Date: Feb. 8, 1994
LASER PRINTER: JX-9460PS
No. : LPE-185
1.PCU ROM CORRESPONDANCE.
2.CHANGE IN SHAPE OF TC TERMINAL SPRING B.
3.CHANGE IN CAPACITOR OF THE PS CIRCUIT BOARD.
1. PCU ROM correspondance.
1.Model name: JX-9460 / PS
2.General: The 1-chip CPU used in the PCU circuit boards of the models listed above has been
changed from the OPT version to a mask.
Note: this change does not affect the ROM version.
3.Description: <<Old CPU>> <<New CPU>>
VHIM37451SP03 VHIM37451S320
(V U11 labeled OTP) (V U11 unlabeled mask)
4.Action: 1993 November production.
2. Change in shape of TC terminal spring B.
1.Model name: JX-9400 / 9600 / 9460 / PS / 9660 / PS
2.General: The shape of TC terminal spring B has been changed to improve operationability.
3.Description:
Changed TC Terminal
spring B.
Old
Attachment screw X.
MSPRT0120GCZZ MSPRT0120GCZ1
New
Attachment screw X.
SHARP CORPORATION Printer and Scanner Division
1/2
Orange
C
4.Action: From 1993 November production.
3. Change in capacitor of the PS circuit board.
1.Model name: JX-96PS1, JX-9460PS, JX-9660PS
2.General: The C5 capacitor (39pF) of the optional PS circuit board for models JX-9660 and
JX-9460 has been changed from a radial capacitor to a chip capacitor.
3.Description: The C5 39pF radial capacitor has been changed to a chip capacitor
(VCCCTV1HH390J).
Attachment location of
the 39pF chip capacitor.
4.Action: From 1993 October production.
Ref.
Model
No.
JX-9460
1
JX-9460PS
JX-9400
9460/PS
2
9600/PS
9660/PS
JX-9660PS
3
JX9460PS
JX96PS
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. C urr e nt t y pe c a n be u s ed i n p la ce of new ty pe .
New ty pe cann ot be us ed i n place of curr ent type .
3. C urre nt ty pe cann ot be used i n place of new ty pe.
New t y pe c a n be u sed in pla c e of c u rr en t ty p e.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
name
Version P/G No.
9 -42 VHIM37451SP03 VHIM37451S320 AX CPU (Mask) ’93/11 1 IC4
4 -14 MSPRT0120GCZZ MSPRT0120GCZ1 AC
All
13 -28 VCCCPU1HH390J VCCCTV1HH390J AA
!
2/2
Current parts New parts
Parts code Parts code
5. Interchangeable if replaced with same types of
relate d parts in use .
6. Others.
Price
rank
Parts name
TC Terminal
spring B
Capacitor
(50WV 39pF)
Effec-
Inter-
tive
change-
time
Mid-
’93/11
’93/10 6 C5
Note
ability
3