (0)
SER VICE MANU AL
S3906R510CPW/
MICROWAVE OVEN
R-508CK R-510CK R-510CW
COOK
DEFOST
MINUTE PLUS
INSTANT ACTION
TO ADJUST QUANTITY - TOUCH PAD AGAIN
Dinner
Casserole
Plate
Baked
Beverage
Potatoes
Frozen
Frozen
Entress
Vegetables
1Ground Meat 2Steaks/Chops 3Chicken Pieces
COMPU DEFROST
123 456 78
Power
0
Level
Stop
START
Clear
MODELS
NO. LBS. CUPS.
OZ.
Popcorn
Fresh Vegetables
Rolls/
Muffins
9
Timer
Clock
R-508CK R-510CK R-510CW
In the interest of user-safety the oven should be restored to its original
R-508CK
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con­tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Recti­fier Assembly, High Voltage Harness etc..)
TABLE OF CONTENTS
Page PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO
AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY...................INSIDE FRONT COVER
BEFORE SERVICING ......................................................................................................INSIDE FRONT COVER
WARNING TO SERVICE PERSONNEL................................................................................................................ 1
MICROWAVE MEASUREMENT PROCEDURE ...................................................................................................2
FOREWORD AND WARNING...............................................................................................................................3
PRODUCT SPECIFICATIONS ..............................................................................................................................4
GENERAL INFORMATION...................................................................................................................................4
OPERATION..........................................................................................................................................................6
TROUBLESHOOTING GUIDE ..............................................................................................................................9
TEST PROCEDURE............................................................................................................................................10
TOUCH CONTROL PANEL .................................................................................................................................18
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE ................................................................22
PICTORIAL DIAGRAM ........................................................................................................................................28
POWER UNIT CIRCUIT ......................................................................................................................................29
LSI UNIT CIRCUIT...............................................................................................................................................30
PRINTED WIRING BOARD .................................................................................................................................32
PARTS LIST ........................................................................................................................................................33
PACKING AND ACCESSORIES .........................................................................................................................37
SHARP CORPORATION
This document has been published to be used for after sales service only. The contents are subject to change without notice.
R-508CK R-510CK R-510CW
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave
generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.
BEFORE SERVICING
Before servicing an operative unit, perform a microwave emission check as per the Microwave Measurement Procedure outlined in this service manual. If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS CORPORATION immediately @1-800-237-4277.
If the unit operates with the door open, service person should 1) tell the user not to operate the oven and 2) contact SHARP ELECTRONICS CORPORATION and Food and Drug Administration's Center for Devices and Radiological Health immediately.
Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit found with emissions in excess of 4mW/cm2. The owner of the unit should be instructed not to use the unit until the oven has been brought into compliance.
NO. LBS.
CUPS.
OZ.
COOK
DEFOST
MINUTE PLUS
BEVERAGE
POPCORN
INSTANT ACTION
TO ADJUST QUANTITY - TOUCH PAD AGAIN
inner
D
olls/
R
asserole
C
plate
muffins
aked
B
resh
F
round
G
potatoes
vegetables
meat
rozen
F
rozen
icrowave
F
M
entrees
vegetables
pizza
1Ground Meat 2Steaks/Chops
COMPU DEFROST
3Chicken Pieces
123 456 78
9
Power
Timer
0
Level
Clock
Stop
START
Clear
R-510CK/CW
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro­ducing very high voltage and current, contact with following parts fatal, electrical shock.
(Example) High Voltage Capacitor, High Voltage Power Trans-
former, Magnetron, High Voltage Rectifier Assem­bly, High Voltage Harness etc..
Read the Service Manual carefully and follow all instructions.
may result in a severe, possibly
Don't Touch ! Danger High Voltage
R-508CK R-510CK R-510CW
Before Servicing
1. Disconnect the power supply cord , and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
WARNING:RISK OF ELECTRIC SHOCK.
DISCHARGE THE HIGH-VOLTAGE CAPACITOR BEFORE SERVICING.
The high-voltage capacitor remains charged about 60 seconds after the oven has been switched off. Wait for 60 seconds and then short-circuit the connection of the high­voltage capacitor (that is the connecting lead of the high­voltage rectifier) against the chassis with the use of an insulated screwdriver.
