SHARP R-415EW, R-515EK. Service Manual

0 (0)

R-415EW

R- 515EK

SERVICE MANUAL

S91M172R415EE

MICROWAVEOVEN

MODELS R-415EW

R-515EK

R-415EW

In the interest of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used.

WARNING TO SERVICE PERSONNEL: Microwave ovens con-

tain circuitry capable of producing very high voltage and

current, contact with following parts may result in a severe,

possibly fatal, electrical shock. (High Voltage Capacitor, High

Voltage Power Transformer, Magnetron, High Voltage Recti-

fier Assembly, High Voltage Harness etc..)

R-515EK

 

TABLE OF CONTENTS

 

 

Page

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO

 

AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY ..................

INSIDE FRONT COVER

BEFORE SERVICING .....................................................................................................

INSIDE FRONT COVER

WARNING TO SERVICE PERSONNEL ..............................................................................................................

1

MICROWAVE MEASUREMENT PROCEDURE ..................................................................................................

2

FOREWORD AND WARNING .............................................................................................................................

3

PRODUCT SPECIFICATIONS .............................................................................................................................

4

GENERAL INFORMATION .................................................................................................................................

4

OPERATION ........................................................................................................................................................

6

TROUBLESHOOTING GUIDE .............................................................................................................................

9

TEST PROCEDURE ...........................................................................................................................................

10

TOUCH CONTROL PANEL ................................................................................................................................

18

COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE ................................................................

22

PICTORIAL DIAGRAM .......................................................................................................................................

28

POWER UNIT CIRCUIT......................................................................................................................................

29

CPU UNIT CIRCUIT............................................................................................................................................

30

PRINTED WIRING BOARD ................................................................................................................................

31

PARTS LIST ........................................................................................................................................................

33

PACKING AND ACCESSORIES .........................................................................................................................

37

This document has been published to be used for after

SHARP ELECTRONCS CORPORATION sales service only.

The contents are subject to change without notice.

Service Headquarters: Sharp Plaza, Mahwah, New Jersey, 07430-2135

R-415EW

R-515EK

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

(a)Do not operate or allow the oven to be operated with the door open.

(b)Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.

(c)Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.

(d)Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.

(e)A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner.

BEFORE SERVICING

Before servicing an operative unit, perform a microwave emission check as per the Microwave Measurement Procedure outlined in this service manual.

If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS CORPORATION immediately @1-800-237-4277.

If the unit operates with the door open, service person should 1) tell the user not to operate the oven and 2) contact SHARP ELECTRONICS CORPORATION and Food and Drug Administration's Center for Devices and Radiological Health immediately.

Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit found with emissions in excess of 4mW/cm2. The owner of the unit should be instructed not to use the unit until the oven has been brought into compliance.

R-415EW

R-515EK

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock.

(Example)

High Voltage Capacitor, High Voltage Power Trans-

former, Magnetron, High Voltage Rectifier Assem-

bly, High Voltage Harness etc..

Read the Service Manual carefully and follow all

instructions.

Don't Touch ! Danger High Voltage

Before Servicing

1. Disconnect the power supply cord

, and then

remove outer case.

 

2.Open the door and block it open.

3.Discharge high voltage capacitor.

WARNING:RISK OF ELECTRIC SHOCK. DISCHARGE THE HIGH-VOLTAGE CAPACITOR BEFORE SERVICING.

The high-voltage capacitor remains charged about 60 seconds after the oven has been switched off. Wait for 60 seconds and then short-circuit the connection of the highvoltage capacitor (that is the connecting lead of the highvoltage rectifier) against the chassis with the use of an insulated screwdriver.

Whenever troubleshooting is performed the power supply must be disconnected. It may, in some cases, be necessary to connect the power supply after the outer case has been removed, in this event:

1.Disconnect the power supply cord, and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

4.Disconnect the leads to the primary of the power transformer.

5.Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.

6.After that procedure, reconnect the power supply cord.

When the testing is completed,

1.Disconnect the power supply cord, and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

4.Reconnect the leads to the primary of the power transformer.

