SHARP R200BK, R-200BW Service Manual

SER VICE MANU AL
S1802R200BPW/
MICROWAVE OVEN
R-200BK R-200BW
1
40
20
0
BAKED POTATO
COOK 1 medium
FRESH
VEGETABLES
COOK 2 cups
POPCORN
POP 3.5 oz. bag
U
t
h
g
i
L
2
1
5
1
4
1
3
DINNER
PLATE
REHEAT
SOUP
REHEAT
1 cup
ROLL/
MUFFIN
REHEAT
1 medium
DEFROST
Check chart in Operation Manual
MODELS
4 5
min.
6 8
min.
3 4
min.
p
D
i
a
l
3
4
5
6 7 8
9
10
11
12
3 4
min.
6 8
min.
20
sec.
In the interest of user-safety the oven should be restored to its original condition and only parts identical to those specified should be used.
R-200BK R-200BW
WARNING TO SERVICE PERSONNEL: Microwave ovens con­tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Recti­fier Assembly, High Voltage Harness etc..)
TABLE OF CONTENTS
Page PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO
AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY ...................INSIDE FRONT COVER
BEFORE SERVICING ......................................................................................................INSIDE FRONT COVER
WARNING TO SERVICE PERSONNEL................................................................................................................1
MICROWAVE MEASUREMENT PROCEDURE ...................................................................................................2
FOREWORD AND WARNING...............................................................................................................................3
PRODUCT SPECIFICATIONS ..............................................................................................................................4
GENERAL INFORMATION...................................................................................................................................4
OPERATION..........................................................................................................................................................6
TROUBLESHOOTING GUIDE ..............................................................................................................................9
TEST PROCEDURE ............................................................................................................................................10
TOUCH CONTROL PANEL .................................................................................................................................16
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE ................................................................20
PICTORIAL DIAGRAM ........................................................................................................................................26
CONTROL PANEL CIRCUIT ...............................................................................................................................27
PRINTED WIRING BOARD .................................................................................................................................28
PARTS LIST ........................................................................................................................................................29
PACKING AND ACCESSORIES .........................................................................................................................31
SHARP CORPORATION
This document has been published to be used for after sales service only. The contents are subject to change without notice.
R-200BK R-200BW
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave
generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to releasing oven to the owner.
BEFORE SERVICING
Before servicing an operative unit, perform a microwave emission check as per the Microwave Measurement Procedure outlined in this service manual. If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS CORPORATION immediately @1-800-237-4277.
If the unit operates with the door open, service person should 1) tell the user not to operate the oven and 2) contact SHARP ELECTRONICS CORPORATION and Food and Drug Administration's Center for Devices and Radiological Health immediately.
Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit found with emissions in excess of 4mW/cm2. The owner of the unit should be instructed not to use the unit until the oven has been brought into compliance.
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro­ducing very high voltage and current, contact with following parts fatal, electrical shock.
(Example) High Voltage Capacitor, High Voltage Power Trans-
former, Magnetron, High Voltage Rectifier Assem­bly, High Voltage Harness etc..
Read the Service Manual carefully and follow all instructions.
may result in a severe, possibly
Don't Touch ! Danger High Voltage
R-200BK R-200BW
Before Servicing
1. Disconnect the power supply cord , and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
WARNING:RISK OF ELECTRIC SHOCK.
DISCHARGE THE HIGH-VOLTAGE CAPACITOR BEFORE SERVICING.
The high-voltage capacitor remains charged about 60 seconds after the oven has been switched off. Wait for 60 seconds and then short-circuit the connection of the high­voltage capacitor (that is the connecting lead of the high­voltage rectifier) against the chassis with the use of an insulated screwdriver.
Wherever troubleshooting is performed the power supply must be disconnected. It may in, some cases, be necessary to connect the power supply after the outer case has been removed, in this event,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.
6. After that procedure, reconnect the power supply cord.
When the testing is completed,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Reconnect the leads to the primary of the power transformer.