Whenever troubleshooting is performed the power supply must be disconnected. It may in, some cases, be necessary to connect the power supply after the outer case has been removed, in this event,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.
6. After that procedure, reconnect the power supply cord.
When the testing is completed,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Reconnect the leads to the primary of the power transformer.
5. Reinstall the outer case (cabinet).
6. Reconnect the power supply cord after the outer case is installed.
7. Run the oven and check all functions.
After repairing
1. Reconnect all leads removed from components during testing.
2. Reinstall the outer case (cabinet).
3. Reconnect the power supply cord after the outer case is installed.
4. Run the oven and check all functions.
Microwave ovens should not be run empty. To test for the presence of microwave energy within a cavity, place a cup of cold water on the oven turntable, close the door and set the power to HIGH and set the microwave timer for two (2) minutes. When the two minutes has elapsed (timer at zero) carefully check that the water is now hot. If the water remains cold carry out Before Servicing procedure and re­examine the connections to the component being tested.
When all service work is completed and the oven is fully assembled, the microwave power output should be checked and a microwave leakage test should be carried out.
1
R-508CK R-510CK R-510CW
MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven.
2) Safety interlock switches Primary interlock relay and door sensing switch shall prevent microwave radiation emission in excess of the requirement as above mentioned, secondary interlock switch shall prevent microwave radiation emission in excess of 5 mW/cm2 at any point 5cm or more from the external surface of the oven.
B. Preparation for testing: Before beginning the actual measurement of leakage, proceed as follows:
1) Make sure that the actual instrument is operating normally as specified in its instruction booklet.
Important: Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for microwave ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.
2) Place the oven tray in the oven cavity.
3) Place the load of 275±15 ml (9.8 oz) of tap water initially at 20±5˚C (68˚F) in the center of the oven cavity. The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-1/2 in.) and made of an electrically nonconductive material such as glass or plastic. The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage is measured accurately.
4) Set the cooking control on Full Power Cooking Mode.
5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed, replace it with 275 ml of cool water.
C. Leakage test:
Closed-door leakage test (microwave measurement)
1) Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven.
2) Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on the meter.
3) Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity of the metal has been breached (eg., around the switches, indicator, and vents). While testing for leakage around the door pull the door away from the front of the oven as far as is permitted by the closed latch assembly.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm2, and that the secondary interlock switch does turn the oven OFF before any door movement.
NOTE: After servicing, record data on service invoice and microwave leakage report.
2
SERVICE MANUAL
R-508CK R-510CK R-510CW
MICROWAVE OVEN
R-508CK/ R-510CK/ R-510CW
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVEN, R-508CK, R-510CK, R-510CW.
It is recommended that service personnel carefully study the entire text of this manual so that they will be qualified to render satisfactory customer service.
Check the interlock switches and the door seal carefully. Special atten­tion should be given to avoid electrical shock and microwave radiation hazard.
WARNING
Never operate the oven until the following points are ensured. (A) The door is tightly closed. (B) The door brackets and hinges are not defective. (C) The door packing is not damaged. (D) The door is not deformed or warped. (E) There is no other visible damage with the oven.
Servicing and repair work must be carried out only by trained service personnel.
DANGER
Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing. Service person­nel - Do not contact the following parts while the appliance is energized; High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness; If provided, Vent Hood, Fan assembly, Cooling Fan Motor.
PRODUCT DESCRIPTION
GENERAL INFORMATION
OPERATION
TROUBLESHOOTING GUIDE AND TEST PROCEDURE
TOUCH CONTROL PANEL
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
WIRING DIAGRAM
PARTS LIST
All the parts marked “*” on parts list are used at voltages more than 250V.
Removal of the outer wrap gives access to voltage above 250V. All the parts marked “” on parts list may cause undue microwave
exposure, by themselves, or when they are damaged, loosened or removed.