5.Reinstall the outer case (cabinet).

6.Reconnect the power supply cord after the outer case is installed.

7.Run the oven and check all functions.

After repairing

1.Reconnect all leads removed from components during testing.

2.Reinstall the outer case (cabinet).

3.Reconnect the power supply cord after the outer case is installed.

4.Run the oven and check all functions.

Microwave ovens should not be operated empty. To test for the presence of microwave energy within a cavity, place a cup of cold water on the oven turntable, close the door and set the power to HIGH and set the microwave timer for two

(2) minutes. When the two minutes has elapsed (timer at zero) carefully check that the water is now hot. If the water remains cold carry out Before Servicing procedure and reexamine the connections to the component being tested.

When all service work is completed and the oven is fully assembled, the microwave power output should be checked and a microwave leakage test should be carried out.

1

R-415EW

R-515EK

MICROWAVE MEASUREMENT PROCEDURE

A. Requirements:

1)Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven.

2)Safety interlock switches, primary interlock relay and door sensing switch shall prevent microwave radiation emission in excess of the requirement as above mentioned. Secondary interlock switch shall prevent microwave radiation emission in excess of 5 mW/cm2 at any point 5cm or more from the external surface of the oven.

B. Preparation for testing:

Before beginning the actual measurement of leakage, proceed as follows:

1) Make sure that the actual instrument is operating normally as specified in its instruction booklet.

Important:

Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for microwave ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.

2)Place the oven tray in the oven cavity.

3)Place the load of 275±15 ml (9.8 oz) of tap water initially at 20±5O C (68OF) in the center of the oven cavity.

The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-1/2 in.) and made of an electrically nonconductive material such as glass or plastic.

The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage is measured accurately.

4)Set the cooking control on Full Power Cooking Mode.

5)Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed, replace it with 275 ml of cool water.

C. Leakage test:

Closed-door leakage test (microwave measurement):

1)Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven.

2)Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on the meter.

3)Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity of the metal has been breached (eg., around the switches, indicator, and vents).

While testing for leakage around the door, pull the door away from the front of the oven as far as is permitted by the closed latch assembly.

4)Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm2, and that the secondary interlock switch does turn the oven OFF before any door movement.

NOTE: After servicing, record data on service invoice and microwave leakage report.

2

SERVICE MANUAL

MICROWAVE OVEN

R-415EW&R-515EK

FOREWORD

This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVENS, R-415EW and R-515EK.

It is recommended that service personnel carefully study the entire text of this manual so that they will be qualified to render satisfactory customer service.

Check the interlock switches and the door seal carefully. Special attention should be given to avoid electrical shock and microwave radiation hazard.

WARNING

Never operate the oven until the following points are ensured:

(A)The door is tightly closed.

(B)The door brackets and hinges are not defective.

(C)The door packing is not damaged.

(D)The door is not deformed or warped.

(E)There is no other visible damage with the oven.

Servicing and repair work must be carried out only by trained service

personnel.

DANGER

Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing. Service personnel - Do not contact the following parts while the appliance is energized;

High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness;

If provided, Vent Hood, Fan assembly, Cooling Fan Motor.

All the parts marked “*” on parts list are used at voltages more than 250V.

Removal of the outer wrap gives access to voltage above 250V.

All the parts marked “” on parts list may cause undue microwave exposure, by themselves, or when they are damaged, loosened or removed.