5. Reinstall the outer case (cabinet).
6. Reconnect the power supply cord after the outer case is installed.
7. Run the oven and check all function.
After repairing
1. Reconnect all leads removed from components during testing.
2. Reinstall the outer case (cabinet).
3. Reconnect the power supply cord after the outer case is installed.
4. Run the oven and check all functions.
Microwave ovens should not be run empty. To test for the presence of microwave energy within a cavity, place a cup of cold water on the oven turntable, close the door and set the power to HIGH and set the microwave timer for two (2) minutes. When the two minutes has elapsed (timer at zero) carefully check that the water is now hot. If the water remains cold carry out Before Servicing procedure and re­examine the connections to the component being tested.
When all service work is completed and the oven is fully assembled, the microwave power output should be checked and microwave leakage test should be carried out.
1
R-200BK R-200BW
MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven.
2) Safety interlock switches Primary interlock relay and door sensing switch shall prevent microwave radiation emission in excess of the requirement as above mentioned, secondary interlock switch shall prevent microwave radiation emission in excess of 5 mW/cm2 at any point 5cm or more from the external surface of the oven.
B. Preparation for testing: Before beginning the actual measurement of leakage, proceed as follows:
1) Make sure that the actual instrument is operating normally as specified in its instruction booklet. Important:
Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for microwave ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.
2) Place the oven tray in the oven cavity.
3) Place the load of 275±15 ml (9.8 oz) of tap water initially at 20±5˚C (68˚F) in the center of the oven cavity.
The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-1/2 in.) and made of an electrically nonconductive material such as glass or plastic. The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage is measured accurately.
4) Set the cooking control on Full Power Cooking Mode
5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed,
replace it with 275 ml of cool water.
C. Leakage test:
Closed-door leakage test (microwave measurement)
1) Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven.
2) Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on the meter.
3) Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity of the metal has been breached (eg., around the switches, indicator, and vents). While testing for leakage around the door pull the door away from the front of the oven as far as is permitted by the closed latch assembly.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm2, and that the secondary interlock switch does turn the oven OFF before any door movement.
NOTE: After servicing, record data on service invoice and microwave leakage report.
2
SERVICE MANUAL
MICROWAVE OVEN
PRODUCT DESCRIPTION
R-200BK R-200BW
R-200BK/ R-200BW
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVEN, R-200BK, R-200BW.
It is recommended that service personnel carefully study the entire text of this manual so that they will be qualified to render satisfactory customer service.
Check the interlock switches and the door seal carefully. Special attention should be given to avoid electrical shock and microwave radiation hazard.
WARNING
Never operate the oven until the following points are ensured. (A) The door is tightly closed. (B) The door brackets and hinges are not defective. (C) The door packing is not damaged. (D) The door is not deformed or warped. (E) There is not any other visible damage with the oven.
Servicing and repair work must be carried out only by trained service personnel.
DANGER
Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing. Service personnel - Do not contact the following parts while the appliance is energized; High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness; If provided, Vent Hood, Fan assembly, Cooling Fan Motor.
GENERAL INFORMATION
OPERATION
TROUBLESHOOTING GUIDE AND TEST PROCEDURE
TOUCH CONTROL PANEL
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
WIRING DIAGRAM
PARTS LIST
All the parts marked “*” on parts list are used at voltages more than 250V.
Removal of the outer wrap gives access to voltage above 250V. All the parts marked “” on parts list may cause undue microwave
exposure, by themselves, or when they are damaged, loosened or removed.
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
3
R-200BK R-200BW
PRODUCT DESCRIPTION
SPECIFICATIONS
ITEM DESCRIPTION
Power Requirements 120 Volts
60 Hertz
Single phase, 3 wire grounded Power Consumption 1030W / Approx. 9.0 Amperes Power Output 600 W nominal of RF microwave energy (IEC 705 Test procedure)
Operating frequency 2450 MHz Case Dimensions Width 18-1/8"
Height 11-3/8"
Depth 14-5/8" Cooking Cavity Dimensions Width 12-3/8"
(0.7 Cubic feet) Height 7-7/8"
Depth 12-5/8" Control Complement Light up dial timer (15 minutes)
No cooking control Oven Cavity Light Yes Safety Standard UL Listed.