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
3
R-508CK R-510CK R-510CW
SPECIFICATION
ITEM DESCRIPTION
Power Requirements 120 Volts / 13 Amperes
60 Hertz Single phase, 3 wire grounded
Power Output 1100 watts (IEC-705 TEST PROCEDURE)
Operating frequency of 2450MHz
Case Dimensions Width 24"
Height 13-3/8" Depth 19-1/8"
Cooking Cavity Dimensions Width 17-3/8"
Height 10-1/2"
2.0 Cubic Feet Depth 18-5/8" Control Complement Touch Control System
Clock ( 1:00 - 12:59 ) Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable Cooking Repetition Rate;
P-HI.................................................. Full power throughout the cooking time
P-90 .................................................................... approx. 90% of Full Power
P-80 .................................................................... approx. 80% of Full Power
P-70 .................................................................... approx. 70% of Full Power
P-60 .................................................................... approx. 60% of Full Power
P-50 .................................................................... approx. 50% of Full Power
P-40 .................................................................... approx. 40% of Full Power
P-30 .................................................................... approx. 30% of Full Power
P-20 .................................................................... approx. 20% of Full Power
P-10 .................................................................... approx. 10% of Full Power
P-0 .................................................... No power throughout the cooking time BEVERAGE pad (R-510CK/W only), POPCORN pad (R-510CK/W only)
MINUTE PLUS pad, INSTANT ACTION pads COMPU DEFROST pads, Number selection pads Power Level pad, Timer/Clock pad Stop/Clear pad, START pad
Oven Cavity Light Yes Safety Standard UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements The electrical requirements are a 120 volt 60 Hz, AC only, 15 or 20 amp. fused electrical supply. It is recommended that a separate circuit serving only this appliance be provided. When installing this appliance, observe all applicable codes and ordinances. A short power-supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord. Where a two-pronged wall-receptacle is encountered, it is the personal responsibility and obligation of the customer to
4
contact a qualified electrician and have it replaced with a properly
3-Pronged Plug
Grounded Receptacle Box
Grounding Pin
3-Pronged Receptacle
grounded three-pronged wall receptacle or have a grounding adapter properly grounded and polarized. If the extension cord must be used, it should be a 3-wire, 15 amp. or higher rated cord. Do not drape over a countertop or table where it can be pulled on by children or tripped over accidentally.
CAUTION: DO NOT UNDER ANY CIRCUMSTANCES CUT OR RE-
MOVE THE ROUND GROUNDING PRONG FROM THIS PLUG.
OVEN DIAGRAM
1. One touch door open button. Push to open door.
2. Door latches. The oven will not operate unless the door is securely closed.
3. Removable turntable support.
4. Removable turntable. The turntable will rotate clockwise or counterclockwise.
5. Oven lamp. It will light when oven is operating or door is opened.
6. Oven door with see-through window.
7. Ventilation openings. (Rear)
8. Auto-Touch control panel.
9. Time display: Digital display, 99 minutes 99 seconds.
10. Coupling.
11. Wave guide cover.
12. Power supply cord
6
2
10
3
TOUCH CONTROL PANEL
11
R-508CK R-510CK R-510CW
5
4
7
12
9
8
1
INSTANT ACTION
TO ADJUST QUANTITY - TOUCH PAD AGAIN
Dinner
Plate
Baked
Potatoes
Frozen
Entress
1 Ground Meat 2 Steaks/Chops 3 Chicken Pieces
123 456 78
Power
Level
COOK
Stop Clear
DEFOST
Casserole
Beverage
Frozen
Vegetables
NO.
LBS.
CUPS.
OZ.
MINUTE PLUS
Popcorn
Fresh
Vegetables
Rolls/
Muffins
COMPU DEFROST
9
0
Timer Clock
START
NO.
LBS.
CUPS.
DEFOST
COOK
POPCORN
D
B
F
entrees
1 Ground Meat 2 Steaks/Chops 3 Chicken Pieces
BEVERAGE
INSTANT ACTION
TO ADJUST QUANTITY - TOUCH PAD AGAIN
inner
plate
aked
potatoes
rozen
asserole
C
resh
F
vegetables
rozen
F
vegetables
OZ.
MINUTE PLUS
olls/
R
muffins
round
G
meat
icrowave
M
pizza
COMPU DEFROST
123 456 78
Power
Level
0
Stop
Clear
9
Timer Clock
START
R-508CK R-510CK/CW
5
R-508CK R-510CK R-510CW
OPERATION
DESCRIPTION OF OPERATING SEQUENCE
The following is a description of component functions during oven operation.
OFF CONDITION
Closing the door activates the door sensing switch and secondary interlock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1).