SHARP ELECTRONICS CORPORATION

SHARP PLAZA, MAHWAH,

NEW JERSEY 07430-2135

3

R-415EW

R-515EK

PRODUCTDESCRIPTION

GENERALINFORMATION

OPERATION

TROUBLESHOOTINGGUIDEAND TEST PROCEDURE

TOUCH CONTROL PANEL

COMPONENTREPLACEMENT ANDADJUSTMENTPROCEDURE

WIRINGDIAGRAM

PARTS LIST

R-415EW

R-515EK

 

SPECIFICATION

 

 

 

ITEM

 

 

 

DESCRIPTION

 

 

PowerRequirements

120 Volts

 

 

 

 

 

 

13.8 Amperes, 1650 watts - (R-415EW & R-515EK)

 

 

 

60 Hertz

 

 

 

 

 

 

Single phase, 3 wire grounded

 

 

 

 

 

 

 

Power Output

1200 watts (IEC 705 TEST PROCEDURE) - (R-415EW/R-515EK)

 

Operating frequency of 2450MHz

 

 

 

 

 

 

 

 

 

Case Dimensions

Width 21-21/32" (R-415EW)

 

Width 24"

(R-515EK)

 

Height 12-3/8"

(R-415EW)

 

Height 13-3/8"

(R-515EK)

 

Depth 18-7/16"

(R-415EW)

 

Depth 19-1/8"

(R-515EK)

 

 

 

 

 

 

 

Cooking Cavity Dimensions

Width 15-23/32"

(R-415EW)

 

Width 17-3/8"

(R-515EK)

1.6 Cubic Feet (R-415EW)

Height 9-21/32"

(R-415EW)

 

Height 10-1/2"

(R-515EK)

2.0 Cubic Feet (R-515EK)

Depth 17-7/8"

(R-415EW)

Depth 18-5/8"

(R-515EK)

ControlComplement

Touch Control System

(R-415EW & R-515EK)

 

 

 

Clock ( 1:00 - 12:59 )

 

 

 

 

 

Timer (0 - 99 min. 99 seconds)

 

 

 

 

 

Microwave Power for Variable Cooking

 

 

 

Repetition Rate;

 

 

 

 

 

 

P-HI ..................................................

 

 

Full power throughout the cooking time

 

P-90 ....................................................................

 

 

approx.

90% of Full Power

 

P-80 ....................................................................

 

 

approx.

80% of Full Power

 

P-70 ....................................................................

 

 

approx.

70% of Full Power

 

P-60 ....................................................................

 

 

approx.

60% of Full Power

 

P-50 ....................................................................

 

 

approx.

50% of Full Power

 

P-40 ....................................................................

 

 

approx.

40% of Full Power

 

P-30 ....................................................................

 

 

approx.

30% of Full Power

 

P-20 ....................................................................

 

 

approx.

20% of Full Power

 

P-10 ....................................................................

 

 

approx.

10% of Full Power

 

P-0 ......................................................

 

 

No power throughout the cooking time

 

POPCORN pad, MINUTE PLUS pad, INSTANT ACTION pads

 

COMPU DEFROST pads, Number selection pads Power Level pad, Timer/Clock

 

pad,Stop/Clear pad, START pad, Keep warm & Reheat

 

Oven Cavity Light

Yes

 

 

 

 

 

 

 

 

 

 

Safety Standard

UL Listed

FCC Authorized

 

 

 

DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J

 

 

 

 

 

 

 

 

 

GENERAL INFORMATION

GROUNDING INSTRUCTIONS

This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances.

In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.

WARNING: Improper use of the grounding plug can result in a risk of electric shock.

Electrical Requirements

The electrical requirements are a 120 volt 60 Hz, AC only,

15 or 20 amp. fused electrical supply. It is recommended that a separate circuit serving only this appliance be provided. When installing this appliance, observe all applicable codes and ordinances.

A short power-supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord.

Where a two-pronged wall-receptacle is encountered, it is the personal responsibility and obligation of the customer to contact

4

a qualified electrician and have it replaced with a properly grounded three-pronged wall receptacle or have a grounding adapter properly grounded and polarized. If the extension cord must be used, it should be a 3-wire, 15 amp. or higher rated cord. Do not drape over a countertop or table where it can be pulled on by children or tripped over accidentally.

CAUTION: DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE ROUND GROUNDING PRONG FROM THIS PLUG.

1.One touch door open button. Push to open door.

2.Door latches.

The oven will not operate unless the door is securely closed.

3.Removable turntable support.

4.Removable turntable.

