Maximum wet-bulb temperature at 39℃ or less. (Ta>40℃) No condensation.
【*2】The Vcc power supply capacity must use the one of 2A or more.
The V
DD power supply capacity must use the one of 3A or more.
【*3】 There is a possibility of causing deterioration in the irregularity and others of the screen and the display
fineness though the liquid crystal module doesn't arrive at destruction when using it at 65~70℃.
There is a possibility of causing the fineness deterioration by the prolonged use in the (high temperature)
humidity environment (60% or more).
【*4】In the operating temperature item, the low temperature side is the ambient temperature regulations.
The high temperature side is the panel surface temperature regulations.
Page 10
6.Electrical Characteristics
6-1.TFT-LCD panel driving
LD-24604C- 7
T
=+25℃
a
Parameter
Supply voltage3.0
Symbol
V
Current dissipation
Input voltage width for LVDS receiver
Permissive input ripple voltage
Differential input
Threshold voltage
High
Low
V
V
Input voltage
Input reak current
Terminal resistor
ConditionMin.
CC
I
Vcc=3.3V-
CC
V
L
RP
TH
V
TL
V
IH
V
IL
I
OH
I
OL
R
T
【*1】 On-off conditions for supply voltage
0.9 V
CC
0.1 V
CC
V
CC
Data
Back light
t
1
t
2
ON
t
5
OFFOFF
Typ.
3.3
300400
0
-2.4
--200
--
V
-100
CM
2.1
-
-
-10
-
0.9 V
t
t
6
0.1 V
3
t
4
-
-
-0.8
-
-
100-
CC
CC
100μs<t1≦ 10ms
500ms ≦ t
200ms ≦ t
Max.
3.6
V
+100
CM
-
400
+10
0<t
0<t
1s≦ t
2
3
4
5
6
Unit
V
mA
V
mV
P-P
mV
mV
V
V
μA
μA
Ω
≦ 20ms
≦1s
Remark
【*1】
【*2】
Vcc = 3.3V
=+1.2V
V
CM
【*3】
【*4】-
V
=
+3.3V【*4】
I2
V
=0V 【*4】
I2
Differential input
Vcc-dip conditions
・
V
CC
Vth<VCC≦V
min
td≦ 10ms
Vmin
V
th
t
d
Hsync/Vsync need not be input so that this model may drive only by the ENAB signal.
・
Even if Hsync/Vsync is input, it doesn't become a malfunction.
The relation between the data input and the backlight lighting will recommend the above-mentioned input sequence.
・
When the backlight is turned on before the panel operates, there is a possibility of abnormally displaying.
The liquid crystal module is not damaged.
Vth=2.5V
=3V
V
min
【*2】 Current dissipation
・V
Vcc-dip conditions should also follow the On-off
conditions for supply voltage
<V
CC
RGB RGB RGBRGBRGB
GS0 GS1 GS2
th
・・・
GS62 GS63
Typical current situation : 64-gray-bar pattern
( Vcc=+3.3V、fck = 40MHz、Ta=25℃ )
【*3】 V
: LVDS common mode voltage
CM
【*4】 RL/UD , SELLVDS
Page 11
6-2.LED backlight
V
Parameter
LD-24604C- 8
Ta=+25℃
SymbolMin.Typ.Remark
Max.
Unit
Supply voltage
VDD10.212.0
I
DD1-600
Current dissipation
DD2--
I
Permissive input ripple voltage
High voltageV
RP_BL
IH_BL1
XSTABY
IL_BL1
Low voltageV
High voltageV
V
IH_BL2
V
VBR
Low voltageV
PWM frequency
IL_BL2
PWM200.0-1k
PWM duty100.0DPWM10.0-
Life timeL
【*1】 On-off conditions for supply voltage
0.9 VDD
0.1 VDD
VDD
XSTABY
t8
t7t9
【*1】
【*2】
【*3】
【*3】
【*4】
【*4】
【*4,5】f
【*4,5】
【Reference】
【*6】
7≦ 200ms
8≦
--V
2.4-V
-
2.1
--V
13.8
750
12
200.0VDD=+12.0
VDD
-
-
0.2
VDD
0.8
mV
V
mA
mA
P-P
Hz
%
(50,000)
--
(Module)
0.9 VDD
0.1 VDD
t10
h
100μs ≦ t
0ms ≦ t
0ms ≦ t9≦
200ms ≦ t10≦
PWM
ON
VBR
Back light
(LED)
t11t12
OFFOFF
【*2】 Current dissipation
Typ. value: V
Max. value: V
△2【*3】 Backlight ON/OFF signal
DD= +12V、Duty=100%
DD= +10.2V、Duty=100%
(connected by the pull-down resistor of 10kΩ)
△2【*4】 PWM signal (connected by the pull-down resistor of 10kΩ)
【*5】 PWM
PWM = 1/t14
f
VBR
Duty 10% : Min. Luminance (0%:LED OFF)
Duty 100% : Max. Luminance
Luminance changes in proportion to the duty ratio. (t
13≧500μs)
When the frequency slows, the display fineness might decrease.