1. The display will show flashing "88:88". To set any program or set the clock, you must first touch the STOP/CLEAR pad. The display will clear, and " : " will appear.
COOKING CONDITION
Program desired cooking time by touching the NUMBER pads. Program the power level by touching the POWER LEVEL pad and then a Number pad. When the START pad is touched, the following operations occur:
1. The contacts of relays are closed and components connected to the relays are turned on as follows. (For details, refer to Figure O-2)
relay and is mechanically associated with the door so that it will function in the following sequence.
(1) When the door opens from the closed position, the
primary interlock relay (RY2) and secondary interlock switch open their contacts. And contacts of the relay (RY1) remains closed. Then the monitor switch contacts close.
(2) When the door is closed from the open position, the
monitor switch contacts open first. Then the contacts of the secondary interlock switch and door sensing switch
close. And contacts of the relay (RY1) open. If the secondary interlock switch and primary interlock relay (RY2) fail with the contacts closed when the door is opened, the closing of the monitor switch contacts will form a short circuit through the monitor fuse, secondary interlock switch, relay (RY1) and primary interlock relay (RY2), causing the monitor fuse to blow.
POWER LEVEL P-0 TO P-90 COOKING
When Variable Cooking Power is programmed, the 120 volts A.C. is supplied to the power transformer intermittently through the contacts of relay (RY-2) which is operated by the control unit within a 32 second time base. Microwave power operation is as follows:
RELAY CONNECTED COMPONENTS RY-1 oven lamp/turntable motor/fan motor RY-2 power transformer
2. 120 volts A.C. is supplied to the primary winding of the power transformer and is converted to about 3.3 volts A.C. output on the filament winding, and approximately 2370 volts A.C. on the high voltage winding.
3. The filament winding voltage heats the magnetron filament and the H.V. winding voltage is sent to a voltage doubler circuit.
4. The microwave energy produced by the magnetron is channelled through the waveguide into the cavity feed­box, and then into the cavity where the food is placed to be cooked.
5. Upon completion of the cooking time, the power transformer, oven lamp, etc. are turned off, and the generation of microwave energy is stopped. The oven will revert to the OFF condition.
6. When the door is opened during a cook cycle, the monitor switch, door sensing switch, secondary interlock switch, relay (RY1) and primary interlock relay are activated with the following results. The circuits to the turntable motor, the cooling fan motor, and the high voltage components are de-energized, the oven lamp remains on, and the digital read-out displays the time still remaining in the cook cycle when the door was opened.
7. The monitor switch electrically monitors the operation of the secondary interlock switch and primary interlock
VARI-MODE ON TIME OFF TIME Power 10(P-HI) 32 sec. 0 sec.
(100% power) Power 9(P-90) 30 sec. 2 sec.
(approx. 90% power) Power 8(P-80) 26 sec. 6 sec.
(approx. 80% power) Power 7(P-70) 24 sec. 8 sec.
(approx. 70% power) Power 6(P-60) 22 sec. 10 sec.
(approx. 60% power) Power 5(P-50) 18 sec. 14 sec.
(approx. 50% power) Power 4(P-40) 16 sec. 16 sec.
(approx. 40% power) Power 3(P-30) 12 sec. 20 sec.
(approx. 30% power) Power 2(P-20) 8 sec. 24 sec.
(approx. 20% power) Power 1(P-10) 6 sec. 26 sec.
(approx. 10% power) Power 0(P-0) 0 sec. 32 sec.
(0% power)
Note: The ON/OFF time ratio does not correspond with
the percentage of microwave power, because approx. 2 seconds are needed for heating of the magnetron filament.
6
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED.
2. CLOCK APPEARS ON DISPLAY.
NOTE: Indicates components with potential above 250 V.
R-508CK R-510CK R-510CW
120V AC 60 Hz
MAGNETRON TEMP.  FUSE
GRN
CAVITY TEMP.  FUSE
MONITOR  FUSE 20A
A2
A1
CONTROL UNIT
OL FM
OVEN LAMP
SECONDARY INTERLOCK SWITCH
(RY-1)
TTM
Figure O-1. Oven Schematic-Off Condition
TURN- TABLE MOTOR
COM.
FAN  MOTOR
N.O.
COM.N.O.