The turntable will rotate clockwise or counterclockwise.

5.Oven lamp.

It will light when oven is operating or door is opened.

6.Oven door with see-through window.

7.Ventilation openings. (Rear)

8.Auto-Touch control panel.

9.Time display: Digital display, 99 minutes 99 seconds.

OVEN DIAGRAM

6

5

2

10

4

3

10.Wave guide cover.

11.Power supply cord

TOUCH CONTROL PANEL

See NOTE

See NOTE

See NOTE

NOTE:

The directed features are disa-

bled after three minutes when the oven is not in use. These features

are automatically enabled when the door is opened and closed or

the STOP/ CLEAR pad is pressed.

R-415EW

R-415EW

R-515EK

Grounded

Receptacle Box

3-Pronged Plug

Grounding Pin

3-Pronged Receptacle

7

11

9

8

1

See NOTE

See NOTE

See NOTE

R-515EK

5

R-415EW

R-515EK

OPERATION

DESCRIPTION OF OPERATING SEQUENCE

The following is a description of component functions during oven operation.

OFF CONDITION

Closing the door activates the door sensing switch and secondary interlock switch. (In this condition, the monitor switch contacts are opened.)

When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1).

1.The display will show flashing "88:88".

To set any program or set the clock, you must first touch the STOP/CLEAR pad. The display will clear, and " : " will appear.

COOKING CONDITION

Program desired cooking time by touching the NUMBER pads. Program the power level by touching the POWER LEVEL pad.

When the START pad is touched, the following operations occur:

1.

The contacts of relays are closed and components

 

connected to the relays are turned on as follows.

 

(For details, refer to Figure O-2)

 

 

 

 

 

 

RELAY

CONNECTED COMPONENTS

 

 

 

 

 

 

RY-1

oven lamp/turntable motor/fan motor

 

 

 

 

 

 

RY-2

power transformer

2.

120 volts A.C. is supplied to the primary winding of the

 

power transformer and is converted to about 3.3 volts

 

A.C. output on the filament winding, and approximately

 

2370 volts A.C. on the high voltage winding.

3.

Thefilamentwindingvoltageheatsthemagnetronfilament

 

and the H.V. winding voltage is sent to a voltage doubler

 

circuit.

 

4.

The microwave energy produced by the magnetron is

 

channelled through the waveguide into the cavity feed-

 

box, and then into the cavity where the food is placed to

 

be cooked.

 

5.

Upon completion of the cooking time, the power

 

transformer, oven lamp, etc. are turned off, and the

 

generation of microwave energy is stopped. The oven

 

will revert to the OFF condition.

6.

When the door is opened during a cook cycle, the monitor

 

switch, door sensing switch, secondary interlock switch,

 

relay (RY1) and primary interlock relay are activated with

 

the following results. The circuits to the turntable motor,

 

the cooling fan motor, and the high voltage components

 

are de-energized, the oven lamp remains on, and the

 

digital read-out displays the time still remaining in the

 

cook cycle when the door was opened.

7.

The monitor switch electrically monitors the operation of

 

the secondary interlock switch and primary interlock

relay and is mechanically associated with the door so that it will function in the following sequence.

(1)When the door opens from the closed position, the primary interlock relay (RY2) and secondary interlock switch open their contacts. And contacts of the relay (RY1) remains closed. Then the monitor switch contacts close.

(2)When the door is closed from the open position, the monitor switch contacts open first. Then the contacts of the secondary interlock switch and door sensing switch close. And contacts of the relay (RY1) open.

If the secondary interlock switch and primary interlock relay (RY2) fail with the contacts closed when the door is opened, the closing of the monitor switch contacts will form a short circuit through the monitor fuse, secondary interlock switch, relay (RY1) and primary interlock relay (RY2), causing the monitor fuse to blow.

POWER LEVEL P-0 TO P-90 COOKING

When Variable Cooking Power is programmed, the 120 volts A.C. is supplied to the power transformer intermittently through the contacts of relay (RY-2) which is operated by the control unit within a 32 second time base. Microwave power operation is as follows:

VARI-MODE

ON TIME

OFF TIME

Power 10(P-HI)

32 sec.

