Note)Characteristics shown in diagrams are typical values. (not assurance value)
HS series
HY series
0.5
2
1
3
5
10
20
50
100
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4
Forward Current vs. Forward Voltage(Note)
Forward voltage VF(V)
Forward current IF(mA)
(Ta=25˚C)
10
20
50
200
100
500
1000
-20 0 20 40 60 10080
Luminous Intensity vs. Ambient Temperature(Note)
Ambient temperature Ta(˚C)
Relative luminous intensity(%)
(IF=20mA)
1
2
5
200
100
20
50
10
500
0.1 0.2 0.5 1 2 5 10 20 50
Luminous Intensity vs. Forward Current(Note)
Forward current IF(mA)
Relative luminous intensity(%)
(Ta=25˚C)
5
10
30
50
100
300
500
1/50 1/20 1/10 1/5 1/2 1
Duty Ratio vs. Peak Forward Current
Duty ratio DR
Peak forward current IF(mA)
(Ta=25˚C)
0
10
20
30
40
50
60
-25 0 25 50 75 85 125100
Peak Forward Current Derating Curve
Ambient temperature Ta(˚C)
Peak forward current IFM(mA)
0
10
20
30
40
50
60
-25 0 25 50 75 85 125100
Peak Forward Current Derating Curve
Ambient temperature Ta(˚C)
Peak forward current IFM(mA)
0
10
20
30
40
50
60
-25 0 25 50 75 85 125100
Forward Current Derating Curve
Ambient temperature Ta(˚C)
Forward current IF(mA)
0
10
20
30
40
50
60
-25 0 25 50 75 85 125100
Forward Current Derating Curve
Ambient temperature Ta(˚C)
Forward current IF(mA)
0.1
0.5
1.0
5.0
10
50
100
1.0 1.2 1.4 1.6 1.8 2.0 2.4 2.62.2
Forward Current vs. Forward Voltage(Note)
Forward voltage VF(V)
Forward current IF(mA)
(Ta=25˚C)
1.0
5.0
10
50
100
500
1000
-20 0 20 40 60 80 120100
Luminous Intensity vs. Ambient Temperature(Note)
Ambient temperature Ta(˚C)
Relative luminous intensity(%)
(Ta=25˚C)
1.0
5.0
2.0
10
20
50
100
200
500
1000
0.1 0.2 0.5 1 2 5 10 20 50
Luminous Intensity vs. Forward Current(Note)
Forward current IF(mA)
Relative luminous intensity(%)
(Ta=25˚C)
1.0
5.0
2.0
10
20
50
100
200
500
1/50 1/20 1/10 1/5 1/2 1
Duty Ratio vs. Peak Forward Current
Duty ratio DR
Peak forward current IFM(mA)
(Ta=25˚C)
119
(Notice) ¡
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
(Internet) ¡Data for sharp's optoelectronic/power device is provided for internet.(Address http://www.sharp.co.jp/ecg/)