Sharp LL-S201A User Manual

LL-S201A
Operating Manual of Service Tool
Version 1.6/1.7
2013/06/28
1. Introduction .................................................................................................................. 5
1.1. TOOL OPERATING ENVIRONMENT ................................................................ 5
1.2. INSTALLATION PROCEDURES ........................................................................ 5
1.3. USE INSTRUCTIONS .......................................................................................... 5
1.4. CONFIRMATION OF THE SERVICE TOOL VERSION ................................... 6
2. CONNECTION and LIMITATION .............................................................................. 7
2.1. CONNECTION ..................................................................................................... 7
2.2. LIMITATION ......................................................................................................... 7
2.3. USAGE AT MULTI DISPLAY .............................................................................. 7
3. COMPOSITION OF THE SERVICE TOOL SCREEN ............................................... 8
4. MAKE A CONNECTION BETWEEN LL-S201A AND PC ........................................ 9
5. QUICK SUMMRY OF THE FEATURE .................................................................... 11
5.1. Firmware version up (Version UP) ..................................................................... 11
5.2. Setting the destination of model (MODEL) ....................................................... 11
5.3. Changing the serial number (Serial Number) ................................................... 11
5.4. Setting the LED back light usage time (Back Light Usage Time) ................. 11
5.5. Backup and restore the White Balance settings (White Balance Settings) ..... 11
5.6. Factory reset (Factory Reset) ............................................................................. 11
5.7. Start aging(Aging) .......................................................................................... 11
5.8. Power LED lighting test (Power LED Test) ....................................................... 11
5.9. Display Test pattern (Test Pattern) ................................................................... 11
5.10. Touch panel adjustment (TC Adjustment) ..................................................... 11
6. FIRMWAER VERSION UPVers ion U P) .............................................................. 12
6.1. Overview .............................................................................................................. 12
6.2. Storing position of version up data .................................................................... 12
6.3. Scalor part version up ......................................................................................... 13
6.3.1. Notes during the upgrade ............................................................................... 15
6.3.2. Tips ................................................................................................................... 15
6.4. Touch part version up ......................................................................................... 16
6.4.1. Note during upgrade ....................................................................................... 17
6.5. Simultaneous Upgrade (Scaler Part + Touch Part) ........................................... 18
6.6. NOTES AND LIMITATION ................................................................................ 18
6.6.1. Scaler part version up ..................................................................................... 18
6.6.2. Touch part version up ...................................................................................... 18
7. SETTING THE DESTINATION (MODEL) .............................................................. 19
7.1. Overview .............................................................................................................. 19
7.2. How to operate .................................................................................................... 19
8. SETTING THE SERIAL NUMBERSerial Number .......................................... 20
8.1. Overview .............................................................................................................. 20
8.2. How to operate .................................................................................................... 20
8.3. Important notice ................................................................................................. 20
9. SETTING USAGE TIME OF LED BACK LIGHTBack Light Usage Time ..... 21
9.1. Overview .............................................................................................................. 21
9.2. How to operate .................................................................................................... 21
10. WHITE BLANCE STTINGS BACKUP / RESTOREWhite Balance Settings
22
10.1. Overview .......................................................................................................... 22
10.2. How to operate (Backup / Restore) ................................................................. 22
10.4. Default setting file ........................................................................................... 24
10.5. Note .................................................................................................................. 24
11. MISCELLANEOUS FEATURE ............................................................................. 25
11.1. Factory resetFactory Reset ...................................................................... 25
11.1.1. Overview ................................................................................................... 25
11.1.2. Detail of data Initialized (portion related to user ) ................................. 26
11.1.3. Important notice ....................................................................................... 26
11.2. Aging (Aging) ............................................................................................... 27
11.2.1. Overview ................................................................................................... 27
11.2.2. Start and stop ........................................................................................... 27
11.3. Power LED lighting test (Power LED Test) ................................................... 28
11.3.1. Overview ................................................................................................... 28
11.3.2. Start and stop ........................................................................................... 28
11.4. Test patternTest Pattern .......................................................................... 29
11.4.1. Overview ................................................................................................... 29
11.4.2. Start and stop ........................................................................................... 29
11.5. Touch Panel Controller Adjustment ............................................................... 31
11.5.1. Overview ................................................................................................... 31
11.5.2. Operation flow .......................................................................................... 31
11.5.3. Check the normality of touch panel ........................................................ 31
11.5.4. Setting-Limitation .................................................................................... 32
11.5.5. Check Pen Touch Accuracy ...................................................................... 33
11.5.6. Calibration Touch Position ....................................................................... 36
11.5.7. Drawing Check ......................................................................................... 38
Summary of Changes
2013/02/04 Version 1.1
Add full range warning dialog 6.3
Add chips for file selection 6.3.2
2013/02/05 Version 1.2
Replace the new UI image
Add Touch Panel Controller adjustment 11.5
Modify Test pattern feature 11.4
2013/02/08 Version 1.3
Replace the new UI image
2013/02/26 Version 1.4
Replace the new UI image
Modify Scaler version up function 6.3
(Scaler version up is possible also under “Limited range”)
Modify Touch Panel Controller adjustment 11.5
2013/05/17 Version 1.5
Modify Touch Panel Controller adjustment 11.5
2013/06/28 Version 1.6
Modify the confirmation screen at Firmware version up 6.3 and 6.4.