10ms ≦ t11≦
0ms ≦ t12≦
t13
t14
【*6】 Luminance becomes 50% of an initial value. (Ta=25℃, PWM=100%)
Page 12
7.Timing characteristics of input signals
7-1.Timing characteristics
LD-24604C- 9
Max.Unit
42.0MHz
Clock
Parameter
Frequency
Symbol
1/Tc
Min.
35.0
Typ.
40
94010561395clock
Horizontal period
Horizontal period (High)
TH
THd
23.5
26.4
800800
39.9μs
800clock
ENAB
Vertical Frequency
Vertical period (High)
TV
628
-
TVd600
600
666line798
16.7-ms
600line
【*1】 In case of using the long vertical period, the deterioration of display quality, flicker etc. may occur.
TH
THd
ENAB
DATA
(R,G,B)
800800
12
Remark
【*1】
Tc
600599600
ENAB
TV
7-2.Input Data Signals and Display Position on the screen
RGBR
( 1, 1 )
GB
( 2, 1 )
D(1,1) D(2,1) D(3,1)D( 800,1)
12
TVd
D(1,2) D(2,2)
D(1,3)
R
G B
D(1,600)D( 800 , 600 )
Page 13
8.Input Signals, Basic Display Colors and Gray Scale of Each Color
LD-24604C- 10
Basic ColorGray Scale of RedGray Scale of GreenGray Scale of Blue
fig.2-2 Measuring method of contrast, luminance, response time,
and Chromaticity.
Panel center(θ=0°)
TFT-LCD module
Fig.2 Optical characteristics measurement method
Page 15
LD-24604C- 12
【*1】Definitions of viewing angle range:
θ22
Normal line
θ11
θ21
θ12
6 O'clock
【*2】Definition of contrast ratio:
Luminance with all pixels white
Contrast (CR)=The contrast ratio is defined as the following.
Luminance with all pixels black
【*3】Definition of response time:
The response time is defined as the following figure and shall be measured by switching the input signal for
"black" and "white".
Time
τ
White
r
White
100%
90%
(Relative Value)
Photodetector Output
10%
0%
τ
d
Black
【*4】This shall be measured at center of the screen.200400600 pixel
【*5】Definition of white uniformity:
White uniformity is defined as the following with five measurements.
(①~⑤)150
2
Maximum luminance of 5 points(①~⑤).
δ
=
w
Minimum luminance of 5 points(①~⑤).
×100%
5
3
1
4
300
450
pixel
Page 16
LD-24604C- 13
10. Handling Precautions
a ) Be sure to turn off the power supply when inserting or disconnecting the cable.
b ) Since the front polarizer is easily damaged, pay attention not to scratch it.
c ) Wipe off water drop immediately. Long contact with water may cause discoloration or spots.
d ) When the panel surface is soiled, wipe it with absorbent cotton or other soft cloth.
e ) Since the panel is made of glass, it may break or crack if dropped or bumped on hard surface.
Handle with care.
f ) Since CMOS LSI is used in this module, take care of static electricity and injure the human earth
when handling. Observe all other precautionary requirements in handling components.
g ) Since there is a circuit board in the module back, stress is not added at the time of a design assembly.
Please make it like. If stress is added, there is a possibility that circuit parts may be damaged.
h ) It causes an irregular display and the defective indication, etc., when always put constant pressure
on the back of the module.
Please do not make the structure to press the back of the module.
i ) Do not expose the LCD panel to direct sunlight. Lightproof shade etc. should be attached
when LCD panel is used under such environment.
j ) Connect GND to stabilize against EMI and external noise.
k ) When handling LCD modules and assembling them into cabinets, please avoid that long-terms storage
in the environment of oxidization or deoxidization gas and the use of such materials as reagent, solvent,
adhesive, resin, etc. which generate these gasses, may cause corrosion and discoloration of the modules.
Do not use the LCD module under such environment.
l ) Liquid crystal contained in the panel may leak if the LCD is broken. Rinse it as soon as possible
if it gets inside your eye or mouth by mistake.
m ) Be careful when using it for long time with fixed pattern display as it may cause accidential image.
n ) Adjusting volume have been set optimally before shipment, so do not change any adjusted value.
If adjusted value is changed, the specification may not be satisfied.
o ) If a minute particle enters in the module and adheres to an optical material, it may cause display
non-uniformity issue, etc. Therefore, fine-pitch filters have to be installed to cooling and inhalation
hole if you intend to install a fan.
p) The polarizer surface on the panel is treated with Anti-Glare for low reflection. In case of attaching
protective board over the LCD, be careful about the optical interface fringe etc. which degrades display
quality.
q ) Notice : Never take to pieces the module , because it will cause failure.