FCC Authorized
DHHS RUles, CFR, Title 21, Chapter 1, Subchapter J
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements The electrical requirements are a 115 -120 volt 60 Hz, AC only, 15 or 20 amp. fused electrical supply. It is recommended that a separate circuit serving only this appliance be provided. When installing this appliance, observe all applicable codes and ordinances. A short power-supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord. Where a two-pronged wall-receptacle is encountered, it is the personal responsibility and obligation of the customer to contact a qualified electrician and have it replaced with a properly grounded three-pronged wall receptacle or have a grounding adapter properly grounded and polarized. If the extension cord must be used, it should be a 3-wire, 15 amp. or higher rated cord. Do not drape over a countertop or table where it can be pulled on by children or tripped over accidentally.
CAUTION: DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE ROUND GROUNDING PRONG FROM
THIS PLUG.
3-Pronged Plug
Grounded Receptacle Box
Grounding Pin
3-Pronged Receptacle
4
OVEN DIAGRAM
R-200BK R-200BW
1. Oven door with see-through window
2. Safety door latches.
3. Door hinges
4. Door seals and sealing surfaces
5. Turntable motor shaft
6. Removable turntable support
7. Removable turntable
8. Ventilation openings. (Rear)
9. Oven lamp.
10.Wave guide cover.
11.Power supply cord
9
3
1
2
4
CONTROL PANEL
BAKED POTATO
COOK 1 medium
FRESH VEGETABLES
COOK 2 cups
POPCORN
POP 3.5 oz. bag
4 5min.
6 8min.
3 4min.
8
10
7
11
6
5
t
h
g
i
L
2
1
40
20
0
1
5
1
4
DINNER PLATE
REHEAT 3 4min.
SOUP
REHEAT
1 cup
ROLL/
MUFFIN
REHEAT
1 medium
DEFROST
Check chart in Operation Manual
U
p
D
i
a
l
3
4
5
6 7
8
9
10
11
12
1
3
4 5min.
20sec.
5
R-200BK R-200BW
OPERATION
DESCRIPTION OF OPERATING SEQUENCE
The following is a description of component functions during oven operation.
OFF CONDITION
Closing the door activates door sensing switch and second­ary interlock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1).
COOKING CONDITION
When the Light Up Dial is turned, the following operations occur:
1. The contacts of the relay are closed and components connected to the relay are turned on as follows. (For details, refer to Figure O-2)
RELAY CONNECTED COMPONENTS RY-1 oven lamp/turntable motor/fan motor
power transformer
2. 120 volts A.C. is supplied to the primary winding of the power transformer and is converted to about 3.5 volts A.C. output on the filament winding, and approximately 2000 volts A.C. on the high voltage winding.
3. The filament winding voltage heats the magnetron filament and the H.V. winding voltage is sent to a voltage doubler circuit.
4. The microwave energy produced by the magnetron is channelled through the waveguide into the cavity feed-
box, and then into the cavity where the food is placed to be cooked.
5. Upon completion of the cooking time, the power transformer, oven lamp, etc. are turned off, and the generation of microwave energy is stopped. The oven will revert to the OFF condition.
6. When the door is opened during a cook cycle, monitor switch, door sensing switch, secondary interlock switch and primary interlock relay (RY1) are activated with the following results. The circuits to the oven lamp, turntable motor, the cooling fan motor, and the high voltage components are de-energized, and the Light Up Dial indicates the time still remaining in the cook cycle when the door was opened.
7. The monitor switch is electrically monitoring the operation of the primary interlock relay (RY1) and the secondary interlock switch and is mechanically associated with the door so that it will function in the following sequence.
(1) When the door opens from the closed position, the
secondary interlock switch, door sensing switch and primary interlock relay (RY1) open their contacts. Then the monitor switch contacts close.
(2) When the door is closed from the open position, the
monitor switch contacts open first. Then the contacts of the secondary interlock switch and door sensing
switch close. If the secondary interlock switch and primary interlock relay (RY1) fail with the contacts closed when the door is opened, the closing of the monitor switch contacts will form a short circuit through the C/T fuse and primary interlock relay (RY1), causing the C/T fuse to blow.