1. Introduction
1.1. TOOL OPERATING ENVIRONMENT
Windows XP / Windows Vista / Windows 7 / Windows 8 Support 32bit OS (this tool can work under 64bit OS also, but it is not assured) Login with the administrator’s right
1.2. INSTALLATION PROCEDURES The service tool is delivered one archive file. Although a tool can be extracted to arbitrary folders, please do not change the directory composition and file name in which the tool is extracted.
1.3. USE INSTRUCTIONS Execute “ServiceTool.exe” in the folder where the service tool is extracted.
Memo: In the case of Windows Vista or Windows 7, the window of “User Account
Control” is displayed as shown below, so you need to click [Allow].
1.4. CONFIRMATION OF THE SERVICE TOOL VERSION Launch the ServiceTool, and check the service tool version which is displayed at the title bar .
2. CONNECTION and LIMITATION
2.1. CONNECTION
AC adopter
1. Connect the PC by USB cable and the image cable (Display port / HDMI).
2. Turn on a monitor.
3. Launch the service tool.
2.2. LIMITATION To upgrade the scalar firmware, it is necessary to set the PC graphics board to its default color settings.
2.3. USAGE AT MULTI DISPLAY When using this tool with a notebook PC, it is necessary to set a resolution setting for
Display Port (DP)
/ HDMI
USB
LL-S201A to 1920x1080. Therefore, if the setting of the multi-screen is “Duplicate Display”, please change the display setting to “Extended Display” with resolution as 1920x1080, and set LL-S201A as primary display. Moreover, the service tool should be operated at the LL-S201A side.
3. COMPOSITION OF THE SERVICE TOOL SCREEN
1. Button
The action is executed. A message window comes out if needed.
2. Edit box
It is a box for the character input from keyboard. Action is decided by pushing the button related to the box concerned after an input.
3. Check box
Action is executed by choosing a box of item to check, and pushing the VersionUP button.
4. Radio button
One is chosen from more than one candidate. Action is executed by choosing and pushing the ModelChange button.
4. MAKE A CONNECTION BETWEEN LL-S201A AND PC
In order to operate each function, it is necessary to change LL-S201A and PC into
connection state. The start-up state of ServiceTool is “Not Connected”, so please push
the “Connect” button first.
When the cable is not connected, or when there is no response from a display, the
message of the purport as “connection error” is displayed.
If the cable is connected normally, and there is no response from a display, the main
board may not be operating.
A following cause can be considered as a cause by which the below error message is
displayed by USB connection.
cable is not connected
board is out of order
power supply of display is not on
When PC connection is made normally, following information is displayed.
1. The current version number (Version UP)
2. The destination of model (MODEL)
3. Serial number (Serial Number)
4. Usage time of LED back light (Back Light Usage Time)
Memo: The service mode of the touch display can also check the above information.
V1 version of scaler V2 version of touch controller(ARM) V3 version of touch USB controller(NXP) M destination of model
(0:Japan, 1:North America, 2:EU, 3:EU(2)
N serial number BT usage time of LED back light(0 h to 65535 h)
5. QUICK SUMMRY OF THE FEATURE
5.1. Firmware version up (Version UP)
The controller software of LL-S201A is updated if necessary.
5.2. Setting the destination of model (MODEL)
The destination setting is set or changed in case of board exchange and the repair.
5.3. Changing the serial number (Serial Number)
The proper serial number of LL-S201A is written in case of the board exchange and the
repair.
5.4. Setting the LED back light usage time (Back Light Usage Time
The usage time of back light is set in case of board exchange or LCD module exchange.
5.5. Backup and restore the White Balance settings (White Balance Settings)
The white balance preset value currently recorded on the set is read, and data is
recorded on PC. The white balance adjustment value of display can be inherited by
exchanging board after recording on PC.
5.6. Factory reset (Factory Reset)
The current preset value is returned to a factory-shipments state.
5.7. Start agingAging
An aging pattern is displayed and the display is aged.
5.8. Power LED lighting test (Power LED Test)
The Power LED of LL-S201A is blinked on and off.
5.9. Display Test pattern (Test Pattern)
In case of exchange, etc. Display a test pattern on LCD module, and check position
alignment and image quality.
5.10. Touch panel adjustment (TC Adjustment)
In case of exchange touch panel, adjust the touch panel setting.
6. FIRMWAER VERSION UPVersion UP
6.1. Overview
The LL-S201A is composed of the scaler part and the touch-panel part, and is upgraded
by rewriting three firmwares. Upgrade of the scaler part rewrites software displaying a
bit map image on a display. On the other hand, upgrade of the touch-panel part rewrites
software via USB. Upgrade of two blocks can be set up individually. In addition, after
the software of the touch panel is rewritten, it is necessary to insert power cycle. Please
once pull out the AC/DC adaptor and put it again.
6.2. Storing position of version up data
In order to execute the version up, it is necessary to put data on the specified folder.
Please put a file on the folder of the following relative paths from the folder which
installed the program of the service tool.
ServiceTool
ServiceTool.exe
Firmware.bmp (for scaler version up)
TP_Verup
TP_Verup.exe
writeFile
ARM
ranger_ROM_r6760_WTTL.bin (for touch controller)
NXP LPCXpresso11U24_usbhid-0117-D0-1 次用.bin
(for touch USB controller)
6.3. Scalor part version up
1
2
3
1. Change PC and LL-S201A into connection state. Version information is displayed
when it is connected normally.
2. Select check box for Scaler.
3. Push the VersionUP button, the following message box will be displayed.
Loading...
+ 28 hidden pages