Please do not peel off the Black tape pasted to the product.
An abnormal display by changing in quality of the polarizing plate might occur regardless of contact
r)
or no contact to the polarizing plate, because of epoxy resin (amine system curing agent)
that comes out from the material and the packaging material used for the set side, the silicon adhesive
(dealcoholization system and oxime system), and the tray blowing agents (azo-compound), etc.
Please confirm adaptability with your employed material.
Page 17
11.Packing form
a) Piling number of cartons :MAX.4
b) Package quantity in one carton: 30pcs
c) Carton size(TYP):520mm(W) × 370mm(D)×315mm(H)
LD-24604C- 14
d)
Total mass of one carton filled with full modules(30pcs): MAX 26kg
12.Reliability test items
No.
1
2
3
4
5
6
7
8
Test item
High temperature
storage test
Low temperature
strage test
High temperature
& high humidity
operation test
High temperature
operation test
Low temperature
operation test
Vibration test
(non-operating)
Shock test
(non-operating)
Thermal shock
Ambient temperature 80℃ 240H
Ambient temperature -30℃ 240H
Ambient temperature 40℃、Humidity 95% RH 240H
(No condensation.)
Panel surface 70℃ 240H
Ambient temperature -15℃ 240H
<Sin wave>
Frequency :10~57Hz/Vibration width (one side) :0.076mm
:57~500Hz/Gravity:9.8m/s2
Sweep time:11minutes
Test period :3H(X,Y,Z direction 1H)
Max. gravity:490m/s2 Pulse width:11ms
Direction:±X,±Y,±Z Test period :1time/1direction
-30℃[0.5h]~80℃[0.5h]/50cycles
test
Conditions
Remark
【Note1】
【Note1】
【Note1】
【Note1】
【Note1】
【Note1】
【Note1】
【Note1】
【Note1】 Under the display quality test conditions with normal operation state, these shall be no change
which may affect practical display function. (normal operation state:Temperature:15~35℃,
Humidity:45~75%, Atmospheric pressure:86~106kpa)
Page 18
13.Others
13-1.Lot No Label:
A)Module serial label
The label that displays SHARP・Model No.( LQ121S1LG88)・Lot No. is stuck on the back of the module.
LD-24604C- 15
△1
SHARP logo
Model No.
Lot No.
Lot No display method(Figure and alphabet) :Lotno.iscomposedof20characters.
Productionyear
Production month
Production day
Serialnumber
13-2.Packing box Label:
The label that displays ①Model number( LQ121S1LG88) ②Lot number ③Quantity of module is stuck
on the packing box. Moreover, the display of bar code also applies to this.
社内品番:
Lot No. : (1T) 2012. 06. 26**
Quantity : (Q)30 pcs
ユーザー品番 :
シャープ物流用ラベルです。
(4S) LQ121S1LG88
Barcode(①)
Barcode(②)
Barcode(③)
A right picture is written to the packing box of module for the RoHS restriction.
R.C.(RoHs Compliance)means these parts have corresponded with the RoHs directive.
※
This module corresponds from the first sample to RoHS Directive.
① Model number( LQ121S1LG88)
② Lot number (DATA)
③ Quantity of module
Our management product number might be filled
(Example: LQ121S1LG88A etc.)
R.C.
The figure below is written under the SHARP logo of the packing box about the production country.
13-3.
The ozone-depleting substances is not used.
13-4. If any problem occurs in relation to the description of this specification , it shall be resolved
through discussion with spirit of cooperation.
Page 19
14.Storage conditions
】
Environmental condition range of storage temperature and humidity
Temperature 0 to 40 degrees Celsius
Relative humidity 95% and below
【Note
Winter time temperature 5 to 15 degrees Celsius humidity , 85% and below
Direct sun light
Atmospheric condition
Prevention of dew
Storage period
Within above mentioned conditions, maximum storage period should be one year.
Please refer below as a mean value of the environmental conditions.
Summer time temperature 20 to 35 degrees Celsius humidity , 85% and below
Please maintain within 240 hours of accumulated length of storage time, with conditions of 40 degrees
Celsius and room humidity of 95%.
Please keep the product in a dark room or cover the product to protect from direct sun light.
Please refrain from keeping the product with possible corrosive gas or volatile flux.
Please store the product carton either on a wooden pallet or a stand / rack to prevent dew.
Do not place directly on the floor. In addition, to obtain moderate ventilation in between the pallet’s
top and bottom surfaces, pile the cartons up in a single direction and in order.
Please place the product cartons away from the storage wall.
LD-24604C- 16
Page 20
LD-24604C- 17
Fig. 1 : LQ121S1LG88 OUTLINE DIMENSIONS
Page 21
LD-24604C- 18
Fig.3 : PACKING FORM
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.