0 sec.

(100% power)

 

 

Power 9(P-90)

30 sec.

2 sec.

(approx. 90% power)

 

 

Power 8(P-80)

26 sec.

6 sec.

(approx. 80% power)

 

 

Power 7(P-70)

24 sec.

8 sec.

(approx. 70% power)

 

 

Power 6(P-60)

22 sec.

10 sec.

(approx. 60% power)

 

 

Power 5(P-50)

18 sec.

14 sec.

(approx. 50% power)

 

 

Power 4(P-40)

16 sec.

16 sec.

(approx. 40% power)

 

 

Power 3(P-30)

12 sec.

20 sec.

(approx. 30% power)

 

 

Power 2(P-20)

8 sec.

24 sec.

(approx. 20% power)

 

 

Power 1(P-10)

6 sec.

26 sec.

(approx. 10% power)

 

 

Power 0(P-0)

0 sec.

32 sec.

(0% power)

 

 

Note: The ON/OFF time ratio does not correspond with the percentage of microwave power, because approx. 2 seconds are needed for heating of the magnetron filament.

6

R-415EW

R-515EK

Note:* Indicates component

SCHEMATIC

NOTE: CONDITION OF OVEN

1.Door Closed

2.CLOCK APPEARS ON DISPLAY

MAGNETRON

MONITOR

 

 

 

 

 

TEMP.

 

 

 

 

 

FUSE

FUSE 20A

 

 

 

 

 

 

 

COM.

N.O.

 

 

 

A2

 

 

 

 

 

 

 

 

 

 

 

CAPACITOR 1.0µF

 

 

 

 

 

 

AC 2300V

 

A1

(RY-1)

 

 

(RY-2)

 

 

 

 

 

PRIMARY

 

 

 

 

 

 

INTERLOCK

 

 

 

 

 

 

RELAY

 

GRN

CONTROL UNIT

 

 

 

 

 

 

N.O.

COM.

 

 

120V AC

 

 

 

B1

B2

POWER

60 Hz

 

 

 

TRANSFORMER

 

 

 

 

 

DOOR

N.C.

 

 

 

 

 

 

CAVITY

 

 

 

 

SENSING

MONITOR

TEMP.

 

 

 

 

SWITCH

SWITCH

FUSE

OL

TTM

FM

 

COM.

 

 

 

 

 

 

 

 

H.V. RECTIFIER

 

OVEN

TURN-

 

FAN

 

MAGNETRON

 

 

 

 

 

LAMP

TABLE

 

MOTOR

 

 

 

 

MOTOR

 

 

 

 

 

SECONDARY

 

 

 

 

 

 

INTERLOCK

 

 

 

 

 

 

SWITCH

 

 

 

 

 

Figure O-1 Oven Schematic - Off Condition

SCHEMATIC

NOTE: CONDITION OF OVEN

1.DOOR CLOSED

2.COOKING TIME PROGRAMMED

3.VARIABLE COOKING CONTROL "HIGH"

4."START" PAD TOUCHED

MAGNETRON

MONITOR

TEMP.

FUSE

FUSE 20A

 

 

 

 

 

 

 

COM.

N.O.

 

 

A2

 

 

 

 

 

 

 

 

 

 

CAPACITOR 1.0µF

 

 

 

 

 

AC 2300V

A1

(RY-1)

 

 

(RY-2)

 

 

 

 

PRIMARY

 

 

 

 

 

INTERLOCK

 

 

 

 

 

RELAY

 

GRN

 

 

 

 

 

CONTROL UNIT

N.O.

COM.

 

 

120V AC

 

 

B1

B2

POWER

60 Hz

 

 

TRANSFORMER

 

 

 

 

DOOR

N.C.

 

 

 

 

 

CAVITY

 

 

 

SENSING

MONITOR

TEMP.

 

 

 

SWITCH

SWITCH

FUSE

TTM

FM

 

 

OL

 

COM.