SCHEMATIC
NOTE: CONDITION OF OVEN
1. LIGHT UP DIAL OFF.
2. DOOR CLOSED.
A3
120V AC 60 Hz
C/T FUSE
CONTROL UNIT
SECONDARY INTERLOCK SWITCH
MAGNETRON  THERMAL CUT-OUT
COM.
(RY-1)
A1 A3
PRIMARY INTERLOCK RELAY
DOOR SENSING SWITCH
N.O.
OL
OVEN LAMP
TTM
TURN- TABLE MOTOR
FM
FAN  MOTOR
Figure O-1. Oven Schematic-Off Condition
6
MONITOR  SWITCH
POWER  TRANSFORMER
CAPACITOR
0.72µF
RECTIFIER
MAGNETRON
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED.
2. LIGHT UP DIAL ON.
R-200BK R-200BW
120V AC 60 Hz
C/T FUSE
A3
CONTROL UNIT
SECONDARY INTERLOCK SWITCH
MAGNETRON  THERMAL CUT-OUT
(RY-1)
COM.
PRIMARY INTERLOCK RELAY
A1 A3
DOOR SENSING SWITCH
N.O.
Figure O-2. Oven Schematic-Cooking Condition
DESCRIPTION AND FUNCTION OF COMPONENTS
DOOR OPEN MECHANISM
The door is opened by pulling the door, refer to the Figure D-1.
Latch Heads 
Latch Hook
POWER  TRANSFORMER
OL
OVEN LAMP
TTM
TURN- TABLE MOTOR
FM
FAN  MOTOR
MONITOR  SWITCH
CAPACITOR
0.72µF
RECTIFIER
MAGNETRON
MONITOR SWITCH
The monitor switch is activated (the contacts opened) by the latch head on the door while the door is closed. The switch is intended to render the oven inoperative, by means of blowing the C/T fuse, when the contacts of the primary interlock relay (RY1) and secondary interlock switch fail to open when the door is opened.
Door Sensing Switch
Monitor
Door
Secondary Interlock
Switch
Switch
Figure D-1. Door Open Mechanism
DOOR SENSING AND SECONDARY INTERLOCK SWITCHES
The secondary interlock switch is mounted in the lower position of the latch hook and the door sensing switch in the primary interlock system is mounted in the upper position of the latch hook. They are activated by the latch heads on the door. When the door is opened, the switches interrupt the power to all high voltage components. A cook cycle cannot take place until the door is firmly closed thereby activating both interlock switches. The primary interlock system con­sists of the door sensing switch and primary interlock relay located on the control circuit board.
Functions:
1. When the door is opened, the monitor switch contacts close (to the ON condition) due to their being normally closed. At this time the primary interlock relay (RY1) and secondary interlock switch are in the OFF condition (contacts open) due to its being normally open contact switches.
2. As the door goes to a closed position, the monitor switch contacts are first opened and then the door sensing switch and secondary interlock switch contacts close.
3. If the door is opened, and the primary interlock relay (RY1) and the secondary interlock switch contact fail to open, the C/T fuse blows simultaneously with closing of the monitor switch contacts.
CAUTION: BEFORE REPLACING A BLOWN C/T FUSE,
TEST THE DOOR SENSING SWITCH, PRI­MARY INTERLOCK RELAY (RY1), SECOND­ARY INTERLOCK SWITCH AND MONITOR SWITCH FOR PROPER OPERATION. (RE­FER TO CHAPTER "TEST PROCEDURE").
NOTE: C/T FUSE AND MONITOR SWITCH ARE
REPLACED AS AN ASSEMBLY
7
R-200BK R-200BW
TURNTABLE MOTOR
The turntable motor rotates the turntable located on the bottom of the oven cavity, so that the food on the turntable is cooked evenly. The turntable may turn in either direction.
COOLING FAN MOTOR
The cooling fan motor drives a blade which draws external cool air. This cool air is directed through the air vanes surrounding the magnetron and cools the magnetron. This air is channelled through the oven cavity to remove steam and vapours given off from the heating foods. It is then exhausted through the exhausting air vents at the oven cavity.
