SHARP LPE230 Technical Report

Date: Feb. 23, 1996
LASER PRINTER: JX-9210
(Part changes)
1.A CHANGE TO THE DR IDLE GEAR
2.A CHANGE TO THE PARTS OF THE FUSING UNIT
3.A CHANGE TO THE FD COVER
1. A change to the DR idle gear.
1.Model name: JX-9200/9210
2.General: In order to correct a pitch error, we have changed the DR idle gear.
No. : LPE-230
3.Description: Before the change After the change DR idle gear NGERH0072GCZZ NGERH0072GCZ1 (Gear B (small toothed gear) has been rotated +0.4, and gear A has been made thicker.)
4.Action: From November, 1995 production on.
2. A change to the parts of the fusing unit.
1.Model name: JX-9200/9210
2.General: Parts have been added to and taken from the fusing unit, as indicated below.
3.Description: No. Part name Before the change After the change
. Separation spring A MSPRD0227GCZZ MSPRD0227GCZ1 Reason Change in shape to prevent the separation pawl from rotating when paper jams
. Screws XBPSN30P05K0 0 XBPSN30P06 KS0 Reason Correction to the part guide
. Polyslider — LX-WZ5004BCZZ Reason Two polysliders have been added to prevent the delivery roller from jamming
. Polyslider — LX-WZ2009SCZZ
SHARP CORPORATION Printer and Scanner Division
1/3
Orange
C
Reason A polyslider has been added to prevent strange noises coming from the FU idle gear
Added 2 polysliders ±0.5 LX-WZ5004BCZZ
A change to the shape of separation spring A MSPRD0227GCZ1
Change to the M3x6 screws(SW, W) XBPSN30P06KS0
Added polyslider (ø10xø6, Α±0.4) LX-WZ2009SCZZ
4.Action: From the first lot on.
2/3