 

 

 

 

 

H.V. RECTIFIER

OVEN

TURN-

 

FAN

 

MAGNETRON

 

 

 

LAMP

TABLE

 

MOTOR

 

 

 

MOTOR

 

 

 

 

SECONDARY

 

 

 

 

 

INTERLOCK

 

 

 

 

 

SWITCH

 

 

 

 

 

Figure O-2 Oven Schematic - Cooking Condition

7

R-415EW

R-515EK

DESCRIPTION AND FUNCTION OF COMPONENTS

DOOR OPEN MECHANISM

The door is opened by pushing the open button on the control panel, refer to the Figure D-1. When the open button is pushed, the open button pushes up the switch lever, and then the switch lever pushes up the latch head. The latch heads are moved upward and released from latch hook. Now the door will open.

Latch Heads

Door Sensing

Door

Switch

Monitor Switch

Switch Lever

Secondary Interlock

Switch

Figure D-1. Door Open Mechanism

DOOR SENSING AND SECONDARY INTERLOCK SWITCHES

The secondary interlock switch is mounted in the lower position of the latch hook and the door sensing switch in the primary interlock system is mounted in the upper position of the latch hook. They are activated by the latch heads on the door. When the door is opened, the switches interrupt the power to all high voltage components. A cook cycle cannot take place until the door is firmly closed thereby activating both interlock switches. The primary interlock system consists of the door sensing switch and primary interlock relay located on the control circuit board.

MONITOR SWITCH

The monitor switch is activated (the contacts opened) by the latch head on the door while the door is closed. The switch is intended to render the oven inoperative, by means of blowing the monitor fuse, when the contacts of the primary interlock relay (RY2) and secondary interlock switch fail to open when the door is opened.

Functions:

1.When the door is opened, the monitor switch contact close (to the ON condition) due to their being normally closed. At this time the primary interlock relay (RY2) and secondary interlock switch are in the OFF condition (contacts open) due to their being normally open contact switches.

2.As the door goes to a closed position, the monitor switch contacts are first opened and then the door sensing switch and the secondary interlock switch contacts close. (On openingthedoor,eachoftheseswitchesoperateinversely.)

3.If the door is opened, and the primary interlock relay (RY2) and secondary interlock switch contacts fail to

open, the monitor fuse blows simultaneously with closing of the monitor switch contacts.

CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE TEST THE DOOR SENSING SWITCH, PRIMARY INTERLOCK RELAY (RY2), RELAY (RY1), SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH FOR PROPER OPERATION. (REFER TO CHAPTER "TEST PROCEDURE").

NOTE: MONITOR FUSE AND MONITOR SWITCH ARE REPLACED AS AN ASSEMBLY.

TURNTABLE MOTOR

The turntable motor rotates the turntable located on the bottom of the oven cavity, so that the foods on the turntable cook evenly during cooking. The turntable may turn in either direction.

COOLING FAN MOTOR

Thecoolingfanmotordrivesabladewhichdrawsexternalcool air. This cool air is directed through the air vanes surrounding themagnetronandcoolsthemagnetron.Thisairischannelled through the oven cavity to remove steam and vapors given off from the heating foods. It is then exhausted through the exhausting air vents at the oven cavity.

MONITOR FUSE

1.The monitor fuse blows when the contacts (COM-NO) of the primary interlock relay (RY2) and secondary interlock switch remain closed with the oven door open and when the monitor switch closes.

2.If the wire harness or electrical components are shortcircuited, this monitor fuse blows to prevent an electric shock or fire hazard.

CAVITY TEMPERATURE FUSE

The cavity temperature fuse located on the top of the oven cavity, is designed to prevent damage to the oven by fire. If the food load is overcooked, by either error in cook time or defect in the control unit, the cavity temperature fuse will open.

Under normal operation, the cavity temperature fuse remains closed. However, when abnormally high temperatures are reachedwithintheovencavity,thecavitytemperaturefusewill open at 302OF(150OC) causing the oven to shut down.

