Sharp PD3151F Datasheet

PD3151F
PD3151F
Position Sensitive Detector with Location Hole (PSD*)
Features Outline Dimensions
1. Easy high accuracy positioning owing to location hole Detecting portion pattern positional accuracy : ± 0.1 mm
2. Thin, compact package
1.67
5
0.8
6
R0.4
3. Visible light cut-off type
Applications
1. Cameras
* PSD:Position Sensitive Detector
φ 0.9
1.905
1.905
123
5.0
Chip positional accuracy : ± 0.1 mm, Rotational deviation : ± 2 ˚
1
2 3 5 6
4
6.0
7.0
7.9
Detector face
3.0
0.97
1.5 Shape of detector portion
1 Anode A
4
2 Cathode 3 Cathode 4 Anode B 5 Cathode 6 Cathode
1.95
4.0
1.95
1.5
1.5
1.5
0.8
0.15
Absolute Maximum Ratings
(Ta=25˚C)
Parameter Symbol Rating Unit Reverse voltage Operating temperature Storage temperature
*1
Soldering temperature
*1 For MAX. 3 seconds in the soldering area
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
V
T
opr
T
stg
T
sol
R
30
-25to+85
-40to+85 + 260
V ˚C ˚C ˚C
Soldering area
PD3151F
Electro-optical Characteristics
Parameter Symbol Conditions MIN. TYP. MAX. Unit Reverse voltage Dark current Collector current Terminal capacitance Peak sensitivity wavelength Sensitivity wavelength range Response time Resistance between electrodes Error of position detection Sensitivity Forward voltage
*2 IL=I1+I
*3 Test circuit for response time is shown below.
*4 75% area from detecting portion center to the edge of detecting portion
2
where, I and I are collector current of A1 and A2 respectively.
12
Ev : Illuminance by CIE standard light source A (tungsten lamp)
Input
Laser diode
λ=830nm
Definition of error of position detection : Error of position detection of each incident light position is defined by the following formula, if electrical center position is I = I .
Error of position detection (µm) =
L : Length of light detector surface =1.5mm
LI 2
RL= 1k V
R
1-I2
x
- Incident light position (µm)
I1+I
2
V
I
*2
C
λ
λ
*3
t
r
Rie V
*4
---±25µm R - - 0.5
V
V
R
IR=10µA30--V
R
V
d
I
L
t
P
=1V - - nA
R
VR= 1V, EV= 1000 lx - µ A V
= 1V, f= 10kHz
R
---
-
, t
VR= 1V, RL=1k -30µs
f
= 1V, Va= 0.5V k
R
-
I = 1mA
Input
Output
F
trt
90% 10%
f
F
(Ta=25 ˚C)
1.5
10
6
10
-30pF nm nm
770
940
-
1130
5
320
400
-
12
480
-
A/W
-
V1.0
Fig. 1 Spectral Sensitivity
120
100
80
60
40
Relative sensitivity (%)
20
0 600 700 800 900 1000 1100 1200
Wavelength λ (nm)
Fig. 2 Dark Current vs. Ambient Temperature
-6
10
-7
10
-8
10
d
-9
10
(I A)
-10
10
-11
10
Dark current
-12
10
-13
10
-14
10
0-25 255075100
Ambient temperature Ta(˚C)
VR=1V
Loading...
+ 1 hidden pages