B1 B2
(RY-2)
PRIMARY INTERLOCK RELAY
DOOR SENSING SWITCH
N.C.
COM.
MONITOR  SWITCH
CAPACITOR 1.0µF AC 2300V
POWER  TRANSFORMER
H.V. RECTIFIER
MAGNETRON
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED.
2. COOKING TIME PROGRAMMED.
3. VARIABLE COOKING CONTROL "HIGH".
4. "START" PAD TOUCHED.
120V AC 60 Hz
MAGNETRON TEMP.  FUSE
GRN
CAVITY TEMP.  FUSE
MONITOR  FUSE 20A
A2
A1
CONTROL UNIT
OL FM
OVEN LAMP
SECONDARY INTERLOCK SWITCH
(RY-1)
TTM
TURN- TABLE MOTOR
COM.
FAN  MOTOR
N.O.
COM.N.O.
B1 B2
(RY-2)
PRIMARY INTERLOCK RELAY
DOOR SENSING SWITCH
N.C.
COM.
MONITOR  SWITCH
CAPACITOR 1.0µF AC 2300V
POWER  TRANSFORMER
H.V. RECTIFIER
MAGNETRON
Figure O-2. Oven Schematic-Cooking Condition
7
R-508CK R-510CK R-510CW
DESCRIPTION AND FUNCTION OF COMPONENTS
DOOR OPEN MECHANISM
The door is opened by pushing the open button on the control panel, refer to the Figure D-1. When the open button is pushed, the open button pushes up the switch lever, and then the switch lever pushes up the latch head. The latch heads are moved upward and released from latch hook. Now the door will open.
Latch Heads
Door
Switch Lever
Door Sensing  Switch
Monitor Switch
Secondary Interlock  Switch
Figure D-1. Door Open Mechanism
DOOR SENSING AND SECONDARY INTERLOCK SWITCHES
The secondary interlock switch is mounted in the lower position of the latch hook and the door sensing switch in the primary interlock system is mounted in the upper position of the latch hook. They are activated by the latch heads on the door. When the door is opened, the switches interrupt the power to all high voltage components. A cook cycle cannot take place until the door is firmly closed thereby activating both interlock switches. The primary interlock system con­sists of the door sensing switch and primary interlock relay located on the control circuit board.
MONITOR SWITCH
The monitor switch is activated (the contacts opened) by the latch head on the door while the door is closed. The switch is intended to render the oven inoperative, by means of blowing the monitor fuse, when the contacts of the primary interlock relay (RY2) and secondary interlock switch fail to open when the door is opened.
open, the monitor fuse blows simultaneously with closing of the monitor switch contacts.
CAUTION: BEFORE REPLACING A BLOWN MONITOR
FUSE TEST THE DOOR SENSING SWITCH, PRIMARY INTERLOCK RELAY (RY2), RELAY (RY1), SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH FOR PROPER OP­ERATION. (REFER TO CHAPTER "TEST PRO­CEDURE").
NOTE: MONITOR FUSE AND MONITOR SWITCH ARE
REPLACED AS AN ASSEMBLY.
TURNTABLE MOTOR
The turntable motor rotates the turntable located on the bottom of the oven cavity, so that the foods on the turntable cook evenly during cooking. The turntable may turn in either direction.
COOLING FAN MOTOR
The cooling fan motor drives a blade which draws external cool air. This cool air is directed through the air vanes surrounding the magnetron and cools the magnetron. This air is channelled through the oven cavity to remove steam and vapors given off from the heating foods. It is then exhausted through the exhausting air vents at the oven cavity.
MONITOR FUSE
1. The monitor fuse blows when the contacts (COM-NO) of the primary interlock relay (RY2) and secondary interlock switch remain closed with the oven door open and when the monitor switch closes.
2. If the wire harness or electrical components are short­circuited, this monitor fuse blows to prevent an electric shock or fire hazard.
CAVITY TEMPERATURE FUSE
The cavity temperature fuse located on the top of the oven cavity, is designed to prevent damage to the oven by fire. If the food load is overcooked, by either error in cook time or defect in the control unit, the cavity temperature fuse will open. Under normal operation, the cavity temperature fuse remains closed. However, when abnormally high temperatures are reached within the oven cavity, the cavity temperature fuse will open at 302˚F(150˚C) causing the oven to shut down. NOTE: This is a fuse. It does not reset.