NOTE: This is fuse. It does not reset.

Magnetron TEMPERATURE FUSE

The magnetron temperature fuse located near the magnetron is designed to prevent damage to the magnetron if an over heatedconditiondevelopsinthetubeduetocoolingfanfailure, obstructed air guide, dirty or blocked air intake, etc.

Under normal operation, the magnetron temperature fuse remains closed. However, when abnormally high temperatures are reached within the magnetron, the magnetron temperature fuse will open at 302OF(150OC) causing the oven to shut down.

NOTE: This is fuse. It does not reset.

8

R-415EW

R-515EK

TROUBLESHOOTING GUIDE

Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.

When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Procedure "section.

IMPORTANT: If the oven becomes inoperative because of a blown monitor fuse, check the monitor switch, relay (RY1) primary interlock relay (RY2), door sensing switch and secondary interlock switch before replacing the monitor fuse. If the monitor fuse is replaced, the monitor switch must also be replaced. Use part FFS-BA016/ KIT as an assembly.

IMPORTANT: Whenever troubleshooting is performed with the power supply cord disconnected. It may in, some cases, be necessary to connect the power supply cord after the outer case has been removed, in this event:

1.Disconnect the power supply cord, and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

4.Disconnect the leads to the primary of the power transformer.

5.Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.

6.After that procedure, reconnect the power supply cord.

When the testing is completed

1.Disconnect the power supply cord, and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

4.Reconnect the leads to the primary of the power transformer.

5.Reinstall the outer case (cabinet).

6.Reconnect the power supply cord after the outer case is installed.

7.Run the oven and check all functions.

9

SHARP R-415EW, R-515EK. Service Manual

R-415EW

R-515EK

CK = Check / RE = Replace

 

TEST PROCEDURE

RE RE A

B

C

D

E

E

F

F

G

H RE RE CK

I

CK CK CK J

K

L

M

CONDITION

PROBLEM POSSIBLECAUSEANDDEFECTIVEPARTS

SHORT IN POWER CORD SHORT OR OPENED WIRING MAGNETRON

POWER TRANSFORMER

H.V. RECTIFIER ASSEMBLY

HIGH VOLTAGE CAPACITOR

CAVITY TEMPERATURE FUSE

MAGNETRON TEMPERATURE FUSE

PRIMARY INTERLOCK SYSTEM

SECONDARY INTERLOCK SWITCH

MONITOR SWITCH

MONITOR FUSE OVEN LAMP OR SOCKET COOLING FAN MOTOR TURNTABLE MOTOR

TOUCH CONTROL PANEL

WRONG OPERATION LOW VOLTAGE DIRTY OVEN CAVITY KEY UNIT

RELAY (RY1)

COMPU DEFROST

FOIL PATTERN ON PWB.

Home fuse or circuit breaker blows when power cord is plugged into wall receptacle

Monitor fuse blows when power cord is plugged into wall receptacle.

OFF

CONDITION All letters and indicators do not appear in display when power cord is first plugged into wall outlet.

Display does not operate properly when STOP/CLEAR key is touched. (Buzzer should sound and ":" or time of day should appear in display.)

Oven lamp does not light when door is opened.

Oven lamp does not go out when door is closed.

Oven lamp lights but fan motor and turntable motor do not operate.

Oven does not go into cook cycle when START pad is touched

Oven seems to be operating but little or no heat is produced in oven load.

(Food incompletely cooked or not cooked at all at end of cook cycle.)

COOKING Oven goes into a cook cycle but CONDITION extremely uneven heating is pro-

duced in oven load (food).

Oven does not cook properly when programmed for Cooking Power P- 50 mode. (Operates properly on Cooking P-HI (HIGH) mode.)

Oven goes into COMPU DEFROST but food is not defrosted well.

TEST PROCEDURES

PROCEDURE

COMPONENT TEST

LETTER

 

AMAGNETRON ASSEMBLY TEST

1.Disconnect the power supply cord, and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

10

Loading...