MAGNETRON THERMAL CUT-OUT
The thermal cut-out located on the top of the oven cavity is designed to prevent damage to the magnetron if an over heated condition develops in the tube due to cooling fan failure, obstructed air guide, dirty or blocked air intake, etc. Under normal operation, the thermal cut-out remains closed.
However, when abnormally high temperatures are reached within the magnetron, the thermal cut-out will open at 257˚F (125˚C), causing the oven to shut down.
C/T FUSE
1. The C/T fuse blows when the contacts (COM-NO) of the primary interlock relay (RY2) and secondary interlock switch remain closed with the oven door open and when the monitor switch closes.
2. If the wire harness or electrical components are short­circuited, this C/T fuse blows to prevent an electric shock or fire hazard.
3. The C/T fuse, located on the top of the oven cavity, is designed to prevent damage to the oven by fire. If the food load is overcooked, by either error in cook time or defect in the timer, the C/T fuse will open.
Under normal operation, the C/T fuse remains closed. However, when abnormally high temperatures are reached within the oven cavity, the C/T fuse will open at 248˚F (120˚C), causing the oven to shut down or when the electric currents beyond 13A flow, the C/T fuse will open.
TROUBLESHOOTING GUIDE
Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.
When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Procedure "section.
IMPORTANT: If the oven becomes inoperative because of a blown C/T fuse, check the monitor switch, primary
interlock relay (RY1), door sensing switch and secondary interlock switch before replacing the C/T fuse. If C/T fuse is replaced, the monitor switch must also be replaced. Use part FFS-BA020WRK0 as an assembly.
IMPORTANT: Wherever troubleshooting is performed with the power supply cord disconnected. It may in, some cases, be
necessary to connect the power supply cord after the outer case has been removed, in this event,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.
6. After that procedure, reconnect the power supply cord.
When the testing is completed,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Reconnect the leads to the primary of the power transformer.
5. Reinstall the outer case (cabinet).
6. Reconnect the power supply cord after the outer case is installed.
7. Run the oven and check all function.
8
TEST PROCEDURE
POSSIBLE CAUSE
AND
DEFECTIVE PARTS
RE CK ABC
CK = Check / RE = Replace
D
EFFGHRE RE CK
I/J
CKCK CK K
R-200BK R-200BW
CONDITION
OFF CONDITION
COOKING CONDITION
PROBLEM
Home fuse blows when power cord is plugged into wall receptacle.
C/T fuse blows when power cord is plugged into wall receptacle.
C/T fuse blows when the door is opened. Fan motor does not operate. (All other
electric components function.) Oven lamp does not light at all. (All other
electric components function.) Turntable motor does not operate. (All other
electric components function.) Oven does not go into cook cycle when
Light Up Dial is turned Oven seems to be operating but little or
no heat is produced in oven load. (Food incompletely cooked or not cooked at all at end of cook cycle.)
Oven goes into a cook cycle but ex­tremely uneven heating is produced in oven load (food).
Oven lamp, turntable motor and fan mo­tor do not operate.
SHORT IN POWER CORD
SHORT OR OPEN WIRING
MAGNETRON
POWER TRANSFORMER
H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE CAPACITOR
MAGNETRON THERMAL CUT-OUT
PRIMARY INTERLOCK SYSTEM
SECONDARY INTERLOCK SWITCH
MONITOR SWITCH
C/T FUSE
OVEN LAMP OR SOCKET
COOLING FAN MOTOR
TURNTABLE MOTOR
CONTROL UNIT OR RELAY
WRONG OPERATION
LOW VOLTAGE
DIRTY OVEN CAVITY
FOIL PATTERN ON PWB.
PROCEDURE
LETTER
A MAGNETRON ASSEMBLY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check across the magnetron filament leads should indicate less than 1 ohm.
5. To test for a shorted magnetron, connect the ohmmeter leads between the magnetron filament leads and chassis ground. This test should indicate an infinite resistance. If there is little or no resistance the magnetron is grounded and must be replaced.
6. Reconnect all leads removed from components during testing.
7. Reinstall the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
MICROWAVE OUTPUT POWER
The following test procedure should be carried out with the microwave oven in a fully assembled condition (outer case fitted).
TEST PROCEDURES
COMPONENT TEST
9