Functions:
1. When the door is opened, the monitor switch contact close (to the ON condition) due to their being normally closed. At this time the primary interlock relay (RY2) and secondary interlock switch are in the OFF condition (contacts open) due to their being normally open contact switches.
2. As the door goes to a closed position, the monitor switch contacts are first opened and then the door sensing switch and the secondary interlock switch contacts close. (On opening the door, each of these switches operate inversely.)
3. If the door is opened, and the primary interlock relay (RY2) and secondary interlock switch contacts fail to
MAGNETRON TEMPERATURE FUSE
The magnetron temperature fuse located near the magnetron is designed to prevent damage to the magnetron if an over heated condition develops in the tube due to cooling fan failure, obstructed air guide, dirty or blocked air intake, etc. Under normal operation, the magnetron temperature fuse remains closed. However, when abnormally high tempera­tures are reached within the magnetron, the magnetron temperature fuse will open at 302˚F(150˚C) causing the oven to shut down. NOTE: This is a fuse. It does not reset.
8
R-508CK R-510CK R-510CW
TROUBLESHOOTING GUIDE
Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.
When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Procedure "section.
IMPORTANT: If the oven becomes inoperative because of a blown monitor fuse, check the monitor switch, relay (RY1)
primary interlock relay (RY2), door sensing switch and secondary interlock switch before replacing the monitor fuse. If the monitor fuse is replaced, the monitor switch must also be replaced. Use part FFS-BA016/ KIT as an assembly.
IMPORTANT: Whenever troubleshooting is performed with the power supply cord disconnected. It may in, some cases,
be necessary to connect the power supply cord after the outer case has been removed, in this event,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.
6. After that procedure, reconnect the power supply cord.
When the testing is completed
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Reconnect the leads to the primary of the power transformer.
5. Reinstall the outer case (cabinet).
6. Reconnect the power supply cord after the outer case is installed.
7. Run the oven and check all functions.
9
R-508CK R-510CK R-510CW
CK = Check / RE = Replace
CONDITION
OFF CONDITION
COOKING CONDITION
TEST PROCEDURE
AND
POSSIBLE CAUSE
DEFECTIVE PARTS
PROBLEM
Home fuse or circuit breaker blows when power cord is plugged into wall receptacle
Monitor fuse blows when power cord is plugged into wall receptacle.
All letters and indicators do not ap­pear in display when power cord is first plugged into wall outlet.
Display does not operate properly when STOP/CLEAR key is touched. (Buzzer should sound and ":" or time of day should appear in display.)
Oven lamp does not light when door is opened.
Oven lamp does not go out when door is closed.
Oven lamp lights but fan motor and turntable motor do not operate.
Oven does not go into cook cycle when START pad is touched
Oven seems to be operating but little or no heat is produced in oven load. (Food incompletely cooked or not cooked at all at end of cook cycle.)
Oven goes into a cook cycle but extremely uneven heating is pro­duced in oven load (food).
Oven does not cook properly when programmed for Cooking Power 5 mode. (Operates properly on Cook­ing Power 10 (HIGH) mode.)
Oven goes into COMPU DEFROST but food is not defrosted well.
RE RE
ABCDEEFFGH
SHORT IN POWER CORD
SHORT OR OPENED WIRING
MAGNETRON
POWER TRANSFORMER
H.V. RECTIFIER ASSEMBLY
RE RE CKICK CK CK
HIGH VOLTAGE CAPACITOR
CAVITY TEMPERATURE FUSE
MAGNETRON TEMPERATURE FUSE
PRIMARY INTERLOCK SYSTEM
SECONDARY INTERLOCK SWITCH
MONITOR SWITCH
MONITOR FUSE
OVEN LAMP OR SOCKET
COOLING FAN MOTOR
TURNTABLE MOTOR
TOUCH CONTROL PANEL
WRONG OPERATION
LOW VOLTAGE
JKLM
DIRTY OVEN CAVITY
KEY UNIT
RELAY (RY1)
COMPU DEFROST
FOIL PATTERN ON PWB.
PROCEDURE
LETTER
A MAGNETRON ASSEMBLY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
TEST PROCEDURES
COMPONENT TEST
10
Loading...